Transition Networks SUBTF10XX-1XX-MX specifications Troubleshooting, VAC, 50/60Hz

Page 13

SIBTF10xx-1xx-Mx

Technical Specification -- continued

EMC Type Tests -- Continued

Standard

Description

Compliance Level

Remarks

 

 

 

 

IEEE1613, Power Substation Testing -- Continued

 

 

 

 

 

 

IEEE1613, Clause 7.3.2

 

Class 2 transverse mode

Surge fast transient

 

 

Class 1 common mode

waveform – power AC

 

 

 

 

 

 

Class 2 transverse mode

Surge fast transient

 

 

Class 1 common mode

waveform – power DC

 

 

 

 

 

 

Class 1 common mode

Surge fast transient

 

 

 

waveform – relay port

 

 

 

 

 

 

Class 1 common mode

Surge fast transient

 

 

 

waveform – Ethernet 10

 

 

 

Mbps

 

 

 

 

 

 

Class 1 common mode

Surge fast transient

 

 

 

waveform – Ethernet 100

 

 

 

Mbps

 

 

 

 

IEEE1613, Clause 8

 

Class 2

Radio frequency

 

 

 

susceptibility

 

 

 

 

IEEE1613, Clause 9

 

Class 1

ESD contact discharge 8kV

 

 

 

 

Troubleshooting

If the industrial switch fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:

1.

Is the “PRI” (primary power) LED illuminated?

 

NO

Ensure the power source is the proper voltage (48–170 VDC or 90–125

 

 

 

VAC, 50/60Hz).

 

 

Ensure that the positive, negative, and ground wires from the power

 

 

source are properly connected to the primary inputs.

 

Contact Technical Support:

US/Canada: 1-800-260-1312,

 

 

 

International: 00-1-952-941-7600.

 

YES

 

 

Proceed to step 2.

2.(SIBTF10xx10x-MR models only) is the “AUX” (auxiliary power) LED illuminated?

NO

If the device does not have an auxiliary power source, proceed to step 3.

Ensure the power source is the proper voltage (48–170 VDC or 90–125 VAC, 50/60Hz).

Ensure that the positive, negative, and ground wires from the power source are properly connected to the auxiliary inputs.

Contact Technical Support: US/Canada: 1-800-260-1312, International: 00-1-952-941-7600.

YES

Proceed to step 3.

Troubleshooting -- continued

3.Is the “FAULT” LED illuminated?

NO

Proceed to step 4.

YES

Contact Technical Support: US/Canada: 1-800-260-1312, International:

00-1-952-941-7600.

4.For each port with a cable installed is either the “10MB” or the “100MB” LED illuminated?

YES

Proceed to step 5.

NO

For each port with a cable installed and its LED is OFF, check the cable for proper connection.

For the fiber ports, verify that the TX and RX cables on the SIBTF10xx- 10x are connected to the RX and TX ports, respectively, on the device at the other end of the fiber cables.

Contact Technical Support: US/Canada: 1-800-260-1312, International:

00-1-952-941-7600

5.For each RJ-45 port with a cable installed (ports 1, 2, 3, and 4), check to see if the 10MB or 100MB LED is illuminated.

10MB is ON = The industrial switch has selected 10Mb/s operation.

100MB is ON = The industrial switch has selected 100Mb/s operation.

If the speed is not correct, disconnect and reconnect the cable to restart the initialization process.

Proceed to step 6.

6.For each fiber port with a cable installed, is the “FD” (full-duplex)LED illuminated?

NO

The industrial switch has selected half-duplex mode.

If the mode is not correct, disconnect and reconnect cable to restart the initialization process.

Check the cable for proper connection.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

The industrial switch has selected full-duplex mode.

If the mode is not correct, disconnect and reconnect cable to restart the initialization process.

Check the cable for proper connection.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

24

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

25

Image 13
Contents 130-MR 110-MR 140-MRAvailable Models Available ModelsAvailable SIBTF10xx-140-MR and MS models Available SIBTF10xx-130-MR and MS modelsInstallation InstallationFeatures FeaturesSetting configuration switches Enclosure top view configuration switchesDIP switch settings Connecting auxiliary power Connecting primary powerDIN-Rail Internal relay connectionsMounting the enclosure to a DIN-Rail Installing copper cable Installing fiber cableOperation Copper/fiber status LEDsOperation Product FeaturesCopper/fiber status LEDs OperationReplacing the fuse Product featuresCable Specifications Cable SpecificationsCopper Cable Fiber cableTechnical Specification Technical Specifications220-240VAC, 50/60Hz installation Troubleshooting TroubleshootingVAC, 50/60Hz Compliance Information Contact UsDeclaration of Conformity EN55022, EN55024, EN61000-6-22001 & IEEE1613Trademark Notice