NEC MD213MC manual Ntaa SW, English-16

Page 18

Tag3

Auto Adjust

 

Automatically adjusts the Image Position and V.Size (H.Size) settings and Fine settings.

 

(Analog input only)

 

Press ÒSELECTÓ to activate Auto Adjustment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal Adjust

 

Determines when the auto adjustment is activated automatically.

 

 

 

(Analog input only)

 

The choices are ÒSIMPLEÓ and ÒFULLÓ. Press ÒLeftÓ or ÒRightÓ to select.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V.Size (H.Size), Fine, H/V Position

Contrast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIMPLE

 

O

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FULL

 

O

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O: Automatic Adjustment

X: No Automatic Adjustment

 

 

 

 

 

NOTE: Automatic Adjustment does not work at resolutions less than 800x600 resolution.

 

 

 

 

 

 

 

 

 

 

 

 

Auto Adjust Level

 

Determines the automatic adjustment level for Auto Adjust. The choices are ÒSIMPLEÓ,

 

(Analog input only)

 

ÒFULLÓ and ÒDETAILÓ. Press ÒLeftÓ or ÒRightÓ to select. Refer to the below table.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size, Fine, Position

Contrast

 

Black Level,

 

Time

 

 

 

 

 

 

 

 

 

Long cable capability**

 

 

 

 

 

 

SIMPLE

O

 

X

 

 

X

 

1 second

 

 

 

 

FULL

O

 

O

 

 

X

 

1.5 seconds

 

 

 

 

DETAIL*

O

 

O

 

 

O

 

5 seconds

 

 

 

 

O: Automatic Adjustment X: No Automatic Adjustment

 

 

 

 

 

* ÒDETAILÓ activates automatic long cable (skew, peaking) adjustment.

 

 

 

 

 

** Black level, RGB sharpness, RGB delay and RGB position are adjusted using ÒLong cable softwareÓ

 

 

 

which is included in the attached CD-ROM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A-NTAA SW

 

The Advanced No Touch Auto Adjust function is able to recognize new signals even when

 

(Analog input only)

 

neither the resolution nor the refresh rate has changed. If several PCs are connected to

 

 

 

the monitor, and each transmit very similar (or even the same) signals in terms of

 

 

 

resolution and refresh rates, the monitor recognizes that there is a new signal and

 

 

 

automatically optimizes the picture without the need for any action on the part of the user.

 

 

 

OFF: A-NTAA is disabled.

 

 

 

 

 

 

 

 

 

 

ON: If a change in signal is detected A-NTAA will adjust the monitor to the optimal settings

 

 

 

for the new signal. If no change in the signal is detected then A-NTAA does not activate.

 

 

 

The screen will be blank while the monitor optimizes the signal.

 

 

 

 

 

OPTION: Functions the same as ON, except that the screen does not go blank when the

 

 

 

monitor makes adjustments for changes in signal, allowing the monitor to display the new

 

 

 

signal faster. When using an external switching device to connect 2 or more PCs to the

 

 

 

monitor, using the ON or OPTION settings is suitable.

 

 

 

 

 

 

 

 

 

 

 

 

 

Tag4

H. Position*

 

Controls Horizontal Image Position within the display area of the LCD.

 

 

 

Press ÒLeftÓ or ÒRightÓ to adjust.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V. Position*

 

Controls Vertical Image Position within the display area of the LCD.

 

 

 

Press ÒLeftÓ or ÒRightÓ to adjust.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V.Size (H.Size)

 

Adjusts the horizontal size of the screen.

 

 

 

(Analog input only)

 

If the ÒAUTO Adjust functionÓ do not give you a satisfactory picture setting, a further

 

 

 

tuning can be performed using the ÒV.Size (H.Size)Ó function (dot clock). For this a MoirŽ

 

 

 

test pattern could be used. This function may alter the width of the picture. Use left/Right

 

 

 

Menu to center the image on the screen. If the V.Size (H.Size) is wrongly calibrated, the

 

 

 

result would look like the left drawing. The image should be homogeneous.

 

 

 

 

 

 

 

 

 

 

 

 

Fine

 

Improve focus, clarity and image stability by increasing or decreasing this setting.

 

(Analog input only)

 

If the ÒAuto Adjust functionÓ and the ÒV.Size (H.Size)Ó function do not give you a

 

 

 

satisfactory picture setting, a fine tuning can be performed using the ÒFineÓ function.

 

 

 

For this a MoirŽ test pattern could be used. If the Fine value is wrongly calibrated, the

 

 

 

result would look like the left drawing. The image should be homogeneous.

 

 

 

 

 

 

 

 

 

 

 

 

H. Resolution*

 

Adjusts the horizontal size by increasing or decreasing the setting.

 

 

 

Press ÒRightÓ button to expand the width of the image on the screen.

 

 

 

Press ÒLeftÓ button to narrow the width of the image on the screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

V. Resolution*

 

Adjusts the vertical size by increasing or decreasing the setting.

 

 

 

 

 

Press ÒRightÓ button to expand the height of the image on the screen.

 

 

 

Press ÒLeftÓ button to narrow the height of the image on the screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

Expansion*

 

Sets the zoom method.

 

 

 

 

 

 

 

 

 

 

FULL: The image is expanded to 1200 x 1600 (portrait mode) or 1600 x 1200 (landscape

 

 

 

mode), regardless of the resolution.

 

 

 

 

 

 

 

 

 

ASPECT: The image is expanded without changing the aspect ratio.

 

 

 

OFF: The image is not expanded.

 

 

 

 

 

 

 

 

 

CUSTOM: When CUSTOM is selected as the Expansion mode, it becomes possible to

 

 

 

adjust the H. ZOOM., V. ZOOM, and ZOOM POS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*When digital QXGA (1536 x 2048 or 2048 x 1536) of the medical monochrome signal is connected, this function does not operate (MD213MC/MD213MG only).

English-16

Image 18
Contents MD212MC MD213MC MD213MG Symbol Information IndexIntended Use Power Cord Important InformationSafety Precaution North America CustomersRegistration Information Safety Precautions and Maintenance Recommended useEnglish-3 Ergonomics Cleaning the LCD PanelCleaning the Cabinet English-4Contents Quick Start English-6Monitor Figure E.1. Turn on the computer English-7Tilt Raise and Lower Monitor ScreenScreen Rotation SwivelMount Flexible arm Flexible Arm InstallationRemove Monitor Stand English-9Controls English-10Image Controls Auto Adjust Analog input onlyLuminance/Contrast Controls English-11Color Control Systems Only for MD212MC/MD213MC ToolsEnglish-12 Menu Tools English-13Information OSD WarningEnglish-14 Advanced OSD How to use the advanced menuHow to exit the advanced menu English-15Ntaa SW English-16Zoom Zoom POSEnglish-17 OFF Mode UniformityEnglish-18 DDC/CI Boot LogoLock OUT English-19English-20 Calibration Self CalibrationEnglish-21 Copy Calibration ÒexitóEnglish-22 Gamma Adjust English-23Dicom Measurement English-24Specifications MD212MC Monitor Specifications MD212MC MonitorEnglish-25 Specifications MD213MC Monitor Specifications MD213MC MonitorEnglish-26 Specifications MD213MG Monitor Specifications MD213MG MonitorEnglish-27 Features English-28Troubleshooting Energy Saving Manufacturer’s Recycling and Energy InformationDisposing of your old NEC product Weee Mark European Directive 2002/96/EC

MD213MC specifications

The NEC MD213MC is a robust medical-grade display designed to meet the rigorous demands of healthcare environments. With a resolution of 2 megapixels, this monitor offers exceptional clarity and detail, essential for effective diagnosis and patient care. It features an active matrix TFT LCD panel that ensures superb image quality and consistency across various lighting conditions.

One of the standout features of the MD213MC is its high brightness level, which significantly enhances visibility and allows for clear viewing of images even in brightly lit examination rooms. The monitor supports a wide color gamut, ensuring that colors are reproduced accurately and that the display can handle diverse imaging applications.

The display is equipped with advanced medical imaging technologies, including a DICOM Part 14 compliance for grayscale images. This feature is crucial as it ensures that medical images, such as X-rays and MRIs, are displayed with the necessary contrast and brightness, assisting healthcare professionals in making informed decisions based on precise image analysis.

Another significant characteristic of the MD213MC is its ergonomic design. It includes a lightweight and slim profile, which makes it easy to mount in various clinical settings. The monitor can be adjusted for height, tilt, and swivel, enhancing the comfort of users during long hours of operation.

The MD213MC also incorporates an automated calibration feature that ensures consistent image quality over time. This is particularly important in medical settings, where even minor discrepancies in image display can lead to varying diagnostics.

Connectivity is another strong aspect of the NEC MD213MC. The monitor offers multiple input options, including DisplayPort and DVI, making it compatible with a wide range of medical imaging equipment. Additionally, the monitor includes USB ports for easy connection to peripheral devices, enhancing its versatility.

In terms of compliance, the NEC MD213MC adheres to stringent medical safety and performance standards, ensuring that it functions reliably in critical environments. Its combination of high-resolution imaging, ergonomic design, and advanced display technologies makes it an ideal choice for hospitals and clinics looking to enhance their imaging capabilities for improved patient outcomes. Overall, the MD213MC represents a significant advancement in medical display technology, providing healthcare professionals with the tools necessary for effective diagnosis and treatment.