NEC 2000 IPS manual Pn-Iptb Ipt, PN-4VCTI 4VCT

Page 339

 

 

 

 

 

 

 

Chapter 16 Wireless System

 

 

 

 

 

 

 

 

 

 

 

WCS Required Equipment (Cont.)

 

 

 

 

 

 

 

EQUIPMENT

 

 

DESCRIPTION

 

QTY

 

 

REMARKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10BASE-T Cable

 

 

10BASE-T/100BASE-TX Cable

 

As required

 

 

For Q931a Roaming

 

 

(TIA/EIA category

 

 

between ETHER card and Ethernet

 

 

 

 

over IP Trunk

 

 

3 or larger)

 

 

Cable Length:

 

 

 

 

(Virtual IPT) Note

 

 

100BASE-TX

 

 

Maximum 100 m (328 ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable (TIA/EIA

 

 

 

 

 

 

 

 

 

 

category 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Router

 

 

 

 

As required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN-AP00-B (DBM)

 

 

Roaming Data Base Module card

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN-IPTB (IPT)

 

 

IP Trunk card

 

1-8

 

 

For Q931a Roaming

 

 

 

 

 

 

 

 

 

 

over IP Trunk

 

 

PN-4VCTI (4VCT)

 

 

4-channel CODEC card

 

1-32

 

 

 

 

 

 

 

 

 

(Physical IPT)Note

 

 

 

 

 

 

 

 

 

 

 

 

IPTRK BUS CA

 

 

Set of 3 BUS Cables between IPT and

 

1-32 sets

 

 

 

 

 

 

 

 

4VCT cards

 

 

 

 

 

 

 

 

 

 

Length: 0.1 m (0.33 ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10BASE-T Cable

 

 

10BASE-T/100BASE-TX Cable

 

As required

 

 

 

 

 

(TIA/EIA category

 

 

between IPT card and Ethernet

 

 

 

 

 

 

 

3 or larger)

 

 

Cable Length:

 

 

 

 

 

 

 

100BASE-TX

 

 

Maximum 100 m (328 ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable (TIA/EIA

 

 

 

 

 

 

 

 

 

 

category 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Router

 

 

 

 

As required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN-AP00-B (DBM)

 

 

Roaming Data Base Module card

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PZ-M606-A (ETHER)

 

 

Ethernet Control Card

 

1

 

 

For Short Message

 

 

 

 

 

 

 

 

 

 

Notification (OAI)

 

 

10BASE-T Cable

 

 

10BASE-T/100BASE-TX Cable

 

1

 

 

 

 

 

 

 

 

 

 

 

 

(TIA/EIA category

 

 

between ETHER card and Ethernet

 

 

 

 

 

 

 

3 or larger)

 

 

Cable length:

 

 

 

 

 

 

 

100BASE-TX

 

 

Maximum 100 m (328 ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable (TIA/EIA

 

 

 

 

 

 

 

 

 

 

category 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The SPN-AP00B DBM-C is required when accommodating 257 or more PSs.

UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide

Page 16-17

Issue 6

 

Image 339
Contents May Univerge Neax 2000 IPSLiability Disclaimer NEC Unified Solutions, IncInaset Chapter OAI Application Software DevelopmentIsdn Basic Rate Interface BRI Univerge Neax 2000 IPS Documentation List Overview of NEC IntroductionInvention Age Industrial AgeElectronic Age Components Information AgeWorldwide Leadership People CommunicationsSocial Contributions Global ResourcesEducation AssetsInnovation CommunityDevelopment ActivitiesDALLAS, Texas NEC Unified Solutions, IncAreas Major ProductCompetitive Benefits and Advantages Vertical MarketsIntroduction Introduction Univerge Neax 2000 IPS Pstn MaintenanceStation to Station Connection Ccis ConnectionReduced Hardware with IP based Architecture Office Data Backup EnhancementVarious Installation Methods Built-in DRS Device Registration Server on MPDual MP System DC/DC Power Supply forUniversal Slot Extended Application Processor AP Port CapacitySystem Outline for Remote PIM Univerge Neax IPS DMLAdvantages of Remote PIM Characteristics of the Univerge Neax IPS DM/IPS DML/IPS DMRIP PAD Stand Alone System CapacityIPS System Capacity Single MP System Capacity Per PIM PIM1 PIM2 PIM3 PIM4 PIM5 PIM6 PIM7IPS System Capacity Single MP System cont’d Capacity Per PIM 2M-AMI IPS System Capacity Dual MP System Capacity Per PIMIPS System Capacity Dual MP System, Cont’d Capacity Per PIM 8LC IPS DM/IPS DML System CapacityCapacity Per MC IP-PADBuilt-in Router Max card per Site Dtmf Sender IP Remote Network Capacity Total System Capacity Main plus RemoteCapacity IPS DMR Capacity DTI IsdnIPS Pimmj As Remote PIM Capacity Voice and Data Switching System ArchitectureHardware Architecture Application Processors Hardware DesignFusion of RAM and ROM Programs Main Processor MP with Integrated FunctionalityAnalog/Digital Telephones IntegrationUnified Circuit Card SN716 Attendant ConsolePIM Univerge Neax 2000 IPS System ConfigurationModules Module and Installation HardwareSingle MP System Dual MP SystemInstallation Hardware Installation HardwareAbbrev Description Quantity Name Code Qty Remarks Battery BackupInternal Cabling CablingExternal Cabling Maintenance Administration Terminal MAT RS-232CCable for AP00 Name Code Qty Remarks External Alarm DisplayBuilt-in SMDR/MCI on MP SMDR/PMS/Hotel Printer/MCI with AP00B MRC-CIPS DM/IPS DML Modular Chassis MC Univerge Neax IPS DM/IPS DML/IPS DMR System ConfigurationModular Chassis 2 Modular Chassis IPS DMR Modular Chassis MCModular Chassis MC and Bracket Modular Chassis MC InstallationSystem Power Supply and Cooling Fan Software Architecture System PackagesPKG IPS Univ IPS DM/DML Expansion Module 1E DM to Univ DM Upgrade KitUniv IPS DML IP SYS PKG Univ IPS DM IP SYS PKG-EUniv IP Remote PIM-B IPS IP Remote PIM PackagesDescription Remarks Univ IPS DMR SYS PKG-ECapacity Option used w/Key Keeper Software Keys/LicensesDescription Remarks Generic Program Key Keeper Parent Capacity OptionName Code Remarks System HighlightsProcessors Main Processor MPFirmware Processor FP PN-CP24-C PN-CP31-C PN-CP27-ADAT Function Application Processor APApplication Processor AP Cards AP CardMtbf Mttr Reliability and Availability Chart Description FitReliability and Availability Mean Time Between Failures MtbfReliability Description Availability Fit Reliability and Availability ChartFit YearsReliability Description Availability Reliability Calculation Mean Time To Repair MttrReliability Calculations Availability CalculationsBhca Busy Hour Call Attempts System TrafficTraffic Load Busy HourTraffic Capacity In Erlang For TDM Circuits Calculation ProcedureNumber of Trunks Traffic Capacity per Line For TDM CircuitsErlang B Table Traffic Internal Call Distribution External Line TrunkCOT UCD PEG Count Wireless PEG CountPEG Count Trunk PEG CountPayload size for Virtual IPT Number of Voice Channels per IP TrunkCcis Point-to-Multipoint VoIP H.323IP PAD Calculation Number of extensions 100 IP PAD CalculationNumber of extensions 120 200 208 264 300 320 376 432 IP PAD CalculationSystem Specifications Cable Length Transmission Characteristics For TDM CircuitsLine Conditions Loop Resistance including Opposite End ResistanceDescription Specifications Receiving Sending Rotary Dial Pulse and Dtmf SignalingRotary Dial Signal Dtmf SignalMulti-frequency Compelled MFC R2 Signal Audible Tones Frequency Interruption Audible Tones and Ringing SignalRinging Signal Dimension and WeightOpen Industry Standards Univerge Neax IPS DM/IPS DML/IPS DMR System SpecificationsSystem Specifications EMCLAN interface transmission modes Remarks IP SpecificationsFAX 10BASE-T/100BASE-TXDepartment of Defense Compliance System ComplianceHipaa Summary Hipaa CompliancePage Module/Installation Hardware Equipment ListEquipment Name Function Name Equipment Name Remarks Common Control Cards Circuit CardsPN-PW00 Extpwr PN-CP31PN-CP15 EtherApplication Processor Cards Application Processor Card Name and FunctionFunction Name Port Remarks Application Processor Cards Qsig SPN-AP00B DBM-C APLine/Trunk LT Cards Line/Trunk LT CardsPN-4DLCM SPN-2ILCAPN-8DLCL DeskconSPN-16VCTAA IP PAD-EPAD-C PZ-24IPLAPN-2ODTA PN-8COTQPN-4COTB PN-4COTGSPN-4VCTI-A PN-2DATAPN-TNTA SPN-IPTB-APN-RTA SPN-4CSIAPage Dterm Series E Terminals Station EquipmentTerminal Line Up Dterm Series i TerminalsDterm Extenders Wireless HandsetInaset Dterm IP Soft PhonesSpecification for Analog Terminals Physical FeaturesDescriptions of the Dterm IP Terminals Convergence Features Call Handling FeaturesDCR-60-1 BK Console DCR-60-1 WH Console Descriptions of TerminalsDTR-2DT-1 BK TEL DTR-2DT-1 WH TEL DTR-4D-1BK TEL DTR-16LD-1 BK TEL DTR-16LD-1 WH TELSpecification Standard featuresCable Length Standard With AC Adapter Terminal OptionsDterm Series E Soft keys Standard featuresDescriptions of Series E Multi-line Digital Terminals Description of Series E Multi-line Digital Terminals APR-U Dterm Series E Accessories & AdaptersADA-U HFU-UIPW-2U ELC ACA-UWMU-U WMU-WDSS Dterm Series E Specifications2DT 16D 32D Add-OnLoop Resistance and Distance Long Loop circuit built-in Dterm Series E Line ConditionsDterm Cordless Terminals Dterm Cordless II DTR-4R-2 BKOptions Options Dterm Cordless Lite II DTH-4R-1 BKPlantronics CT Cordless SpecificationsAdditional Applications Inaset ApplicationsWM-RL Unit Inaset Terminal Line UPInaset Basic Network Capability PBX System RequirementsDterm PS III Options Dterm PS III Wireless HandsetFeatures Key Features and BenefitsPresence/Status Links with PC applicationsInternet Link Real Time CommunicationApplication Collaboration Voice RecordingLine Display Voice Quality AlarmOne Key Operation Call Log ExportPause into Dialing string Client PC specificationOne Touch Button in Compact Mode PB tone sendingDterm Extenders PBX Specification Must be peer to peer IP enabledDterm SP30 Softphone Parts List Software/Licenses/AccessoriesService Conditions for Dterm Analog EXT Page LT/AP TrunkingType of Trunks Type of Trunk Circuit PackageTrunk Parameters Trunk Card SpecificationsPN-AUCA SPN-BRTC PN-4RSTBA-911 MF Sender PN-8RSTG Dtmf ReceiverPN-4RSTBA MF Receiver for T1 MF ANI PN-4RSTC ID Number ReceiverIPS Trunking Capacity System Capacity System Trunking CapacityIPS DM/DML Trunk Capacity Least Cost Routing LCR Six Digit Least Cost RoutingRoute Restriction Class RSC Toll Restriction Digit Toll RestrictionPriority Restriction Class Page Attendant Console SN716 Attendant Answering PositionSN716 Deskcon General Features SN716 Deskcon Exclusive FeaturesDeskcon Exclusive Features Face Layout of the SN716 Deskcon Location Key or Lamp Full Basic Key/Lamp Number Designation Functions and use of Keys and Lamp IndicationsLDN LCD Interface ’ty Remarks Power Options SN716 SpecificationsBusiness Attendant System BAS BAS Benefits Business Attendant System Directory Business Attendant System Speed Dials Pad Business Attendant System Additional FeaturesBusiness Attendant System Ccis Network Information Hardware Requirements Business Application EnvironmentPage Password Entry System AdministrationSystem Administration Customer Administration Terminal CATMaintenance Administration Terminal MAT Mach Script Editor PBX Configuration WizardTraffic Management MATWorX PC RequirementsMinimum Requirements Recommended Service Conditions System DiagnosticsSelf Diagnostic/System Messages Remote MaintenanceGeneral Service Conditions MP Program DownloadMP Download Process Equipment Comments Program Download Service ConditionsProgram Changeover Service Conditions Required HardwareMA4000 Management System Business/Hotel/Data Feature List Feature DescriptionsBusiness/Hotel/Data Feature List Descriptions Snmp Business/Hotel/Data Feature Descriptions Attendant Assisted Calling Attendant Camp-on Full and Semi- automaticAttendant Console SN716 Deskcon Attendant Lamp Check Attendant Overflow Attendant Delay AnnouncementAuthorization Code Attendant LockoutAutomatic Camp-on Automatic Call Distribution ACDBack Up CPU Automatic RecallAutomatic Wake-up Background MusicBrokers Call Call BackCall Forwarding Call Park Caller ID Class Call PickupCall Redirect Call TransferCheck In / Check Out Class of ServiceCamp-on Centrex CompatibilityConsecutive Speed Dialing Conference Six/Ten PartyConference 32 Party Group CallDial By Name Delayed RingingDiagnostics Data Line SecurityDirect Station Selection/Busy Lamp Field DSS/BLF Console Direct Inward System Access DisaDirect Inward Termination DIT Direct Outward Dialing DODDistinctive Ringing Do Not DisturbDtermIP Elapsed Call TimerFax Arrival Indicator Dterm AssistantForced Account Code Feature Activation from Secondary ExtensionFlexible Line Key Assignment Flexible Numbering PlanHold Individual Attendant AccessHands-free Answerback Hands-free Dialing and MonitoringLeast Cost Routing 3/6 Digit IP Enabled DtermInternal Zone Paging with Meet-Me Last Number RedialMessage Reminder Miscellaneous Trunk AccessMessage Center Interface MCI Message RegistrationMP Program Download FTP Mobility AccessNight Service Modem over IPOff-hook Alarm No CID Call RoutingOff-Premises Extensions Pad Lock Pooled Line AccessPower Failure Transfer Optical InterfaceAutomatic Idle Return Resident System Program Reserve PowerRemote Hold Remote PIM over IPSet Relocation Security AlarmSingle Digit Feature Access Codes Save and RepeatTie Line Tandem Switching System Clock Setup by Station DialingTenant Service Terminal Login via NATTrunk Queuing Outgoing Timed Queue Uniform Call Distribution UCDTimed Reminder Trunk Direct AppearancesVoice Guide Voice Mail Private PasswordUniform Numbering Plan UNP -Voice and Data Variable Timing ParametersWhisper Voice Mail TransferVoice Over IP H.323 VoIP Log CollectionCcis Feature List Ccis Features Descriptions Call Forwarding Intercept Ccis Centralized E911 Ccis Flexible Numbering of Stations Ccis Multiple Call Forwarding All Calls Ccis Station-to-Station Calling Ccis Isdn Feature List Isdn Feature Descriptions Event-Based Ccis SIG Feature Descriptions SIG Feature ListWireless Feature List Ccis Univerge Neax 2000 IPS Table of Features by Configuration TypeFeature Adjunct Type Integrated Type Analog PBX Interface Wired for WirelessWireless Feature Descriptions Group Call 2Way Calling This feature protects a call from being tapped Page System Input/Output I/O Interfaces Station Message Detail Recording Smdr2400 Extended Format IMS Format Smdr Terminal InterfaceSmdr w/AP00 ARP, IP, ICMP, UDP, TCP Combinations between Smdr and Smdr Output FormatCombinations available at the same time Pattern DCombinations for Local Office of Centralized Billing Combinations for Center Office of Centralized BillingSystem Capacity Data Transmission Sequence for Ethernet InterfaceMessage Center Interface MCI Hardware Required for SmdrDescription Qty Remarks Hardware Required for MCI VMSModem Type of Information FeatureFeature Property Management System PMSPMS Interface Hardware Required for PMS Description Qty RemarksRS PRT-4S CA-A OpenWorX Business Attendant System BAS Open Application InterfaceSystem Outline OpenWorX Attendant StatisticsBAS Call Control Functionality Brief Description of Call Control Function Brief Definition of QueuesBAS Speed Dials Pad BAS DirectoryDid for Company Lookup BAS Call Recording and Playback BAS Offline Mode Pseudo Night ModeBAS Authorization and Account Code Dialing BAS Overhead PagingBR Overhead Paging OpenWorX Business Receptionist BRBR Speed Dials Pad BR DirectoryBR Authorization and Account Code Dialing OpenWorX Communications PortalBR Attendant PC Minimum Hardware Requirements Communications Portal Benefits Communications Portal FunctionalityOpenWorX Dialer Dialer DatabaseDialer Benefits OpenWorX Message Reader MR OpenWorX Location Status Information LSIOpenWorX Short Text Messaging MR BenefitsSTM Benefits OpenWorX Incoming Call Assistant ICA ICA FunctionalityICA Benefits OpenWorX Group Call Forward Control Gcfc ICA Comparison of ICA and IPS FunctionalityICA ICA vs. Camp On Gcfc Functionality OpenWorX Personal Call Assistant PCAPersonal Directory PCA Limiting User ViewsPCA OpenWorX Desktop Desktop DirectoryPCA OpenWorX Inaset OpenWorX Name DisplayBusiness Receptionist Ccis Network Information OpenWorX Multiple Ccis Node ConfigurationOAI Application Software Development BAS Ccis Network InformationPage Automatic Call Distribution ACD with MIS Automatic Call Distribution ACDBasic ACD Call Waiting Indication ACD Basic ACD FeaturesDelay Announcement ACD Busy In/Busy Out ACDQueue Size Control-ACD CallCenterWorX ACD 3.0 for BusinessImmediate Overflow ACD Priority Queuing ACDCallCenterWorX ACD Features Automatic Call Distribution with MIS CallCenterWorX ACD 3.0 for Business Turnkey Packages CallCenterWorX MISBusiness Turnkey Packages Business Software Only PackagesCallCenterWorX MIS Bhca Business System CapacitiesItem ACD Capacities CallCenter WorX MIS 5GBPBX Requirements Remarks PBX RequirementsRelated Documents ACD TerminalsMaster Contact Center Solutions MasterContact Routing Q-Control Announcements Q-Announce Reports Q-ControlAgent Desktop Q-Desktop Multi-Media Q-Email, Q-Chat, Q-Fax Callbacks Q-CallbackInteractive Voice Response Q-IVR Outbound Dialing Q-OutdialQueWorX 4.0 Features QueWorX 4.0 Licensed ApplicationsAuto Attendant Estimated Time to Answer ETA Immediate Customer CallbackScheduled Callbacks Internet Initiated CallbacksGlobal Repeat Verification Screen PopSoft Phone Multilingual AnnouncementsProfessional Services for QueWorX Customized AnnouncementsCustomizable Reports Voice over IP VoIP VoIP SolutionsExtended Enterprise IP Solution VoIP SolutionsEquipment Name Function Typical IP Gateway, Branch and Adapter configurationsIP Station Peer-to-Peer Connections over Ccis Networking via IP Peer-to Peer Connections between IP Enabled DtermRemote Connections of IP Stations Connections to Legacy Stations and TrunksAutomatic Program Download for IP Enabled Dterm 8IPLA/24IPLA Options Per Location Service Conditions on System Registration Service Conditions on Legacy Service FeaturesService Conditions on Encryption in System Registration Service Conditions on VlanMD5 is an algorithm defined in RFC 1321 from the Ietf Local Connection Mode Remote Connection Mode Service Conditions on Remote ConnectionsExample 2 When Sta logs in Location #2 Location number in each operation mode for each IP stationOperation mode for each IP terminal Example 1 When Sta logs in Location #1Service Conditions on Automatic Program Download SPN-16VCTAA IP PAD Ccis Networking via IPRequired Equipment for IP Station SPN-32IPLAA IP PADCcis Networking via IP Peer-to-Peer Connections Basis Ccis Networking via IP Non Peer-to-Peer Connections Basis Point-to-Multipoint ConnectionIP Trunk Point-to-Multipoint Connection Payload Period Maximum Voice Channels per IP Trunk Service Conditions IP Ccis via IP Trunk cardsIP Trunk Card Specifications Required Equipment for IP Ccis via IP Trunk cardsConnection Features FeaturesService Conditions for H.323 Required Equipment for H.323 IP Trunk SpecificationsExample of FAX and Modem over IP connection FAX and Modem over IPSPN-32IPLA IP PAD-E SPN-8IPLA IP PAD-CSPN-8IPLA IP PAD-B SPN-8IPLA IP PAD-AOwn Required Equipment for FAX or Modem over IPOpposite Office 2000 IPS Opposite OfficeRequired bandwidth for FAX Connection Required bandwidth for Modem ConnectionConnection Conditions Required Bandwidth One-way Remote PIM over IP Network Conditions and PayloadRequirement Remarks Bandwidth Requirement With G7.23.1 With G729a 8k Without Compression 3k/6.3kCompression Advantages Required Hardware and Software Host Site Equipment Name RemarksRemote Site Equipment Name Remarks XNote List of Service Features OperationBandwidth requirements Planning and InstallationVendor Support for Open System Standards Voice MessagingNetwork Bandwidth Network ConsiderationBandwidth utilization Codec Filler Time MsecCodec Total Bandwidth per transmit stream Msec Device Registration Server DRS and Dhcp Quality of Service QoSPort Type Destination Default Port No Remarks For Dterm IPFor Voice Control/Voice Packet PBX TCP For Ccis Virtual IPTFor H.323 IP Trunk IPT CcisSystem Conditions/Limitations Peer-to-Peer IP LimitationsConditions Common Channel Inter-Office Signaling Ccis System Outline of a Ccis Connection Ccis and Isdn Digital and Analog Ccis Digital CcisAnalog Ccis Voice Compression Peer-to-Peer ConnectionsCommon Channel Inter-Office Signaling Ccis Ccis Networking via IP Non Peer-to-Peer Service Conditions on Non Peer-to-Peer ConnectionsCentralized Billing Local office/Tandem officeCenter office Common Channel Inter-Office Signaling Ccis Centralized E911 Ccis Look Ahead Routing Call Set Up TimesAlternate Routing Shared Trunk Facilities and Alternate RoutingCentralized System Maintenance and Administration Centralized Maintenance FacilityCentralized Management Center Centralized Call Accounting / Billing Centralized Call Accounting/Billing SystemsCentralized Voice Processing / Messaging Centralized Attendant ConsolesCcis Centralized Voice Mail YES Ccis Feature ChartCcis Feature Name Neax 2400 Required Uniform Numbering PlansCcis Feature Chart System Capacity for Ccis Networking via IP System CapacitySystem Capacity for Ccis with Digital Interface System Capacity for Ccis with Analog InterfaceRequired Equipment for Ccis Networking via IP Required EquipmentRequired Equipment for Digital Ccis Required Equipment for Analog Ccis24IPLA IP SpecificationsSpecifications Remarks PADCharacteristics Channel DTI SpecificationsPage Isdn Primary Rate Interface Integrated Services Data Network IsdnPRI Services & Features Isdn Feature ListCall-By-Call Service Selection Called Party Recognition Service Direct-In Termination DITCPN To Network-Present CPN To Terminating User-Display AT&T Did AddressingDid and DOD Addressing Isdn TerminalPage Subaddress-Present Megacom Access/WATSMegacom 800 Service/800 Wats Ultra Wats Multiquest /900 ServiceEvent Based Ccis Trunk Provisioning Service SelectionBusiness Feature List Business Feature ListIsdn Network Requirements for Layer One Supported Network Services Trunk provisioned onlyFor 24PRT Isdn PRI SpecificationsFor 24DTI For 30DTIBRT DMS Provisioning 4ESS NET Dedicated Access AT&T NTI MCI SprintDMS Selection 4ESS NET NET IPSAT&T NTI MCI Sprint Voice Features DMS 4ESS NETAT&T MCI Sprint Virtual Private Network DMS 4ESS NET AT&T MCI Sprint Selection DMS 4ESS NET IPS Switched DataDedicated Access NTI AT&T MCI Sprint Provisioning DMS 4ESS NET IPS Switched DataVirtual Private Network AT&T NTI DMS 4ESS NET Services and Features LEC CarriersCall by Call Service AT&T NTI Siemens Selection 5ESS Dedicated Access AT&T NTI SiemensNetwork Message Waiting Voice Features AT&T NTI SiemensAT&T NTI Siemens Facility ManagementVirtual Private Network AT&T NTI Siemens Call By Call Service SelectionEwsd Switched Data AT&T NTI Siemens 5ESSApplications Isdn Basic Rate Interface BRIONE SC03 Supports Four 2ILCA System RequirementsIsdn Terminal Required Equipment Isdn Equipment ListIsdn PRI Required Equipment Isdn BRI Required Equipment24DTI 24PRT DocumentationCapacity for ISDN-PRI System Capacity for ISDN-BRIPage Analog PBX Interface Wireless SystemUniverge Neax 2000 IPS Wireless Communication System WCS Wired for WirelessCcis Interface Wireless Roaming Multi-Site Roaming 931a Roaming over IP Trunk HLR Wireless DefinitionsConfiguration Application Integrated Type Wireless Short Text Message Notification OAIAdjunct Type Integrated Type FeaturesFeature Matrix by Configuration Type 2000 IPS Interface1 Interface2 Wired for WirelessFeature Descriptions Handover Wired forWireless Way CallingIndication AuthorizationPreset Dialing Out of ZoneDterm PS System DescriptionHeadsets Dterm PS III AccessoriesLithium-Ion Battery Battery ChargerZone Transceiver II ZT Wireless Specifications Zone Transceiver II SpecificationsIntegrated Adjunct Analog Adjunct Ccis Equipment Description QTY Remarks WCS Required EquipmentPN-4VCTI 4VCT PN-IPTB IPTWireless LAN Wireless LAN HandsetWireless LAN Documentation Terminal Console Hotel Feature ListHotel/Motel System PMSStation Message Detail Recording Smdr Application ProcessorHotel Console Hotel/Motel Front Desk TerminalExecuted Task Print Out Hotel PrinterAutomatic Wake-up Check Check In / Check OutDirect Data Entry Do Not Disturb ConsoleDo Not Disturb-Hotel/Motel Do Not Disturb-SystemHotel/Motel Attendant Console Hotel/Motel Front Desk Instrument Maid Status House PhoneVoice Message Waiting Individual Message RegistrationMessage Waiting Voice Message Waiting SystemProperty Management System PMS Room Cutoff Console Room CutoffRoom Status Single Digit DialingItems indicated are as follows Specifications PMS/SMDR Interface Hotel Printer Interface Hotel System CapacityDescription Capacity SN716 Deskcon Station EquipmentAIMWorX Call AccountingMulti-Site Centralized Operations AIMWorX databasesSelect Database Licensing Option Description Licensing Information you need before installing AIMWorXSQL Server licensing Oracle databaseConfigurations StandaloneCall Record and User Capacity Enterprise tier AIMWorX ManagerIntegrating AIMWorX modules Corporate tierAuth Code Manager Alarm Manager1 SPE Asset ManagerHospitality Links Bill ReconcilerCable Manager Custom SPE WriterWork Order Additional Reference MaterialTrouble Ticket Voice Mail SPEVoice Mail Integration Voice Messaging SystemsVoice Messaging Systems Description MCI Service Conditions System Architecture NEAXMail AD-120Level II Server Software License with Exchange Voice CardsClient Access Licenses CAL Third Party SoftwarePlatform Components PBX Integration Software Optional Software Feature PackagesMail Reader Text-to-Speech Third Party Fax Server Integration2GB Platform SpecificationsNEAXMail AD-64 40GB Sata 36GB Scsi Level I/Level II Platform SpecificationsLevel I/Level II Specifications Platform Level Level I Dell GX280 Level II Dell PE2800Optional ActiveFax Software UPS Uninterruptible Power SupplyAdditional Hardware Components Optional SoftwareUnified Messaging Hacker Prevention Features are as follows Voice Messaging Systems Voice Messaging Systems Available Languages Automated AttendantMailbox Manager AudiotextVoice Messaging Systems Maintenance Voice Messaging Systems ViewMail Visual MessagingViewCall Plus NEAXMail IM-16 LX Unified Messaging and Call ManagementFull Digital Integration Hospitality Feature Package Basic FeaturesEnjoy the Benefits of Integrated Messaging Additional Features Univerge Neax 2000 IPS Technical Manuals Niverge Neax 2000 IPS Features and SpecificationSystem Documentation Univerge Neax 2000 IPS Documentation List