4036-304
Scan module does not move to lock position
Cause | Relevant | Check | Action | |
Unit | ||||
|
|
| ||
|
|
|
| |
Home | CCD board | Tester check | Replace the | |
position |
|
| CCD PCBA. | |
sensor board |
|
|
| |
failure |
|
|
| |
|
|
|
| |
None | Visual check | Connect the | ||
control PCBA |
|
| connector. | |
connection |
|
|
| |
failure |
|
|
| |
|
|
|
| |
Motor failure | Carrier motor | Visual check | Replace the | |
|
|
| carrier motor. | |
|
|
|
| |
Power supply- | None | Visual check | Connect the | |
main control |
|
| connector. | |
board |
|
|
| |
connection |
|
|
| |
failure |
|
|
| |
|
|
|
| |
Power supply | Power supply | Tester check | Replace the | |
fails. |
| (+24V, GND) | power supply. | |
|
|
|
|