8 Technical data

Input Maximum capacity 1440VA

Voltage

100-120V* +/-25% at line input

Current 12A

Frequency

50 or 60Hz* +/-10% (auto sensing)

Output Capacity 1000VA

Voltage (on battery) Simulated sine wave at 100V/115V +/-5%

Frequency (on battery) 50 or 60Hz* +/-1Hz

Auto Voltage Regulation AVR automati- cally increases output voltage

(AVR function)

15% above input voltage if -9% to -25% of nominal.

AVR decrease output voltage 13% below input voltage

If +/-9% to +25% of nominal

Transfer time

2/4 milliseconds, including detection time

Protection and filtering

Spike protection 5100 joules, 2ms

Overload protection UPS automatically shuts down if overload exceeds 120% of nominal at 30 seconds and 130% at 3 seconds

Unit input

Fuse or circuit breaker for overload and short circuit protection

Short circuit

UPS output cut off immediately or input fuse protection

BatteryType

Sealed, maintenance-free lead acid

Recharge time

6 hours typically (to 90% of full capacity)

Protection

Automatic self test and discharge protection

Quantity of batteries

1

DC voltage 12V (DC)

Dimension: Main unit

Net weight 22.7lbs (10.3Kg)

Dimensions WxDxH 16.93” x 12.7” x 3.74” (mm) (430 x 323 x 95)

16

Image 16
Contents Uninterruptible Power System UPS Page Table of contents Your UPS Congratulations on your purchase and welcome to PhilipsElectronics and computer system Product highlightsWhat’s in the box What you’ll also needflashing light indicates the UPS is in battery back-up mode UPS overview Front panelLCD message panel display Digital clock Displays present timeConnect your UPS Getting StartedConnect your UPS to a phone/ fax/modem Connect your UPS to a TV/VCR/ DVDR/cable box Check the power requirement of your equipment Using your UPSTo connect coaxial cable protection Confirm all equipment connected to TipUsing more of your UPS Back-up alarmLow battery alarm Auto restartWarranty and Service Limited Lifetime WarrantyDigital clock StorageCalifornia Proposition 65 WARN- ING All Products Conditions and LimitationsThis connected equipment warranty is null and void if Warranty Claim Procedure This warranty does not cover damage due toExclusions Technical data Noise level 40dBA 1 meter from surface UL-listed rating What should I do if the UPS back-up time is too short?Page