If the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: PI401B” or “Contains FCC ID: PI401B.” Any similar wording that expresses the same meaning may be used.
13. Environmental
13.1Operating temperatures
Parameter | Min | Typ | Max |
Operating temp (standard product) | 25 | +85 | |
|
|
|
|
13.2Storage temperature
Parameter | Min | Max | Unit |
|
|
|
|
Storage temp | +125 | °C | |
|
|
|
|
Unit
°C
13.3Reliability
Parameter | Test | Comment |
|
|
|
Thermal Shock | 200 cycles | 1 cycle/hour |
|
|
|
Vibration | Continuous operation at 60 Hz, | 15g max sine wave, 12 hours |
| 2mm stroke |
|
|
|
|
Shock | 50G 11ms Half Sine Wave | 6 axis x 3 cycles each axis |
|
|
|
Moisture Resistance |
|
|
|
|
|
High Temp Storage | 85ºC, 360 hours |
|
|
|
|
Low Temp Storage |
| |
|
|
|
High Temp/Humidity | 60ºC, 90%RH, 360 hours |
|
Operation |
|
|
|
|
|
Thermal shock | 200 cycles with continuous | |
|
| operation |
|
|
|
Electro Static Discharge | EN55024:1998 & |
|
|
|
|
Drop Test | 75cm to concrete, 3 axis x 2 |
|
| cycles per corner |
|
|
|
|