| Error Codes (continued) | |
|
|
|
Code | Explanation | Action Needed |
|
|
|
55 | Elevator tray 2 malfunctioned. | Open paper cassette #2. Check paper position, |
|
| and close paper cassette. If the problem persists, |
|
| call for service. |
|
|
|
56 | Elevator tray 3 malfunctioned. | Open paper cassette #3. Check paper position, |
|
| and close paper cassette. If the problem persists, |
|
| call for service. |
|
|
|
57 | Elevator tray 4 malfunctioned. | Open paper cassette #4. Check paper position, |
|
| and close paper cassette. If the problem persists, |
|
| call for service. |
|
|
|
58 | The ozone fan malfunctioned. | Turn the printer off and then on again. If the |
|
| problem persists, call for service. |
|
|
|
59 | The power supply fan malfunctioned. | Turn the printer off and then on again. If the |
|
| problem persists, call for service. |
|
|
|
80 | There is a problem with the sorter. | Turn the printer off and then on again. If the |
|
| problem persists, call for service. |
|
|
|
Preventive Maintenance Codes
Code | Explanation | Action Needed |
|
|
|
P0 | EP unit needs replacement. | Install a new EP unit*, or call for service. |
|
|
|
P2 | The toner collection bottle is full. | Replace with a new collection bottle. See |
|
| page |
|
|
|
Caution Codes
Code | Explanation | Action Needed |
|
|
|
C0 | The toner collection bottle is near full. The | Replace the toner collection bottle with a new |
| printer will shut down approximately 500 | one. See page |
| prints after this error is posted. |
|
|
|
|
C1 | The toner bottle is almost empty. | Replace the toner bottle with a new one. |
|
| See page |
|
|
|
C2 | The fuser web is almost used up. The printer | Replace with a new fuser unit* or call for service. |
| will shut down approximately 500 prints |
|
| after this error is posted. |
|
|
|
|
*These maintenance procedures are to be performed by Kodak authorized and fully trained persons only. These errors (for the EP unit and fuser unit) normally appear every 150,000 prints. At this time, an Image Quality Kit needs to be installed. This kit includes: a new EP unit, a fuser unit, a transfer/separator corona, and feed rollers. Customers with a Shared Maintenance Agreement will install the Image Quality Kit. Other customers should call Service immediately.