NEC NDA-30007-003 manual Application Configuration, Application Characteristics Both Components

Page 7
Chapter 2 Application Configuration

Conference Room Scheduler Installation Guide

Application Configuration

Chapter 2 Application Configuration

Conference Room Scheduler is configured into the APM system using the Add function of the Application Configuration option on the APM System Administration menu:

1.Enter the APM option from the APM Platform Management Menu.

2.Enter the System Administrator password at the APM password screen.

3.Enter the Application Configuration option from the System Administration menu.

This section contains the information that should be entered to the configuration file for Conference Room Scheduler. The following components must be configured:

Conf_Room_Sch

The component application that maintains the real-

 

time database and interacts with the user at the

 

Dterm.

Conf_Room_Sch_Rpt – The component application that displays or prints

the real-time database.

For specific instructions on what these parameters mean and how to make these entries, use the APM Operations Manual.

Step 1 – Application Characteristics (Both Components)

In the APM Application Configuration option, make the entries shown below for the components:

Parameter

Description

Conf_Room_Sch

Conf_Room_Sch_Rpt

 

 

 

 

OAI Application

Indicates whether or not (Yes

 

 

 

or No) this component

 

 

 

communicates with the

Y

N

 

NEAX2400 using OAI

 

 

 

processes.

 

 

 

 

 

 

CRT Application

Indicates whether or not (Yes

 

 

 

or No) this component requires

 

 

 

a terminal screen that is of the

N

Y

 

same type as the one used by

 

 

 

the APM.

 

 

 

 

 

 

Communication Queue

Indicates whether or not (Yes

 

 

 

or No) this non-OAI

 

 

 

application needs an IPC queue

N

N

 

to communicate with other

 

 

 

processes.

 

 

 

 

 

 

NDA-30007 Revision 3.0

Page 3

Image 7
Contents NDA-30007-003 Revision January Stock # AN OPEN APPLICATION INTERFACE OAI INSTALLATION GUIDENEC America, Inc CONFERENCE ROOM SCHEDULERNEC America, Inc LIABILITY DISCLAIMERCopyright Chapter 1 - Introduction TABLE OF CONTENTSPage Chapter 2 - Application ConfigurationThis Page Left Blank Conference Room Scheduler Installation GuideDatabase Requirements Software InstallationApplication Configuration ChapterChapter ASSET MASTER INSTALLATION REQUIREMENTSApplication Configuration Mat AssignmentsStep 1 - Application Characteristics Both Components Chapter 2 Application ConfigurationConfRoomSch Message Step 2 - Primary Configuration Parameters Both ComponentsConfRoomSchRpt make no entryStep 3 - Facilities ConfRoomSch only Step 4 - Secondary OAI Configuration Parameters ConfRoomSch onlyConfRoomSch User-defined Parameters Step 5 - User-Defined Parameters Both ComponentsConfRoomSch Rpt User-defined Parameters Page Step 3 - Create Chapter 3 Database RequirementsStep 1 - Create Step 2 - BuildConference Room Database Information InstructionsFile Refer to Step 5 - User-Defined Parameters Employee Identification Database InformationBoth Components on page 6 for sorting Page Chapter 4 MAT Assignments Manual, the NEAX2400 IMS Job Specification Manual, and the NEAX2400IMS Programming Manual AKYD COMMAND Assignment of Dterm Function Key AOKC COMMAND Assignment of OAI Key CodesScheduler communication with Conference Room Scheduler Page Conference Room Scheduler Installation GuideThis Page Left Blank MAT Assignments