Hitachi SJ-DG instruction manual Table of input mode, Off, Type Code BIN PAC, Type Code BCD DIV

Page 13

CHAPTER 4 SETTING

It is possible to select input mode by combination of dip switch and rotary switch on the option printed board. Table 4-4 shows table of input mode.

Table 4-4 Table of input mode

 

 

 

Rotary

 

 

 

 

 

Acceleration and

Torque

Position

Dip switch

Setting frequency

 

 

limit

switch

 

 

deceleration time setting

setting

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE

CODE

 

 

 

 

 

Setting resolution

 

 

Switch No.

Setting

0.01Hz

0.1Hz

1Hz

Rate

 

0.01sec

0.1sec

1sec

1%

1pulse

1

2

code

 

 

 

 

 

 

 

 

 

 

 

 

 

PAC

0

O

 

 

 

 

 

 

 

 

 

 

 

1

 

O

 

 

 

 

 

 

 

 

 

 

(One

 

 

 

 

 

 

 

 

 

 

 

2

 

 

O

 

 

 

 

 

 

 

 

 

time

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

O

 

 

 

 

 

 

 

 

input

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

O

 

 

 

mode at

 

 

 

 

 

 

 

 

 

BIN

 

5

 

 

 

 

 

 

 

 

 

 

 

OFF)

 

 

 

 

 

 

 

 

 

 

(Binary

 

6

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

input at

 

 

0

O

 

 

 

 

O

 

 

 

 

OFF)

 

 

1

 

 

 

 

 

O

 

 

 

/

 

 

2

 

 

 

 

 

 

 

O

 

 

BCD

 

DIV

3

 

 

 

 

 

O

 

 

 

 

(BCD

 

4

 

O

 

 

 

 

O

 

 

 

 

(Dividing

 

 

 

 

 

 

 

 

input at

 

5

 

 

 

 

 

 

 

O

 

 

 

input

 

 

 

 

 

 

 

O

O

ON)

 

6

 

 

 

 

 

O

 

 

 

mode at

 

 

 

 

 

 

 

 

 

 

 

7

 

 

O

 

 

 

O

 

 

 

 

 

ON)

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

O

 

 

 

 

 

 

 

A

 

 

 

O

 

 

O

 

 

 

 

 

 

B

 

 

 

 

 

 

 

O

 

 

Precaution O shows input mode set by switch setting. Make sure not to set switch setting except O because they are for adjustments of factory.

(Viewpoint of table of input mode)

Example 1) In one time input mode, switch setting which sets setting frequency by 1Hz resolution and binary input.

TYPE

 

CODE

1

 

2

2

BIN

 

PAC

 

 

Example 2) In two dividing input, switch setting which sets setting frequency with 0.1Hz resolution and BCD input, and in case of setting acceleration and deceleration time by BCD input, 0.1sec.resolution.

TYPE

 

CODE

1

 

2

2

BCD

 

DIV

 

 

7

Image 13
Contents SJ300/L300P Series Hitachi InverterRevision History Table Safety Precautions Otherwise, there is a danger of electric shock and/or fire Otherwise, there is a danger of connecting errorOtherwise, there is a danger of electric shock Otherwise, there is a danger of fireSafety Precautions Page Warranty of the Product Inquiry of the Product and Warranty for the ProductInspection Upon Unpacking Outline of the ProductInstallation of option printed board Installation Method of Printed BoardPlcb Terminal Assignment of Digital Input Option Board Connection to Programable Controller Case of using external power sourceApplicable Wiring Specification of TerminalSpecification of terminal Initial Setting Condition of Printed Board Position of Setting SwitchSetting of Inverter Input Mode by DIP Switch and Rotary SwitchOFF Table of input modeType Code BIN PAC Type Code BCD DIVPrecautions AT Setting of Switch ONE Time Binary Input FunctionONE Time BCD Input BIN PACBIN DIV TWO Dividing Binary InputBCD DIV TWO Dividing BCD InputData Input Timing Classification CodeTiming AT ONE Time Input MO DE Table of classification codeTiming AT TWO Dividing Data Input 2 Timing chart of two dividing data inputBCD