4078-00X
| FRU / Function | Action |
|
|
|
5 | Maintenance | Intermittent nozzle failures can be caused by worn |
| Station | parts in the maintenance station. Perform the |
|
| “Maintenance Station Service Check” on page |
|
| then return to this check. |
|
|
|
6 | Paper Feed | Ink smudging and smearing can be caused by |
|
| paper problems or problems in the paper feed |
|
| area. |
|
| Check the following: |
|
| • Correct type of paper is being used. Also check |
|
| the paper for curl or wrinkles. |
|
| • Feed rollers for wear, dirt, or looseness. |
|
| • Gears for wear or binds. |
|
| • Paper path for obstructions. |
|
|
|
7 | Carrier Transport | Blurred print and voids can be caused by problems |
|
| in the carrier transport area. Check the following: |
|
| • Carrier transport belt for wear. |
|
| • Carrier guide rod for wear or dirt. |
|
| • Carrier to carrier frame engagement should be |
|
| lubricated with grease P/N 1329301. Do not |
|
| lubricate the carrier guide rod. |
|
| • Idler pulley parts for wear, damage, or |
|
| looseness. |
|
|
|
8 | Alignment | Uneven vertical lines can be adjusted by |
|
| performing the bidirectional alignment. The user is |
|
| directed, through the Printer Control program, to |
|
| perform the bidirectional printing alignment, when |
|
| replacing a print cartridge. |
|
|
|