z10 BC

The IBM System z10 Business Class (z10 BC) delivers innovative technologies for small and medium enter- prises that give you a whole new world of capabilities to run modern applications. Ideally suited in a Dynamic Infratructure, this competitively priced server delivers unparalleled qualities of service to help manage growth and reduce cost and risk in your business.

The z10 BC further extends the leadership of System z by delivering expanded granularity and optimized scalability for growth, enriched virtualization technology for consoli- dation of distributed workloads, improved availability and security to help increase business resiliency, and just-in- time management of resources. The z10 BC is at the core of the enhanced System z platform and is the new face of System z.

The z10 BC has the machine type of 2098, with one model (E10) offering between one to ten confi gurable Processor Units (PUs). This model design offers increased fl exibility over the two model IBM System z9 Business Class (z9® BC) by delivering seamless growth within a single model, both temporary and permanent.

The z10 BC delivers improvements in both the granular increments and total scalability compared to previous System z midrange servers, achieved by both increasing the performance of the individual PU as well as increasing the number of PUs per server. The z10 BC Model E10 is designed to provide up to 1.5 times the total system capac- ity for general purpose processing, and over 40% more confi gurable processors than the z9 BC Model S07.

The z10 BC advances the innovation of the System z10 platform and brings value to a wider audience. It is built using a redesigned air cooled drawer package which replaces the prior “book” concept in order to reduce cost and increase fl exibility. A redesigned I/O drawer offers

higher availability and can be concurrently added or replaced when at least two drawers are installed. Reduced capacity and priced I/O features will continue to be offered on the z10 BC to help lower your total cost of acquisition. The quad core design z10 processor chip delivers higher frequency and will be introduced at 3.5 GHz which can help improve the execution of CPU intensive workloads on the z10 BC. These design approaches facilitate the high- availability, dynamic capabilities and lower cost that differ- entiate this z10 BC from other servers.

The z10 BC supports from 4 GB up to 248 GB of real customer memory. This is almost four times the maximum memory available on the z9 BC. The increased available memory on the server can help to benefi t workloads that perform better with larger memory confi gurations, such as DB2, WebSphere and Linux. In addition to the cus- tomer purchased memory, an additional 8 GB of memory is included for the Hardware System Area (HSA). The HSA holds the I/O confi guration data for the server and is entirely fenced from customer memory.

High speed connectivity and high bandwidth out to the data and the network are critical in achieving high levels of transaction throughput and enabling resources inside and outside the server to maximize application requirements. The z10 BC has a host bus interface with a link data rate of 6 GB using the industry standard Infi niBand protocol to help satisfy requirements for coupling (ICF and server-to- server connectivity), cryptography (Crypto Express2 with secure coprocessors and SSL transactions), I/O (ESCON®, FICON® or FCP) and LAN (OSA-Express3 Gigabit, 10 Gigabit and 1000BASE-T Ethernet features). High Perfor- mance FICON for System z (zHPF) also brings new levels of performance when accessing data on enabled storage devices such as the IBM System Storage DS8000.

11

Image 11
Contents IBM System z10 Business Class z10 BC Reference Guide Table of Contents Think Big, Virtually Limitless IBM System z10 Business Class z10 BC OverviewSpecial workloads, Specialty engines, affordable technology More Solutions, More AffordableNew Face Of System z Architecture operating system support ArchitectureZ10 BC Architecture Page Commitment to system integrity TPF VSEOperating System ESA/390 Linux on System zZ10 BC Page Page Z10 BC Design and Technology Memory Dimm sizes 2 GB and 4 GB Z10 BC ModelZ10 BC capacity identifiers Z10 BC Model Capacity IDs Z10 BC model upgradesCPU Measurement Facility Z10 BC PerformanceLarge System Performance Reference System I/O Configuration Analyzer Z10 BC I/O SubsystemZ10 BC Channels and I/O Connectivity Modes of Operation Concurrent UpdateSupport of Spanned Channels and Logical Partitions FCP Channels Ficon Support for Cascaded DirectorsHigh Performance Ficon improvement in performance FCP increased performance for small block sizesScsi IPL now a base function FCP Full fabric connectivityPlatform and name server registration in Ficon channel Preplanning and setup of SAN for a System z10 environmentProgram Directed re-IPL DistanceFicon Express enhancements for Storage Area Networks NPort ID VirtualizationOSA-Express3 the newest family of LAN adapters Serviceability EnhancementsFeature Infrastructure Ports per Ficon Link Incident ReportingOSA-Express2 availability OSA-Express3 Ethernet features Summary of benefitsOSA-Express3 10 Gigabit Ethernet LR FeaturesPurpose/Traffic TypeOSA-Express3-2P 1000BASE-T Ethernet OSA-Express3-2P Gigabit Ethernet SXFour-port exploitation on OSA-Express3 GbE SX and LX OSA-Express3 1000BASE-T EthernetNetwork Traffic Analyzer Dynamic LAN idle for z/OS Link aggregation for z/VM in Layer 2 modeOSA Layer 3 Virtual MAC for z/OS Layer 2 transport mode When would it be used?OSA-Express3 and OSA-Express2 OSN OSA for NCP Direct Memory Access DMAHardware data router IBM Communication Controller for Linux CCLOSA/SF Virtual MAC and Vlan id Display Capability OSA Integrated Console ControllerRemove L2/L3 LPAR-to-LPAR Restriction HiperSockets HiperSockets Enhancement for zIIP Exploitation CP Assist for Cryptographic Function Cpacf Security CryptographyCan Do IT securely Crypto Express2-1P Enhancements to CP Assist for Cryptographic Func Tion CpacfConfigurable Crypto Express2 Secure Key AES Support for ISOSupport for RSA keys up to 4096 bits Dynamically add crypto to a logical partitionSmart Card Reader Support for 13- thru 19-digit Personal Account NumbersTKE 5.3 workstation Enhancement with TKE 5.3 LICRemote Key Loading Benefits TKE additional smart cards new featureSystem z10 BC cryptographic migration Remote Loading of Initial ATM KeysCapacity on Demand Temporary Capacity On Demand CapabilitiesAmendment for CBU Tests Capacity Provisioning System z9 System z10 OS Capacity provisioning allows you to set up rulesRAS Design Focus Reliability, Availability, and Serviceability RASRedundant I/O Interconnect Enhanced Driver MaintenanceAvailability Functions Hardware System Area HSATransparent Sparing Dynamic Oscillator SwitchoverConcurrent Memory Upgrade Service EnhancementsIBM Systems Director Active Energy Manager Power MonitoringPower Estimation Tool Environmental EnhancementsCoupling Facility Control Code Cfcc Level Improved service time with Coupling Facility DuplexParallel Sysplex Cluster Technology System-Managed CF Structure Duplexing Coupling Facility Configuration AlternativesIntroducing long reach InfiniBand coupling links Parallel Sysplex Coupling ConnectivityCoupling Connectivity for Parallel Sysplex Server Time Protocol enhancements Z10 Coupling Link OptionsTime synchronization and time accuracy on z10 BC Server Time Protocol STPPreview Improved STP System Management with Continuous Availability of NTP servers used as Exter Enhanced STP recovery when Internal Battery FeatureApplication Programming Interface API to automate Internal Battery Feature RecommendationHMC/SE Console Messenger HMC System SupportFamily Machine Type Internet Protocol, Version 6 IPv6HMC z/VM Tower System Management Enhancements Enhanced installation support for z/VM using the HMCImplementation Services for Parallel Sysplex Gdps Fiber Quick Connect for Ficon LX EnvironmentsPhysical Planning Z10 BC Physical CharacteristicsZ10 BC System Power Z10 BC Highlights and Physical Dimensions Z9 BCZ10 BC Concurrent PU Conversions Z10 BC Configuration DetailZ10 BC IBF hold uptime Drawer Drawers Z10 BC Model StructureZ10 BC Minimum Maximum IBFZ890 Coupling Facility CF Level of SupportStatement of Direction Resource Link PublicationsFollowing Redbook publications are available now Available in the Library section of Resource LinkZSO03021-USEN-02