Additional Process
Adjustment Factors for Use with
Process
Step | R | G | B |
|
|
|
|
Yellow | 0.00 | 0.00 | 0.00 |
|
|
|
|
0.00 | 0.00 | +0.07 | |
|
|
|
|
HD | +0.04 | 0.00 | +0.07 |
|
|
|
|
LD | 0.00 | 0.00 | 0.00 |
|
|
|
|
0.00 | 0.00 | 0.00 | |
|
|
|
|
4.Process a control strip and measure the Yellow,
5.Calculate the variations from aim by subtracting the aim densities from your
the variations on your control chart. Plot variations that are higher than the corresponding aim values (+ values) above the aim line. Plot variations that are lower than the aim values (– values) below the aim line.
If any of the variations from aim plots beyond the action or control limits, process another control strip. If the second control strip confirms the results of the first strip, determine the cause of the problem. Using the “Visual Process Control Guide” on page 8 provides a good starting place. If the problem is not readily correctable, contact Kodak Service and Support at (866)
USING THE “VISUAL PROCESS CONTROL GUIDE” AND KODAK CONTROL STRIPS TO TROUBLESHOOT PROCESS
If your Process
First check for operational errors:
•Make sure the
•Calibrate the densitometer.
•
•Verify the problem by processing a second control strip.
•Determine if any recent processor maintenance could have caused a problem.
•Verify that tank and replenisher solutions were mixed correctly.
•Use an accurate thermometer to verify that the developer temperature and other solution temperatures are correct.
Match your plots to the “Visual Process Control Guide” to identify the problem:
•Match your control plots to the examples given on the “Visual Process Control Guide.” Compare only one
plot parameter at a time
•Write down the problems indicated by each parameter for the plots that are out of control. Consider that you may have more than one problem occurring at the same time.
•Consider each potential cause of the
When you have determined the most likely cause(s) of the
Corrective Action and Prescriptions
D-maxb – Yb:
This parameter monitors the performance of the bleach solution for retained silver. A bleach solution that is underreplenished or diluted will not efficiently bleach the film, leaving retained silver in
1.Immerse the processed control strip in the bleach tank, and soak it for 7 minutes.
2.Remove the strip, rinse it thoroughly with water for 3 minutes, and dry it.
3.
If the test confirms a bleaching problem, replace the bleach tank solution with fresh solution made from the KODAK Negative Film FC Tank Bleach, as described on page 3. Also check the output of the bleach replenisher pump and calibrate. Be sure that the bleach replenishment rate is set correctly.
Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • | 5 |