CHAPTER 4 CIRCUIT CARD INFORMATION
List of Required Circuit Card
Lamp Indications
LAMP | COLOR |
| FUNCTION |
NAME |
| ||
|
|
| |
|
|
| |
RUN | Green | Flashes at 120 IPM when this card is normally operating. | |
|
|
| |
PCM | Red | Remains lit when detecting PCM signal loss. | |
|
|
| |
FRM | Red | Remains lit when detecting Frame Alignment signal loss. | |
|
|
| |
MFRM | Red | Remains lit when detecting | |
|
| time Slot 16. |
|
|
|
| |
RMT | Red | Remains lit when receiving the alarm from a distant office | |
|
| because Frame Alignment signal loss has been detected at the | |
|
| distant office. |
|
|
|
| |
MRMT | Red | Remains lit when receiving the alarm from a distant office | |
|
| because | |
|
| at the distant office. | |
|
|
| |
AIS | Red | Remains lit when indicating that the pattern of consecutive “1” is | |
|
| being received. The distant office transmits this signal for a loop- | |
|
| back test distant. |
|
|
|
|
|
BL | Red | B Channel status |
|
|
| ON | : More than10 channels are busy |
|
| OFF | : All channels are idle |
|
| Flash (60 IPM) | : Only one channel is busy |
|
| Flash (120 IPM) : 2 to 10 channels are busy | |
|
|
|
|
NEAX2000 IVS2 | Page 51 |