IBM NH2025-10 NBase-Xyplex Snmp Support, Snmp basic configuration, Stopping the Frame Generation

Page 65

Configuring, Modifying, and Monitoring the Unit

Example

SYS_console>start-fg 1 9 0 10

SYS_console>

Stopping the Frame Generation

stop-fg

This command stops the Ethernet frame generator.

SNMP

This section explains how to use the Simple Network Management Protocol (SNMP) to manage LAN Switch Processors. It assumes that you are using an SNMP-based network management software application such as NBase-Xyplex MegaVision ™ to manage the switches. Hereafter, this section refers to your network management application as a Network Operations Center (NOC). Additionally, this section describes the RMON (Remote Monitoring) application and the type of network management applications that enable you to use RMON.

NBase-Xyplex SNMP Support

SNMP is an Internet standard protocol, defined by the Internet Engineering Task Force (IETF) Request for Comment (RFC) 1157, which specifies how network management information is carried through a network. NBase-Xyplex switches support SNMP by implementing an SNMP agent. The agent stores Management Information Base (MIB) data and makes it available when requested through SNMP Set, Get, and Get_Next requests.

In addition, NBase-Xyplex switches generate SNMP Trap messages. Traps are notices that the switch sends to an SNMP manager indicating that a specific event has occurred, or that the condition of a unit has changed significantly.

SNMP basic configuration

To enable your NOC to communicate with a NBase-Xyplex switch, you must assign it an IP address. Use the following command to do this:

set-ip-cfg ip-address ip-mask ip-broadcast

The address you assign must be valid for the network connected to the switch. In a routed network, depending on the switch location, you also need to assign a subnet mask and gateway, as follows:

set-gatew ip-gateway-address

To make sure that your NOC can exchange information with the switch, Ping the switch from the NOC.

57

Image 65
Contents Page Page CE Mark Standards ComplianceFCC Notice Page Contents Configuring, Modifying, and Monitoring the Unit Iii Statistics General View OverviewNetwork Management Systems ApplicationsManagement Feature SummaryPerformance/Configuration Page Installing the Unit Installing and Setting Up the UnitRack Mounting Front PanelRear Panel Installing Modules in the UnitEM2003-2FO Modules for NHEM2003-1GE Input Supply Connecting Power to the UnitEM2003-8TP Em2003-2GEGrounding Connecting Ethernet DevicesConnecting Your Network Page Logging Into the Command Line Interface Connecting to the Management PortSetting the IP Address Getting StartedAccessing the Command Line Interface Remotely Verifying the InstallationSYSconsole set-ip SYSconsole ping 192.1.1.1Command Conventions Using the Command Line InterfaceCommand Line Help Getting Command Parameter HelpSYSconsole ping 129.1.1.7 ? Getting Command Group HelpUsing Command Wildcards SYSconsoleget-co Retrieving Command HistoryConnectivity matrix Nonexistent Command Command Line ErrorsSYSconsole pin Command ‘pin’ not found Incorrect Number of ParametersConsole Commands Configuring, Modifying, and Monitoring the UnitCompletes command Help-kbdBanner LoginClear LogoutSet-passwd Sys-stat System CommandsCold-reset Warm-resetGet-stst-level Set-stst-levelSet-tftp-srvr Get-tftp-srvrSet-tftp-mode Get-tftp-modeIP Configuration IP CommandsGet-ip Get-ip-cfgSet-ip Setting an IP addressSet-ip-cfg IP broadcast SYSconsoleBootp Configuration Erasing an IP ConfigurationConfiguring a Gateway Get-arp-tbl Address Resolution Protocol ARPDel-arp-entry Add-arp-entryDisplaying the Port Configuration Port configurationGet-arp-stats Get-port-cfg dport pipe allSet-port-state Setting the port configurationSet-port-cfg Set-fctrl Setting the flow controlGet-fctrl Setting the EtherChannel Configuration Getting the EtherChannel ConfigurationEtherChannel Get-ec-tblSet Port Priority Deleting the EtherChannel Configuration del-ecPort Priority Get Port Priority Modifying the Switch PolicyVlan Priority Get-priority-port-cfgHow the STP Topology Stabilizes Spanning Tree Protocol STPSpanning Tree Parameters Selecting a Designated Switch/BridgeRoot Bridge Manually Designating a Root BridgeSpanning Tree Commands Using STP to Manage Redundant LinksTopology Change Notification Bpdu Spanning Tree and Vlan restrictionsViewing Bridge Parameters Configuring the BridgeGet-st-bcfg Max Age set-br-maxageSetting Port Configuration Viewing the Port ConfigurationHello Time set-br-hellot Get-st-pcfgSet-prt-pcost dport pathcost Set-prt-enb port-number enabledisableSet-prt-prio 4 Priority was changed for port SYSconsole Aging Configuration Switching CommandsLearning Table Get-lt-ageGet-lt-16 Get-lt-entryFind-lt-addr Adding Static Entries Deleting EntriesSetting the VBC mode Viewing the VBC ModeVirtual Broadcast Domain Creating VBC DomainsGet-vbc-matrix Viewing VBC MatrixGet-vbc-tbl Deleting a VBC Virtual NetworkingDel-vbc-domain Del-vbc-domain runnvram domainidSetting the Vlan Mode Viewing the Vlan ModeSYSconsoleset-vlan-mode run tag Set run Vlan mode tag OK Important ConsiderationsViewing the Isvlan Mode Inter-Switch Vlan or IsvlanTag Field Format Principles of IsvlanServer Port Setting a Tagged PortRemoving a Tagged Port Creating a Server PortCreating a Vlan Viewing Vlan ConfigurationRemoving a Server Port Del-vlan Deleting a VlanGet-vlan-entry Viewing the Management Tag Vlan ManagementModifying the Management Tag Deleting the Management from a VlanPhysical configuration schema VLAN, Server-port, Example of ConfigurationVlan Server Port ConfigurationApplication Creating a Vlan with Port ManagementPayroll Vlan Configuration Vlan ConfigurationFinance Vlan Configuration Checking the ConfigurationPing Commands Utilities CommandsPort mirroring PingSaving the Configuration Setting the Monitoring PortMonitoring with monitor Stopping MonitoringErasing the Nvram configuration Viewing the Nvram ConfigurationSetting the Frame Generator Frame GeneratorStopping the Frame Generation Snmp basic configurationNBase-Xyplex Snmp Support Setting the Read or Write Community Snmp Community String CommandsViewing the Community String Get-commViewing the Authentication Trap Status Setting Authentication TrapsSetting the Authentication Trap Snmp TrapsAdd-trap Configuring the Trap StationsGet-traps Example Statistics Clearing the Switch CountersGetting Collisions on a Port Clr-cntGetting the Packet Size Distribution Rmon StatisticsGetting Rmon Statistics Group for a Port Getting the Management Counters Page Trouble Shooting Mailservice@mrv.com Commands Quick Reference ARP Commands Ping CommandsEtherChannel Commands Snmp CommandsVirtual LAN Commands Switching Database CommandsPort Monitoring Port Configuration CommandsSwitching Statistics Commands Spanning Tree Commands Page Snmp System Default ValuesPage Download Procedure Server mode Appendix B Firmware Download Using TftpDownload Procedure Client Mode ∙ set-tftp-mode client Tftp Recovery Breaking into the BootROMCompatibility Appendix C Technical SpecificationsStandards Compliance

NH2025-10 specifications

The IBM NH2025-10 is a powerful and versatile network appliance designed to meet the growing demands of modern IT infrastructures. It serves as a cornerstone for businesses seeking to enhance their networking capabilities, streamline operations, and leverage advanced technologies. Built with a focus on reliability and performance, the NH2025-10 packs a wide range of features that cater to various use cases, from data centers to enterprise environments.

At the heart of the NH2025-10 is its robust hardware architecture, which integrates high-speed processors and ample memory resources. This combination ensures that the device can handle significant data throughput, making it an ideal solution for organizations that require fast and efficient data processing. Its state-of-the-art virtualization capabilities enable multi-tenancy, allowing organizations to run multiple applications and services seamlessly.

One standout feature of the NH2025-10 is its advanced security framework. It incorporates tools for threat detection and mitigation, firewall protection, and secure access controls. These features work in tandem to provide a fortified network environment, critical for safeguarding sensitive data. With an intuitive user interface, administrators can easily configure and manage security policies, ensuring compliance with industry regulations.

The NH2025-10 also supports cutting-edge networking technologies, including Software-Defined Networking (SDN) and Network Function Virtualization (NFV). These technologies enhance flexibility and scalability, allowing businesses to adapt their networks as requirements evolve without substantial hardware upgrades. The integration of machine learning algorithms further optimizes network performance, offering predictive analytics that can preemptively address potential issues.

In terms of connectivity, the device is equipped with multiple ports, including 10 Gigabit Ethernet and support for various media types, ensuring compatibility with existing infrastructure. This flexibility makes integration straightforward, allowing organizations to derive maximum value from their investments while minimizing disruption to ongoing operations.

Moreover, the NH2025-10 is designed with energy efficiency in mind. Its innovative thermal management ensures optimal performance with reduced power consumption, aiding organizations in their sustainability efforts.

Overall, the IBM NH2025-10 stands as a comprehensive solution for entities looking to elevate their networking strategies. Its combination of advanced features, security protocols, and adaptive technologies positions it as a vital asset in today's increasingly digital landscape.