2.3 UPS overview

1

2

3

4

5

6

 

7

 

 

 

 

Front panel

1Power switch:Turns power to the UPS on or off. May be used as the master ON/OFF switch for all equipment connected to the battery back-up out- lets by leaving the power buttons for the connected equipment ON.Also indicates the status of the UPS:

a steady light indicates the UPS is in- line mode and using AC current

a flashing light indicates the UPS is in battery back-up mode

2Time set control (minutes): Use this button to set the time in minutes.

3Liquid crystal display (LCD) message panel: Displays UPS status information and time.

4Surge protection LED indicator:A steady light signals surge protection is normal.

5Ground LED indicator:A steady light signals grounding is normal.

6EMI/RFI LED indicator:A steady light signals noise filtration is functioning properly.

7Time set control (hours): Use this but- ton to set the time in hours.

1

2

 

5

3

6

4

LCD message panel display

1Digital clock: Displays present time.

2AVR (Automatic Voltage Regulation) indicator: Illuminated “AVR Activate” signals the AVR is actively functioning.

3Battery charge level: Signals the bat- tery charging level in AC mode.

4Battery run time: Signals battery status in back-up mode.

5Input voltage: Measures the input voltage.

6Battery load level: Signals the total output load of the UPS.

1

2

3

4

5

6

7

8

9

Back panel

1Network line protection

2Telephone line protection with splitter (1 in/2 out)

3USB port for software/computer interface

4Surge protected outlets, stage 1 (up to 40dB)

5Surge protection outlets, stage 2 (up to 58dB)

6UPS battery back-up outlets, stage 3 (up to 65dB)

7Circuit breaker

8 Power cord input

9Four sets of coaxial line protection- with gold connectors

6

Image 6
Contents Uninterruptible Power System UPS Page Table of contents Your UPS Congratulations on your purchase and welcome to PhilipsWhat’s in the box Electronics and computer systemProduct highlights What you’ll also needLCD message panel display flashing light indicates the UPS is in battery back-up modeUPS overview Front panel Digital clock Displays present timeGetting Started Connect your UPSConnect your UPS to a phone/ fax/modem Connect your UPS to a TV/VCR/ DVDR/cable box Using your UPS Check the power requirement of your equipmentTo connect coaxial cable protection Confirm all equipment connected to TipLow battery alarm Using more of your UPSBack-up alarm Auto restartDigital clock Warranty and ServiceLimited Lifetime Warranty StorageCalifornia Proposition 65 WARN- ING All Products Conditions and LimitationsThis connected equipment warranty is null and void if This warranty does not cover damage due to Warranty Claim ProcedureExclusions Technical data Noise level 40dBA 1 meter from surface UL-listed rating What should I do if the UPS back-up time is too short?Page