Black Box LMC5601C-VDSL2 manual Operation LED Operation, Function, 2-1

Page 14

Chapter 5: Operation

5. Operation

5.1 LED Operation

Each module features diagnostic LEDs that provide information on features and ports.

LED

Function

 

VDSL2

RAI

The Remote Alarm Indication LED is YELLOW

 

when the unit at the far end of the Unit has an alarm

FL

Fault Loopback will be ON GREEN if this function is

 

enabled and BLINK if it is actively inhibiting the

 

Ethernet port due to a LOS of the VDSL line

LOS

The LOS LED is RED when the VDSL port is down.

ER

The ERROR LED will Blink YELLOW when the

 

VDSL line receives a symbol error. ON if the VDSL

 

bandwidth falls below the user defined level.

 

LINK QUALITY

8-4-2-1

These 4 GREEN LEDs form a binary code

 

indicating the MAX bandwidth the VDSL line can

 

support.

 

DATA

OVF

Overflow LED will Blink YELLOW when frames are

 

lost due to congestion on the VDSL line.

LFPT

Link Fault Pass-Through will be ON GREEN if this

 

function is enabled and BLINK if it is actively

 

inhibiting the Ethernet port due to a LOS of the far

 

end TX line.

LOS

The LOS LED is RED when the DATA port is down.

ER

The ER LED is YELLOW when the DATA port

 

receives an error.

The VDSL2 will generate a Trap (when enabled in iView2 ) whenever a Loss of Signal (LOS) occurs. In addition, the end user can set a VDSL Quality Level that will generate a Trap if the line fails below that set level.

Page 14

724-746-5500 blackbox.com

LMC5601C-VDSL2

Image 14
Contents Hdmcii VDSL2 LAN Extender Module Extended Temp FCC and Industry Canada RF Interference Statements FCC and IC RFI StatementsBlackbox.com Certifications CertificationsLMC5601C-VDSL2 724-746-5500 blackbox.com Table of Contents Part Numbers Description Hdmcii VDSL2 LAN Extender Module Extended TempSpecifications SpecificationsOverview DIP Switch Settings ConfigurationConfiguration Data Port Features Host CO Module ConfigurationRemote CPE Module Configuration Snmp Management Auto NegotiationSelective Advertising Forcing Duplex Mode Link QualityForcing the Data Port Speed Flow ControlInstall the Hdmcii VDSL2 LAN Extender Module Extended Temp Install the Hdmcii VDSL2 LAN Extender Module Extended TempFunction OperationOperation LED Operation 2-1Hdmcii VDSL2 LAN Extender Module Extended Temp Rate/Reach Pin Pin SignalRJ-11 Port Pinout Link Fault Pass-Through Fault Loopback FLTroubleshooting TroubleshootingContacting Black Box Fiber Optic Cleaning Guidelines Fiber Optic Cleaning GuidelinesElectrostatic Discharge Precautions Electrostatic Discharge PrecautionsPage LMC5601C-VDSL2 724-746-5500 blackbox.com LMC5601C-VDSL2 Rev