Lanier T 6055 manual Fire Fighting Measures, Accidental Release Measures, Stability and Reactivity

Page 2

 

 

MATERIAL SAFETY DATA SHEET

Page 2

of

CP-239

 

 

Section 5: Fire Fighting Measures

 

Suitable extinguishing media: CO2, dry chemical, foam or water.

Extinguishing media which may not be used for safety reasons: none

This material will burn in case of fire. The decomposition products are CO, CO2, and Nox. Avoid inhalation of smoke. Special protective equipment for fire fighters: none

UEL: n/a

LEL: n/a

 

Section 6: Accidental Release Measures

Sweep up or clean up with an approved toner vacuum.

 

Section 7: Handling and Storage

Special Handling:

none

Special Storage:

No special storage requirements for safety reasons. Store in a cool dry place.

 

 

 

Section 8: Exposure Control and Personal Protection Information:

Respiratory Protection: none required under normal use.

Eye Protection: none required under normal use.

Hand Protection: none required under normal use.

Skin Protection: none required under normal use.

Section 9: Physical and Chemical Properties

CHARACTERISTICS:

 

 

 

Appearance:

Black

Melting point:

N/a

Form:

Fine powder

Vapor pressure:

n/a

Odor:

Practically odorless

Vapor density:

n/a

Solubility in Water:

Negligible

Evaporation rate:

n/a

Specific gravity:

1.1

Boiling point:

n/a

Section 10: Stability and Reactivity

Conditions to avoid: none

Materials to avoid: none

Stability: Stable

Hazardous decomposition products: CO, CO2, and NOx when burned.

 

Section 11: Toxicological Information:

Acute oral toxicity (rat) LDLO: Over 5.0 g/kg

Ames Test result: Negative

Carcinogenicity: In 1996, the IARC reevaluated carbon black as a GROUP 2B carcinogen (possible human carcinogen). This evaluation is given to carbon black for which there is inadequate human evidence, but sufficient animal evidence. The latter is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at a level that induce particle overload of the lungs. Studies performed in mice have not demonstrated an association between carbon black and lung tumors. Moreover, a two-year cancer bioassay using a typical toner preparation containing carbon black demonstrated no association between toner and tumor development in rats.

Section 12: Environmental / Ecological Information

None

Section 13: Disposal Consideration

Waste material may be dumped or incinerated under conditions, which meet all federal, state and local environmental regulations.

Section 14: Transportation Information

None

Section 15: Regulatory Information

None

Section 16: Miscellaneous Information

Information on this data sheet represents our current data and best opinion as to the proper use in handling of this product under normal conditions. On

the basis of the data available to us, this product is not a dangerous substance. One should, however, observe the usual precautionary measures for dealing

with chemicals.

Image 2
Contents Chemical Product and Company Information Lanier Worldwide, IncEmergency Telephone 800 Black TonerExposure Control and Personal Protection Information Fire Fighting MeasuresAccidental Release Measures Physical and Chemical PropertiesMaterial Safety Data Sheet