RECEIVE MODULE FOR SERVSWITCH™ MULTI HUB

RECEIVE MODULE FOR SERVSWITCH™ MULTI HUB

NOTE

If it will be easier for you to configure the Receive Module while you’re looking at cables you’ve already installed, feel free to attach your expansion cables to the Module (refer to step 4) before you do step 3.

3. Next you will need to configure the DIP switches on your Receive Module. The Module has sixteen dual-RJ-45

Receive ports on it, numbered 1 through 16 from left to right, as shown in Figure 3 on the next page. Each

Up to 125 ft. (38.1 m)

ON

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

1

2

1

2

1

2

From over 125 ft. (38.1 m)

to 225 ft. (68.6 m)

ON

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

1

2

1

2

1

2

From over 225 ft. (68.6 m)

to 250 ft. (76.2 m)

ON

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

1

2

1

2

1

2

port has three two-position DIP switches that you need to set for the length of the Category 5 cable that will be

attached to the port. The locations of these DIP switches are shown in Figure 1, and their possible settings are

shown in Figure 2 on the next page. For any given Receive port, leave all of the switch positions set to OFF if

the cable you’ll be attaching to that port isn’t more than 125 ft. (38.1 m) long. If the cable is longer than

125 ft. (38.1 m) but not more than 225 ft. (68.6 m), move the left-hand position in each switch to ON. If the

cable is longer than 225 ft. (68.6 m), up to the Switch’s maximum supported CAT5 expansion-cable length of

250 ft. (76.2 m), move all of the switch positions to ON.

PORT 1

PORT 2

DIP Switch Area

DIP Switch Area

PORT 3

PORT 4

DIP Switch Area

DIP Switch Area

PORT 5

PORT 6

DIP Switch Area

DIP Switch Area

PORT 7

PORT 8

DIP Switch Area

DIP Switch Area

PORT 9

PORT 10

DIP Switch Area

DIP Switch Area

PORT 11

PORT 12

DIP Switch Area

DIP Switch Area

PORT 13

PORT 14

DIP Switch Area

DIP Switch Area

PORT 15

PORT 16

DIP Switch Area

DIP Switch Area

Figure 1. The DIP-switch areas on the Receive Module’s circuit board.

Figure 2. The Receive Module’s possible DIP-switch settings.

Video

Keyboard/

Mouse

Figure 3. The port layout of the Receive Module.

4.Remove the blanking plate on the Hub’s rear panel that covers the slot you want to install your Receive Module in. Gently slide your Module into the Hub’s chassis and tighten the retaining screws.

5.Lastly, referring to the layout you should have planned in step 1, run Category 5 cables between the ports on the Receive Module and the ports on the CAT5 Transmit Cards in the other ServSwitch Multi units in your system. For each Module-port/Card-port pair that you want to interconnect, one cable should connect the Module port’s video connector (the upper of its two RJ-45s) with the Card port’s video connector (the lowest of its three RJ-45s); a second cable should connect the Module port’s keyboard/mouse connector (the lower of its two RJ-45s) with the Card port’s keyboard/mouse connector (the middle of its three RJ-45s). Don’t make any connections to the Card port’s multimedia (serial/audio) connector (the uppermost of its three RJ-45s); the Hub doesn’t carry multimedia signals.

The Receive Module should now be ready for continuous operation, as soon as you update the configuration of the rest of your ServSwitch Multi system. Refer to your ServSwitch Multi system’s manual for information about operating the ServSwitch Multi Hub and the rest of your ServSwitch Multi system.