Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) Link Quality, Forcing Duplex Mode

Page 11

Chapter 3: Configuration

Traps can also be set in the iView2 software. A Trap will be generated on any Loss of Signal (LOS); but more importantly, the end user can set a VDSL Quality Level that will generate a trap if the line fails below the assigned level.

3.8 LINK Quality

Link Quality is defined by 4 values: 8,4,2,1. The four green LEDs form a binary code indicating the maximum bandwidth the VDSL line can support. The appropriate LED will light once the line quality is dynamically detected. This represents the maximum Downstream data rate (Kbps) the line can support based upon line noise and line length. The Upstream rate will be less based on the Base Plan used.

3.9 Forcing Duplex Mode

The DATA port can be manually configured on the HDMCII VDSL2 LAN Extender Module (Extended Temp) for Half- or Full-Duplex operation. Before manually setting the duplex mode, disable Auto Negotiation (Set DIP Switch #5 to OFF).

Full-Duplex for the DATA port is configured by setting DIP Switch #8 to the OFF position (default).

Half-Duplex for the DATA port is configured by setting DIP Switch #8 to the ON position.

LMC5601C-VDSL2 724-746-5500 blackbox.com

Page 11

Image 11
Contents Hdmcii VDSL2 LAN Extender Module Extended Temp FCC and Industry Canada RF Interference Statements FCC and IC RFI StatementsBlackbox.com Certifications CertificationsLMC5601C-VDSL2 724-746-5500 blackbox.com Table of Contents Hdmcii VDSL2 LAN Extender Module Extended Temp Part Numbers DescriptionSpecifications SpecificationsOverview DIP Switch Settings ConfigurationConfiguration Data Port Features Host CO Module ConfigurationRemote CPE Module Configuration Snmp Management Auto NegotiationSelective Advertising Link Quality Forcing Duplex ModeFlow Control Forcing the Data Port SpeedInstall the Hdmcii VDSL2 LAN Extender Module Extended Temp Install the Hdmcii VDSL2 LAN Extender Module Extended Temp2-1 OperationOperation LED Operation FunctionHdmcii VDSL2 LAN Extender Module Extended Temp Rate/Reach Pin Pin SignalRJ-11 Port Pinout Fault Loopback FL Link Fault Pass-ThroughTroubleshooting TroubleshootingContacting Black Box Fiber Optic Cleaning Guidelines Fiber Optic Cleaning GuidelinesElectrostatic Discharge Precautions Electrostatic Discharge PrecautionsPage LMC5601C-VDSL2 724-746-5500 blackbox.com LMC5601C-VDSL2 Rev