DDC Instructions
107T5 | 23X |
Go to cover page
Re-programming EEPROM (Software DDC)
Step 1: After initialize alignment box, connecting all cables and box as shown in Fig. 10
PC
Rear view of the monitor
Fig. 10
4.Click icon (Read EDID function) to read DDC EDID data from monitor. The EDID codes will display on screen as shown in Fig. 13.
Fig. 13
videocard | printerport(LTP1) |
To | To |
DC Power
8~12 V
~
Video cable
To
Monitor
Printer
Port
To PC
Step 3: Modify DDC data (verify EDID version, week, year)
1.Click (new function) icon from the tool bar, bring up Step 1 of 9 as shown in Fig. 14 .
EDID301 DDC application provides the function selection and text change (select & fill out) from Step 1 to Step 9.
Step 2: Read DDC data from monitor
Fig. 11
2.Select the DDC2B as the communication channel.
Select "Enable" & fill out "F0" for Mapped EDID page address as shown in Fig. 12.
Fig. 14
Step 4: Modify DDC data (Monitor Serial No.)
1.Click Next till the Step 7 of 9 window appears as shown in Fig. 15.
2.Fill out the new Serial No. (for example, TY 503960, TY 123456).
3.Click Next till the last step window appears, then click Finish to exit the Step window.
Fig. 15
Fig. 12
3.Click OK button to confirm your selection.