Lenovo RD230 manual Opening the retention tab

Page 64

This section provides instructions on how to remove the riser card with a PCI card installed.

To remove the riser card, do the following:

Note: Use any documentation that comes with the riser card and follow those instructions in addition to the instructions in this section.

1.Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all power cords from electrical outlets and disconnect all cables that are connected to the server.

2.Remove the server cover. See “Removing the server cover” on page 42.

3.Disconnect any cables from the PCI card or any cables that impede access to the riser card.

4.Open the retention tab that secures the PCI card, which is installed on the riser card.

Figure 22. Opening the retention tab

58ThinkServer RD230 Types 1043, 1044, 4010, and 4011: Hardware Maintenance Manual

Image 64
Contents ThinkServer RD230 Hardware Maintenance Manual Page Hardware Maintenance Manual First Edition June Copyright Lenovo Contents Appendix A. RAID battery card Important Safety Information About this manualSafety statements To Connect To DisconnectDo not About this manual Statement Important information about replacing RoHS compliant FRUs Page Features General informationSpecifications RAID supportReliability, availability, and serviceability Software programsEasyStartup EasyManagePage Troubleshooting tables DiagnosticsDVD drive problems General problems Hard disk drive problemsIntermittent problems Keyboard, mouse, or pointing-device problems Memory problems Microprocessor problems Monitor problems Optional-device problems Power problems Serial port problems Universal Serial Bus USB port problems Software problemsSolving power problems Solving Ethernet controller problems Solving undetermined problems Event logsSystem event log Viewing event logs without restarting the serverCondition Action Diagnostic LEDs on the front control panel Onboard debug digitronPage Front view Locating parts, controls, LEDs, and connectorsRear view Front control panel State Color DescriptionHard disk Drive LED Description Green Amber Locating server components Locating parts on the system boardLocating major parts on the system board Jumper Position Description CmosLocating connectors on the backplane Shows the connector locations on the backplanePage Guidelines Installing, removing, or replacing hardwareBasic guidelines System reliability guidelines Inspecting for unsafe conditions Guidelines for trained service techniciansGuidelines for servicing electrical equipment Working inside the server with the power on Handling static-sensitive devices Removing the server cover Removing the server coverInstalling or removing a memory module Memory module installation rulesDimm slot One Dimm Two DIMMs Three DIMMs Four DIMMs Dimm slot Two DIMMs Four DIMMs Six DIMMs Eight DIMMsInstalling a memory module CPU0 Dimm CHC0 CPU1 Dimm CHA1 CHA0 CHB0Removing a memory module Opening the retaining clips of the memory slotRemoving or installing internal drives Removing the memory moduleRemoving the optical drive Removing the optical driveInstalling the optical drive Removing the optical drive retention tabInstalling, removing, or replacing hardware Installing the retention tab and connecting the cables Installing the optical drive Removing a hot-swap hard disk driveRemoving a 3.5-inch hard disk drive Installing a hot-swap hard disk drive Removing the hard disk drive tray assembly Installing a 3.5-inch hard disk drive Installing or removing the riser card Installing the riser cardInstalling the riser card Removing the riser cardOpening the retention tab Installing or removing a PCI card Installing a PCI cardInstalling a PCI card into the slot on the riser card Removing a PCI cardRemoving or installing the Ethernet card Removing the Ethernet cardInstalling the Ethernet card Installing, removing, or replacing hardware devices Removing or installing the system board batteryRemoving the system board battery Installing the system board batteryRemoving or installing the RAID controller Installing the system board batteryInstalling the RAID controller Removing the RAID controllerPage Bottom view Installing the battery card assembly Removing or installing the heat sink assembly Removing the heat sink assemblyInstalling the heat sink assembly Removing the heat sink assemblyInstalling the heat sink assembly Removing or installing the microprocessor Removing the microprocessorInstalling the microprocessor Lifting the handle Removing or installing the system fans Removing the system fansInstalling the system fans Removing or installing the power supply Seven ports that secure the system fansRemoving the power supply Removing the screws that secure the power supply Installing the power supply Disconnecting the power supply cablesInstalling, removing, or replacing hardware Installing the screws to secure the power supply Removing or installing the system board Removing the system boardRemoving the nine screws that secure the system board Installing, removing, or replacing hardware Installing the system board Installing the nine screws that secure the system boardCompleting the parts replacement Installing the server coverConnecting the cables Turning on the serverUpdating the server configuration Turning off the serverConnecting external devices Page Parts listing, RD230 Types 1043, 1044, 4010, Replaceable server components CRU part Number FRU part Index Description TierParts listing, RD230 Types 1043, 1044, 4010, and 4011 CRU part Number FRU part Index Description Tier CRU part Number FRU part Index Description Tier CRU part Number FRU part Index Description Tier CRU part Number FRU part Index Description Tier Power cords Parts listing, RD230 Types 1043, 1044, 4010, and 4011 Power cords, Type Power cords, Type Page Configuring the server Using the Setup Utility programStarting the Setup Utility program Introduction of the Bios itemsAmibios Option DescriptionAcpi C2 Submenus under the Mass Storage Controller Configuration Option Description Items and options with BMC configuration Items and options without BMC configurationSub-item Option Description PEF SupportItems under the Boot menu Restore on AC Power LossUsing passwords Exiting the Setup Utility programPassword considerations Setting, changing, or deleting a passwordRAID controllers Documentation DVDSetup and configuration Using the ThinkServer EasyStartup programBefore you use the EasyStartup DVD Configuring RAID Typical operating system installationRAID information Configuring the onboard Sata software RAIDStarting the Intel Matrix Storage Manager program Creating the RAID volume Deleting the RAID volumeRebuilding the RAID volume Configuring the Gigabit Ethernet controllerUsing the EasyUpdate Firmware Updater program Updating the firmwareInstalling the ThinkServer EasyManage program Page Battery life and data retention time Appendix A. RAID battery card assemblyBBU name Data retention time Page Appendix B. Getting help and technical assistance Before you callCalling for service Using other servicesPurchasing additional services Lenovo product service Page Appendix C. Notices 127Trademarks Important notesProduct recycling and disposal Particulate contamination Contaminant LimitsBattery return program Türkiye EEE Yönetmeliğine Uygunluk BeyanıGerman Ordinance for Work gloss statement For CaliforniaUnited Kingdom telecommunications safety requirement Industry Canada Class a emission compliance statementAvis de conformité à la réglementation d’Industrie Canada European Union EMC Directive conformance statementGermany Class a compliance statement Appendix C. Notices Korea Class a warning statement Index CRUProblems Page Page
Related manuals
Manual 32 pages 3.46 Kb

RD230 specifications

The Lenovo RD240 and RD230 are key players in the realm of enterprise-class servers, leveraging advanced technologies to deliver efficiency, reliability, and performance. These servers are designed to cater to the demands of small to medium-sized businesses, providing robust solutions for various workloads.

The Lenovo RD240 is a 2U rack server that features dual-socket support for Intel Xeon processors. This capability allows it to handle intensive computational tasks seamlessly, making it ideal for virtualized environments and database management. Equipped with up to 512GB of DDR3 memory, the RD240 ensures high memory bandwidth and reduced latency, improving overall system responsiveness.

In terms of storage, the RD240 supports a versatile range of options, with configurations allowing for up to twelve 3.5-inch hard drives or a combination of SSDs and HDDs. This flexibility enables businesses to tailor their storage solutions based on performance and capacity needs. Additionally, the server includes integrated RAID options, which enhance data protection and availability.

On the other hand, the RD230 is a compact 1U rack server that prioritizes space efficiency without compromising on performance. Like its larger counterpart, the RD230 supports dual Intel Xeon processors, but its design focuses on providing a more streamlined solution for environments with limited rack space. With support for up to 128GB of RAM, the RD230 can efficiently handle various applications, from web hosting to application serving.

Both servers are equipped with advanced management tools, such as the Lenovo XClarity Controller, which simplifies system monitoring and maintenance. This allows IT administrators to deploy updates, monitor hardware health, and manage resources with ease, leading to minimized downtime and optimized performance.

Furthermore, Lenovo places a strong emphasis on energy efficiency, ensuring that both the RD240 and RD230 have features like power management and cooling technologies. These innovations reduce their carbon footprint while lowering operating expenses, making them attractive choices for environmentally-conscious businesses.

In summary, the Lenovo RD240 and RD230 servers offer a blend of performance, flexibility, and efficient management, catering to the diverse needs of modern enterprises. With their robust features and reliable characteristics, they stand as dependable solutions for businesses looking to enhance their IT infrastructure while supporting future scalability.