Setting
Remote control
The eight different remote control codes (Code
The same code should be set on both the projector and the remote control. For example, operating the projector in “Code 7”, the remote control code also must be switched to “Code 7”.
To change the code for the projector;
Select a remote control code in this Setting Menu.
To change the code for the remote control;
Check the Reset Switch to "Use position" in the compartment lid on the back of the remote control.
And then while holding down the MENU button, press and release the IMAGE ADJ. button the number of corresponding times you would like to set the number of the remote control code for the projector. (See page 16)
To reset the code for the remote control;
Slide the Reset Switch to "Reset position" in the compartment lid on back of the remote control.
RC sensor
Select a location of the infrared remote receiver of the remote control. See “Remote Control Receivers and Operating Range” on page 15 for details.
Both | Activate both the front and back receiver. |
Front | Activate only the front receiver. |
Back | Activate only the back receiver. |
Power management
For reducing power consumption as well as maintaining the lamp life, the Power management function turns off the projection lamp when the projector is not used for a certain period.
If the input signal is interrupted and no button is pressed for more than 30 seconds, the timer display with “No signal” appears. It starts the countdown until the lamp is turned off. The countdown time can be set between 1 and 30 minutes.
Use the Point 7 8 buttons to set the countdown timer.
Select one of the following options:
Ready . . . . When the lamp has been fully cooled down, the READY indicator starts blinking. In this condition, the projection lamp is turned on if the input signal is reconnected or any button on the side control or remote control is pressed .
Shutdown . . When the lamp has been fully cooled down, the power is turned off.
Off . . . . . . . Power Management function is off.
✔Note:
•Factory default is “Ready: 5 min.”
•When the shutter is closed while the Power management function is working, the Power management function is released.
Remote control
When pressing the SELECT button at Remote control, the Remote control code menu appears.
Power management
Time left before the lamp is off
Press the SELECT button at Power management and the dialog box appears. Use the Point 7 8 buttons to choose one of the three options.
Press the Point d button to select the timer, and then use the Point 7
8buttons to set the timer
52