Transition Networks SUBTF10XX-1XX-MX specifications Enclosure top view configuration switches

Page 4

SIBTF10xx-1xx-Mx

Installation -- continued

Features -- continued

The SIBTF10xx-110-MS industrial switch includes one (1) RJ-45, twisted-pair copper port and one (1) 100 Mb fiber optic port.

The Auto-Negotiation feature on port “1” can be turned OFF and forced to a selected speed (100 Mb/s or 10 Mb/s) and duplex mode (full or half).

All SIBTF models include a primary input terminal block (TB) for 48170VDC or 90125VAC power, a 2.5A, 250V fuse, an LED power indicator, and a fault LED. The red-fault LED “ON state” indicates the microcontroller did not initialize correctly.

The “MR” models include an auxiliary power-supply terminal block—not available on “MS” models.

See Figure 3.

Figure 3: SIBTF10xx-110-MR Front Panel

Installation -- continued

Enclosure top view (configuration switches)

The SIBTF10xx-1xx-Mx has eight (8) configuration (DIP) switches located under the switch cover on top of the enclosure. See Figure 4.

Switch Position 1

Figure 4: Enclosure Top View Configuration Switches

Setting configuration switches

To set the DIP switches:

1.Using a small, phillips-head screwdriver, loosen (do not remove) the two screws that secure the cover to the switch.

2.Swing the switch cover counter-clockwise to expose the DIP switches.

3.Use a small, flathead screwdriver to set the recessed switches as required by the network application.*

4.Slide the switch cover back over the DIP switches and then secure it by tightening both screws.

*Note: Switches 1, 2, and 3 apply only to twisted-pair “copper port #1.”

6

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

7

Image 4
Contents 140-MR 130-MR 110-MRAvailable Models Available ModelsAvailable SIBTF10xx-140-MR and MS models Available SIBTF10xx-130-MR and MS modelsInstallation InstallationFeatures FeaturesEnclosure top view configuration switches Setting configuration switchesDIP switch settings Connecting primary power Connecting auxiliary powerDIN-Rail Internal relay connectionsMounting the enclosure to a DIN-Rail Installing fiber cable Installing copper cableOperation Copper/fiber status LEDsProduct Features OperationCopper/fiber status LEDs OperationProduct features Replacing the fuseCable Specifications Cable SpecificationsCopper Cable Fiber cableTechnical Specification Technical Specifications220-240VAC, 50/60Hz installation Troubleshooting TroubleshootingVAC, 50/60Hz Contact Us Compliance InformationDeclaration of Conformity EN55022, EN55024, EN61000-6-22001 & IEEE1613Trademark Notice