Installation
Setting the Link Interface Type
(Universal WAN only)
The Universal WAN Interface must be configured to match the service to which it will be connected.
WARNING: ensure that the connector cable used with the Universal interface module has the correct pinouts for the operational mode selected for the interface (V.11/X.21, V.35, RS232/V.24, or RS530/RS422). Using the incorrect cable connector for the operational mode selected may cause permanent damage to the interface module. Please see Appendix D for pinout assignments.
7Set Link Interface Type: Location: Main
ÄConfiguration
ÄWAN Set Up
ÄLink Set Up
ÄLink Interface Type
Select the Service type to which this router will be connected.
Note: If the module is being changed from one type of service to another, you must first select “none” before a new selection may be chosen. Also the link must be toggled through a disable/enable cycle before the change is brought into effect.
11