Transition Networks SUBTF10XX-1XX-MX specifications DIP switch settings

Page 5

SIBTF10xx-1xx-Mx

Installation -- continued

DIP switch settings

 

 

1

 

 

 

 

 

 

 

 

 

1. Port 1 copper Auto-Negotiation:

 

 

 

 

 

 

 

 

 

 

 

UP (Enabled) - Advertises switch speed and mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

capabilities to the network:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto-Negotiation E nabled

 

 

• 100Mb/s full-duplex

• 100Mb/s half-duplex,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• 10Mb/s full-duplex

• 10Mb/s half-duplex.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation -- continued

6. Link Pass-Through (model 110 only):

UP (Enable) - When Link Pass-Through is enabled, a fault on one side of the switch stops the signal and data transmission on the other side. See the detailed explanation of Link Pass-Through on page 18.

DOWN (Disable) - When Link Pass-Through is disabled, a fault on one side of the switch does not stop the signal and data transmission on the other side.

6

Link Pass- Through E nabled

Link Pass- Through Disabled

DOWN (Disabled) - Does not advertise switch speed Auto-Negotiation Disabled and mode capabilities to the network. With Auto-

Negotiate disabled switches 2 and 3 are used to set the twisted-pair speed and mode.

7. Fiber redundancy (model 130 only):

UP (Disable) - When fiber redundancy is disabled, the two fiber ports (1 and 2) act as normal bridging ports.

DOWN (Enable) - When fiber redundancy is enabled, the two fiber ports (1 and 2) are configured as

7

Redundant Fiber E nabled

2.Port 1 copper speed:

UP (100Base-TX)- Sets the twisted-pair speed to 100Base-TX.

DOWN (10Base-T)- Sets the twisted-pair speed to 10Base-T.

3.Port 1 copper duplex:

UP (Full-Duplex)- The twisted-pair cable distances are constrained by the cable requirements.

DOWN (Half-Duplex): - The twisted-pair cable distances are constrained by the 512-Bit Rule.

4.Fiber port FX 1 duplex:

UP (Full-Duplex)- The cable distances for the fiber port are constrained by the cable requirements.

DOWN (Half-Duplex)- The cable distances for the fiber port are constrained by the 512-Bit Rule.

5.Fiber port FX 2 duplex (model 130 only):

UP (Full-Duplex)- The cable distances for the fiber port are constrained by the cable requirements.

DOWN (Half-Duplex)- The cable distances for the fiber port are constrained by the 512-Bit Rule.

2

100Base-TX

10Bas e-TX

3

Full Duplex

Half Duplex

4

Full Duplex (fiber)

Half Duplex (fiber)

5

Full Duplex (fiber)

forwarding or disabled. At any given time one port will be disabled and one port will be forwarding.

8. AutoCross:

UP (Enable) - The switch will connect to a straight- through or a crossover twisted-pair copper cable automatically.

DOWN (Disable) - In the down position the straight- through or crossover twisted-pair copper cable must be installed according to the site requirements.

Redundant Fiber Disabled

8

AutoCross E nabled

AutoCross Disab led

Half Duplex (fiber)

8

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

9

Image 5
Contents 130-MR 110-MR 140-MRAvailable Models Available ModelsAvailable SIBTF10xx-140-MR and MS models Available SIBTF10xx-130-MR and MS modelsInstallation InstallationFeatures FeaturesSetting configuration switches Enclosure top view configuration switchesDIP switch settings Connecting auxiliary power Connecting primary powerMounting the enclosure to a DIN-Rail Internal relay connectionsDIN-Rail Installing copper cable Installing fiber cableOperation Copper/fiber status LEDsOperation Product FeaturesCopper/fiber status LEDs OperationReplacing the fuse Product featuresCable Specifications Cable SpecificationsCopper Cable Fiber cable220-240VAC, 50/60Hz installation Technical SpecificationsTechnical Specification VAC, 50/60Hz TroubleshootingTroubleshooting Compliance Information Contact UsDeclaration of Conformity EN55022, EN55024, EN61000-6-22001 & IEEE1613Trademark Notice