Chapter 4: Install the HDMCII VDSL2 LAN Extender Module (Extended Temp)
4. Install the HDMCII VDSL2 LAN Extender Module (Extended Temp)
Before installing an HDMCII VDSL2 LAN Extender Module (Extended Temp), set the options using the DIP Switches (refer to the DIP Switch Settings section for more information).
Install HDMCII VDSL2 LAN Extender Module (Extended Temp) in any Black Box
To install a module, remove the blank brackets (if present) covering the slots where you will install the module by removing the screws on the outside edges of the bracket. Slide the module into the chassis, via the card guides, until the module is seated securely in the connector. Secure the module to the chassis by tightening the captive screw. Save any blanks removed during installation for future use.
Remote CPE modules can be installed in a managed or unmanaged chassis. Remote CPE modules can only be managed from the connected Host CO HDMCII VDSL2 LAN Extender Module (Extended Temp) installed in a managed chassis. The user should always set remote DIP Switches to provide a base value under VDSL line fault conditions. In addition, some features may not be software configurable on the remote unit. After setting the DIP Switches, install the HDMCII VDSL2 LAN Extender Module (Extended Temp). Once the VDSL line is established, the line can be monitored and configured through the iView2 management software available for download at ftp://ftp.blackbox.com/anonymous/lan/Managed%20Media%20Converters/L MC5200a/.