Transition Networks TN-GLC-BX-D, TN-CWDM-SFP-1xx0, TN-GLC-LH-SM, TN-GLC-BX-U, TN-GLC-T Fiber cable

Page 4

TN-GLC-xx-xx SFPs

Fiber cable

The physical characteristics must meet or exceed IEEE 802.3zspecifications.

Fiber cable -- continued

TN-GLC-FE-100FX

1300 nm multimode

TN-GLC-GE-100FX

1300 nm multimode

Singlemode fiber (recommended): Multimode fiber (recommended): Multimode fiber (optional):

TN-GLC-SX-MM

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

TN-GLC-SX-MM-2k

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

TN-GLC-LH-SM

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

TN-GLC-BX-U

TN-GLC-BX-D

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

TN-GLC-BX-U-40

TN-GLC-BX-D-40

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

TN-GLC-BX-U-60

TN-GLC-BX-D-60

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

TN-GLC-FE-100BX-U

TN-GLC-FE-100BX-D

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

9µm 62.5/125 µm

100/140, 85/140, 50/125 µm

850 nm multimode

 

min: -9.5 dBm

max: -3.5 dBm

min: -18.0 dBm

max: -1.0 dBm

8.5 dB

 

1300 nm multimode

min: -9.0 dBm

max: -1.0dBm

min: -19.0 dBm

max: -1.0 dBm

18.0 dB

 

1310 nm singlemode

min: -9.5 dBm

max: -3.0 dBm

min: -20.0 dBm

max: -3.0 dBm

10.5 dB

 

1310 nm Tx/1490 nm Rx single mode

1490 nm Tx/1310 nm Rx single mode

min: -9.0 dBm

max: -1.0 dBm

min: -21.0 dBm

max: -1.0 dBm

12.0 dB

 

1310 nm Tx/1490 nm Rx single mode

1490 nm Tx/1310 nm Rx single mode

min: -3.0 dBm

max: +2.0 dBm

min: -23.0 dBm

max: -1.0 dBm

20.0 dB

 

1310 nm Tx/1490 nm Rx single mode

1490 nm Tx/1310 nm Rx single mode

min: -2.0 dBm

max: +4.0 dBm

min: -25.0 dBm

max: -1.0 dBm

23.0 dB

 

1310 nm Tx/1550 nm Rx single mode

1550 nm Tx/1310 nm Rx single mode

min: -14.0 dBm

max: -8.0 dBm

min: -32.0 dBm

max: -0.0 dBm

18.0 dB

 

Fiber Optic Transmitter Power:

min: -23.5 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.0 dBm

max: -8.0 dBm

Link Budget:

8.5 dB

 

TN-GLC-FE-100LX

1310 nm single mode

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -0.0 dBm

Link Budget:

19.0 dB

 

TN-GLC-ZX-SM

1550 nm single mode

Fiber Optic Transmitter Power:

min: 0.0 dBm

max: +5.0 dBm

Fiber Optic Receiver Sensitivity:

min: -24.0 dBm

max: -3.0 dBm

Link Budget:

24 dB

 

TN-CWDM-SFP-1xx0

1270nm -1610nm single mode

Fiber Optic Transmitter Power:

min: 0.0 dBm

max: +5.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -3.0 dBm

Link Budget:

25 dB

 

For the most up-to-date information on the TN-GLC-xx-xx transceiver module, view the user’s guide on-line at: www.transition.com.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.

WARNING: Visible and invisible laser radiation when open. Do not stare into beam or view directly with optical instruments. Failure to observe this warning could result damage to your eyes or blindness.

WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein could result in hazardous radiation exposure.

The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.

6

Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

7

Image 4
Contents User’s Guide Installing the SFP transceiver InstallationInstalling copper cables Cable Specification Installing the fiber cablesFiber cable Technical Specification Technical supportTransition now Web-Based seminars MailCompliance Information CE Mark IEC-60825 FDA 21 CFR 1040.10Trademark notice