Icom DS-100 instruction manual All ships, Distress relay

Page 19
<Message contents>
Routine to group From: DS-100 SN3 F3E/G3E Simplex CH88
No Information <A/aData clear>
<Message contents>
<A/aData clear>
Urgency to All ships From: DS-100 SN3 F3E/G3E simplex
CH 14

WHEN RECEIVING A CALL 3

• All ships

qPush [CALL], then push [] several times to select ‘Re- ceived calls’, then push [ENT].

wSelect ‘Other message’, then push [ENT].

eSelect ‘All ships call’, then push [ENT].

Push [Y] or [Z] to scroll the message.

Push [A/a] to clear the message.

• Distress

qPush [CALL], then push []

several times to select ‘Re- ceived calls’, then push [ENT].

wSelect ‘Other message’, then push [ENT].

eSelect ‘Distress’, then push [ENT].

Push [Y] or [Z] to scroll the message.

Push [A/a] to clear the mes- sage.

• Distress relay

qPush [CALL], then push [] several times to select ‘Re- ceived calls’, then push [ENT].

wSelect ‘Other message’, then push [ENT].

eSelect ‘Distress relay’, then push [ENT].

Push [Y] or [Z] to scroll the message.

Push [A/a] to clear the mes- sage.

<Message contents>

Distress relay From: DS-100 SN3 Distress ID:

2345678 To all ships Fire,Explosion Distress Time & Pos Time: UTC 12:34 Pos.: Lat 12°34’N

Lon 123°45’W

<A/aData clear>

15

Image 19
Contents DS-100 If disregarded, inconvenience only. No risk Personal injury, fire hazard or electricShock may occur Equipment damage may occurPage Table of Contents Front panel Panel DescriptionFunction display GPS IndicatorTime Zone Indicator Position IndicatorCall Procedure Distress call/Regular operation Entry Position/Time Individual call Distress call to shipsAll ships call Group callAfter receiving acknowledgement call When no acknowledgement is receivedDisplay example and operation When Receiving a CallWhen receiving a DSC call To receive a DSC callPush ENT, then the oper When receive a Distress callWhen receiving a Position request When receiving an All ships callWhen receiving a Postion reply When receiving a Distress Relay ACK When receiving a Distress ACK When receiving a group callDistress message Received message RCV MSGIndividual call Other messagesGroup call Distress All shipsDistress relay Distress acknowledgement Distress relay acknowledgement q Push CALL, then push √Add an address ID SET-UPSelect ‘Set-up’ Address IDAdd a group ID Delete address IDDelete a group ID Mmsi check Offset timeBrightness ContrastConnection diagram Connection and InstallationsRear panel description Supplied accessoriesOverhead Mounting MountingInternational channels VHF Marine Channel ListSpecifications Specifications and OptionsOptions Dimensions Instructions Supplied accessoriesMB-75 Page Template Page 0560 Count on us

DS-100 specifications

The Icom DS-100 is a sophisticated digital signal processor designed to enhance the performance of communication systems. As a testament to Icom's commitment to innovation, the DS-100 comes equipped with a variety of features suited for both amateur and professional radio operators. Its robust design integrates advanced technologies that significantly improve audio clarity and reduce background noise, making it a valuable tool in various communication scenarios.

One of the main features of the DS-100 is its digital noise reduction capability, which employs sophisticated algorithms to analyze and filter out unwanted background sounds. This results in clearer audio transmission and reception, enabling users to communicate more effectively even in challenging environments. The unit also offers adjustable settings, allowing users to fine-tune the noise reduction levels according to their preferences and the specific conditions they are operating in.

Another notable characteristic of the DS-100 is its wide frequency range compatibility, allowing it to function seamlessly with various Icom transceivers. This versatility ensures that operators can utilize the DS-100 across different frequency bands, making it an ideal choice for multi-band communication. The device is also designed for ease of use, featuring a user-friendly interface that simplifies configuration and operation.

The DS-100 is built with durable materials, emphasizing Icom's reputation for quality and longevity. Its compact and lightweight design makes it portable, enabling operators to take it on their travels or deploy it in the field with ease. This rugged construction is complemented by advanced thermal management systems, ensuring reliable performance even under extended usage or in varying environmental conditions.

In addition to its technical features, the Icom DS-100 supports various connectivity options, including USB and other standard interfaces. This allows for easy integration with computers and other devices, providing enhanced flexibility for data transfer and system upgrades.

Overall, the Icom DS-100 stands out as a powerful tool for enhancing communication efficiency and clarity. Its combination of advanced digital signal processing technology, robust design, and versatile functionality make it an essential addition for anyone serious about effective radio communications. Whether in emergency services, amateur radio operations, or professional use, the DS-100 delivers unparalleled performance that meets the demands of modern communications.