Emerson 400A manual Index

Page 20

A

accessories, 5–2, 5–5 auxiliary circuits, 1–2

B

battery, 4–2, 5–1 buttons, push, 3–1

bypass time delay, 1–5, 2–1, 3–1

C

cable

lugs, preparation, 1–1 catalog number, cover cleaning, 3–1

connections

engine control contact, 1–2 line, 1–1

contacts auxiliary, 1–2 engine control, 1–2 main, 1–3, 3–1

source availability signal, 5–2

control features, 5–1 load disconnect, 5–4 motor load transfer, 5–4 plant exerciser, 5–1, 5–2, 5–3

controller, 4–1, 4–2 codes, cover cover removal, 4–2 disconnecting, 3–1

time delay potentiometers, 4–2

D

DIP Switches, 4–1, 4–2, 5–1, 5–2, 5–4

E

electrical operation, 1–5 engine exerciser, 5–1, 5–2, 5–3 engine starting contacts, 1–2

F

features, see control features

frequency, pickup and dropout settings, 4–1

functional test, 1–3, 1–4, 1–5

INDEX

G

ground, controller, 1–1

H

handle, maintenance, 1–3 warning, 1–3

harness, 1–2 disconnect plugs, 3–1

HELP 800–800–2726 (ASCO) customercare@asco.com

I

inphase monitor, 5–4 inspection, 3–1 installation, 1–1

L

labels,

engine starting contacts, 1–2 inputs / outputs, 1–2 rating, cover

lights, 1–4, 5–1

load disconnect feature, 5–4 lubrication, 3–1

M

maintenance, preventive, 3–1

manual load transfer, 3–2 warning, 3–2

manual operation, 1–3 illustration of, warning, 1–3

motor load transfer feature, 5–4

N

nameplate, cover

O

operation electrical, 1–5 manual, 1–3

illustration of, 1–3 warning, 1–3

sequence of, 2–1

optional accessories programmable engine exerciser

&source availability signal contacts, 5–2, 5–3

serial communication module, 5–5 strip heater, 5–5

P

parts, 3–1 problem, 3–2

programmable engine exerciser, 5–2, 5–3

R

rating label, cover

remote control features, 5–4 bypass transfer time delay, 5–4 inhibit transfer to emergency, 5–4 remote test, 5–4

remote transfer to emergency, 5–4 replacement parts, 3–1

S

service, call 800–800–2726 (ASCO) set engine exerciser, 5–1, 5–2, 5–3

settings changing, 4–1 factory, 4–1 frequency, 4–1 phase, 4–1 time delay, 4–1 voltage, 4–1

source accepted lights, 1–4, 1–5

T

terminal block, 1–2

test, functional, 1–3, 1–4, 1–5

time delay adjustment, 4–1 gen–set cooldown, 4–1 how to change, 4–2

override momentary outages, 4–1 settings, 4–1

transfer to emergency, 4–1 transfer to normal, 4–1

timer (plant exerciser), how to set, 5–1, 5–2, 5–3

transfer switch position lights, 1–4, 1–5

transfer test, 1–5, 3–1 trouble–shooting, 3–2

V

voltage, phase, 4–1

voltage, pickup and dropout settings, 4–1

Printed in U.S.A.

Copyright --- ASCO Power Technologies, L.P. 2011

 

Image 20
Contents Operator’s Manual Rating LabelPage Nameplate and Catalog Number Identification 300 400Page Installation Engine Starting Contacts HarnessesAuxiliary Circuits Controller GroundInstallation Functional Test Manual Operation TestInstallation Voltage ChecksElectrical Operation Retransfer to Normal Sequence of OperationTransfer To Emergency Disconnecting the Controller Testing & ServicePreventive Maintenance Testing & Service TROUBLE-SHOOTINGTrouble-Shooting the Motor Load Transfer Feature refer to Manual Load TransferAdjustments Time Delay AdjustmentSensor Adjustments Time Delay SettingsAdjustments How to Change a SettingSwitches SW3 actuator On each DIP switch Off onControl Features Engine Exercisers DIP Switch SettingsHow to Set Built-In Timer BUILT-IN Engine ExerciserControl Features Programmable Engine Exerciser ModuleDaylight Savings Time Adjust Display Fast / Slow Adjust DisplayFill in your settings for future reference Run Time DisplayLoad Disconnect Feature Remote Control FeaturesInphase Monitor For Motor Load Transfer Control Features Optional Strip Heater Accessory Strip Heater AccessoryAvailable Kits ControlsIndex