z10 BC Configuration Detail
Features | Min # | Max # | Max | Increments | Purchase |
| Features | Features | Connections | per Feature | Increments |
|
|
|
|
|
|
0 (1) | 32 | 480 channels | 16 channels | 4 channels | |
ESCON |
|
|
| 1reserved as |
|
|
|
|
| as a spare |
|
|
|
|
|
|
|
FICON | 0 (1) | 32 | 64/128* | 2/4* | 2/4* |
Express4* |
|
| channels | channels | channels |
|
|
|
|
|
|
FICON | 0 (1) | 20 | 80 channels | 4 channels | 4 channels |
Express2** |
|
|
|
|
|
|
|
|
|
|
|
FICON | 0 (1) | 20 | 40 channels | 2 channels | 2 channels |
Express** |
|
|
|
|
|
|
|
|
|
|
|
0 (1) | 6 | 12 links (2) (3) | 2 links | 1 link | |
0 (1) | 12 | 48 links (2) | 4 links | 1 link | |
| 0 (1) |
| 12 links (2) |
|
|
1x PSIFB | 6 | 2 links | 2 links | ||
12x PSIFB | 0 (1) | 6 | 12 links (2) (3) | 2 links | 2 links |
|
|
|
|
|
|
OSA- | 0 | 24 | 48/96* | 2 or 4 | 2 ports/ |
Express3* |
|
| ports |
| 4 ports |
|
|
|
|
|
|
OSA- | 0 | 24 | 24/48 | 1 or 2 | 2 ports/ |
Express2** |
|
| ports |
| 1 port |
|
|
|
|
|
|
|
|
|
|
| 2* |
Crypto | 0 | 8 | 8/16 | 1/2* | |
Express2* |
|
| adapters | adapters | adapters (4) |
|
|
|
|
|
|
1)Minimum of one I/O feature (ESCON, FICON) or Coupling Link (PSIFB,
2)The maximum number of external Coupling Links combined cannot exceed 56 per server. There is a maximum of 64 coupling link CHPIDs per server (ICs,
3)
4)Initial order of Crypto Express2 is 2/4
Each
*FICON
**Available only when carried forward on an upgrade from z890 or or z9 BC. Limited availability for
z10 BC Concurrent PU Conversions
•Must order (characterize one PU as) a CP, an ICF or an
IFL
•Concurrent model upgrade is supported
•Concurrent processor upgrade is supported if PUs are available
–Add CP, IFL, unassigned IFL, ICF, zAAP, zIIP or optional SAP
•PU Conversions
–Standard SAP cannot be converted to other PU types
To | CP | IFL | Unassigned | ICF | zAAP | zIIP | Optional |
From |
|
| IFL |
|
|
| SAP |
|
|
|
|
|
|
|
|
CP | X | Yes | Yes | Yes | Yes | Yes | Yes |
|
|
|
|
|
|
|
|
IFL | Yes | X | Yes | Yes | Yes | Yes | Yes |
|
|
|
|
|
|
|
|
Unassigned | Yes | Yes | X | Yes | Yes | Yes | Yes |
IFL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ICF | Yes | Yes | Yes | X | Yes | Yes | Yes |
|
|
|
|
|
|
|
|
zAAP | Yes | Yes | Yes | Yes | X | Yes | Yes |
|
|
|
|
|
|
|
|
zIIP | Yes | Yes | Yes | Yes | Yes | X | Yes |
|
|
|
|
|
|
|
|
Optional | Yes | Yes | Yes | Yes | Yes | Yes | X |
SAP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Exceptions: Disruptive if ALL current PUs are converted to different types may require individual LPAR disruption if dedicated PUs are converted.
62