NEC MD213MC manual Zoom POS, English-17

Page 19

 

H.ZOOM

The image is expanded from 1 to 3 times in the horizontal (H. EXPANSION) direction by

 

(Available in Custom

0.01 increments.

 

Expansion mode only)

 

 

 

 

 

V.ZOOM

The image is expanded from 1 to 3 times in the vertical (V. EXPANSION) direction by

 

(Available in Custom

0.01 increments.

 

Expansion mode only)

 

 

 

 

 

ZOOM POS.

Sets the point from which the screen will be expanded when either H.ZOOM or V.ZOOM is

 

(Available in Custom

selected as the expansion method. Options are CENTER and LEFT TOP.

 

Expansion mode only)

CENTER: H.ZOOM expands the image from the centre outward to the sides of the screen.

 

 

V.ZOOM expands the image from the centre towards the top and bottom of the screen.

 

 

LEFT TOP: Indicates the set point for image expansion (TOP in V. Zoom, LEFT in

 

 

H.ZOOM). If the resolution does not fill out the screen, when expanding, the image will not

 

 

expand past the TOP or the LEFT of the screen. The image can be expanded past the

 

 

right and bottom edges of the screen.

 

 

 

Tag5

Gamma Selection

Allows you to manually select (Gamma function*) the brightness level of grayscale.

 

 

There are five selections:

 

 

NO CORRECTION, DICOM, LOG LINEAR, CUSTOM and PROGRAMMABLE.

 

 

NO CORRECTION: No correction possible.

 

 

DICOM: DICOM GSDF (Grayscale Standard Display Function) is possible. The DICOM

 

 

LUT is calculated based on the factory calibration data for each individual display.

 

 

If you use an analog input, please execute Auto Contrast and Auto Black Level in Tag1.

 

 

LOG LINEAR: Luminance changes log rhythmically in response to a linear change of

 

 

gradation.

 

 

CUSTOM: This is displayed as numerical value which you selected. The gamma value is

 

 

selected from a range of 1.0 to 3.0 by 0.1 intervals. When the COLOR CONTROL is

 

 

sRGB, the value is fixed at 2.2 and NOT ADJUSTABLE. ÒPRIORITYÓ can be adjusted

 

 

when CUSTOM is selected.

 

 

PRIORITY (only for MD212MC/MD213MC): Sets gamma characteristics for optimum

 

 

viewing of contrast or color.

 

 

GRAYSCALE: Optimizes gamma for contrast.

 

 

COLOR: Optimizes gamma for color images.

 

 

PROGRAMMABLE: The brightness of grayscale can be changed by using the

 

 

GammaCompMD Software.

 

 

*Gamma - The way brightness is distributed across the intensity spectrum by a monitor,

 

 

Gamma is relationship between the input voltage and resulting intensity of the output.

 

 

A perfect linear device would have a gamma of 1.0. A gamma correction function is used

 

 

to alter the luminance (light intensity) of a display such that its brightness (the human

 

 

perceived value) appears correct.

 

 

 

Tag6

Color Control (Only for

Color Control Systems: Nine preset color settings.

 

MD212MC/MD213MC)

For preset settings 1, 2, 3 and 5, the following levels can be adjusted:

 

 

TEMPERATURE: Adjust the white temperature by increasing or decreasing this setting.

 

 

A lower color temperature will make the screen reddish and a higher color temperature

 

 

will make the screen bluish.

 

 

WHITE (White Balance): If TEMPERATURE needs further adjustment; the individual

 

 

R/ G/ B/ levels of the white point can be adjusted. To adjust the R/G/B levels, CUSTOM

 

 

must be showing as the TEMPERATURE selection.

 

 

HUE: Adjusts the hue of each color*1. The change in color will appear on screen and

 

 

the menu color bars will show the amount of adjustment.

 

 

SATURATION: Adjusts the color depth of each color*1. Press the ÒRIGHTÓ button and

 

 

the color vividness increases.

 

 

OFFSET: Adjusts the color brightness of each color*1. Press ÒRIGHTÓ button and the

 

 

color Brightness increases.

 

 

*1: RED, YELLOW, GREEN, CYAN, BLUE and MAGENTA.

 

 

NATIVE, sRGB: Original color presented by the LCD panel that is unadjustable.

 

 

PROGRAMMABLE: The color tone that was set up with the special application software is

 

 

reflected.

 

 

CLEAR BASE: Color temperature setting for Clear Base x-ray film simulation.

 

 

BLUE BASE: Color temperature setting for Blue Base x-ray film simulation.

 

 

 

English

English-17

Image 19
Contents MD212MC MD213MC MD213MG Index Symbol InformationNorth America Customers Power Cord Important InformationSafety Precaution Intended UseRegistration Information Recommended use Safety Precautions and MaintenanceEnglish-3 English-4 Cleaning the LCD PanelCleaning the Cabinet ErgonomicsContents English-6 Quick StartEnglish-7 Monitor Figure E.1. Turn on the computerSwivel Raise and Lower Monitor ScreenScreen Rotation TiltEnglish-9 Flexible Arm InstallationRemove Monitor Stand Mount Flexible armEnglish-10 ControlsEnglish-11 Auto Adjust Analog input onlyLuminance/Contrast Controls Image ControlsTools Color Control Systems Only for MD212MC/MD213MCEnglish-12 English-13 Menu ToolsOSD Warning InformationEnglish-14 English-15 How to use the advanced menuHow to exit the advanced menu Advanced OSDEnglish-16 Ntaa SWZoom POS ZoomEnglish-17 Uniformity OFF ModeEnglish-18 English-19 Boot LogoLock OUT DDC/CIEnglish-20 Self Calibration CalibrationEnglish-21 Òexitó Copy CalibrationEnglish-22 English-23 Gamma AdjustEnglish-24 Dicom MeasurementMonitor Specifications MD212MC Monitor Specifications MD212MCEnglish-25 Monitor Specifications MD213MC Monitor Specifications MD213MCEnglish-26 Monitor Specifications MD213MG Monitor Specifications MD213MGEnglish-27 English-28 FeaturesTroubleshooting Weee Mark European Directive 2002/96/EC Manufacturer’s Recycling and Energy InformationDisposing of your old NEC product Energy Saving

MD213MC specifications

The NEC MD213MC is a robust medical-grade display designed to meet the rigorous demands of healthcare environments. With a resolution of 2 megapixels, this monitor offers exceptional clarity and detail, essential for effective diagnosis and patient care. It features an active matrix TFT LCD panel that ensures superb image quality and consistency across various lighting conditions.

One of the standout features of the MD213MC is its high brightness level, which significantly enhances visibility and allows for clear viewing of images even in brightly lit examination rooms. The monitor supports a wide color gamut, ensuring that colors are reproduced accurately and that the display can handle diverse imaging applications.

The display is equipped with advanced medical imaging technologies, including a DICOM Part 14 compliance for grayscale images. This feature is crucial as it ensures that medical images, such as X-rays and MRIs, are displayed with the necessary contrast and brightness, assisting healthcare professionals in making informed decisions based on precise image analysis.

Another significant characteristic of the MD213MC is its ergonomic design. It includes a lightweight and slim profile, which makes it easy to mount in various clinical settings. The monitor can be adjusted for height, tilt, and swivel, enhancing the comfort of users during long hours of operation.

The MD213MC also incorporates an automated calibration feature that ensures consistent image quality over time. This is particularly important in medical settings, where even minor discrepancies in image display can lead to varying diagnostics.

Connectivity is another strong aspect of the NEC MD213MC. The monitor offers multiple input options, including DisplayPort and DVI, making it compatible with a wide range of medical imaging equipment. Additionally, the monitor includes USB ports for easy connection to peripheral devices, enhancing its versatility.

In terms of compliance, the NEC MD213MC adheres to stringent medical safety and performance standards, ensuring that it functions reliably in critical environments. Its combination of high-resolution imaging, ergonomic design, and advanced display technologies makes it an ideal choice for hospitals and clinics looking to enhance their imaging capabilities for improved patient outcomes. Overall, the MD213MC represents a significant advancement in medical display technology, providing healthcare professionals with the tools necessary for effective diagnosis and treatment.