Technical Specifications

Compatibility

The 2025-10 is compatible with the following: IEEE 802.3; IEEE 802.3u (Fast Ethernet); 802.1q; IEEE 802.1d (Bridge/Spanning Tree), Ethernet MIB, BRIDGE MIB, RMON (Groups 1,2,3,9), IEEE 802.3x (Flow Control)

Electrical

 

 

 

Voltage

100 - 240 VAC

 

 

Frequency

50 - 60 Hz

 

 

Power Consumption 40W

 

 

Connectors

 

 

 

STP

RJ-45 shielded

 

 

RS-232

DB-9

 

 

Optical

 

 

 

1000Base-FX (SX, LX)

 

 

SX/M

850nm;

0-300 m

MM, DSC

LX/M

1310nm;

0-500 m

MM, DSC

LX/S1

1310nm;

0-6 km

SM, DSC

LX/S2

(DFB)1550nm;

0-20 km

SM, DSC

LX/S3

(DFB)1550nm;

0-50 km

SM, DSC

Learning Table 12K MAC addresses

Boot and Configuration

NVRAM configuration loaded on power up.

Physical

 

 

H x W x D

6.55 x 44.06 x 33.0 cm

2.6” (1.5U) x 17.3” x 13”

Weight

3.6 kg

8 lb.

77

Image 85
Contents Page Page FCC Notice Standards ComplianceCE Mark Page Contents Configuring, Modifying, and Monitoring the Unit Iii Statistics General View OverviewNetwork Management Systems ApplicationsPerformance/Configuration Feature SummaryManagement Page Installing the Unit Installing and Setting Up the UnitRack Mounting Front PanelRear Panel Installing Modules in the UnitEM2003-1GE Modules for NHEM2003-2FO Input Supply Connecting Power to the UnitEM2003-8TP Em2003-2GEConnecting Your Network Connecting Ethernet DevicesGrounding Page Logging Into the Command Line Interface Connecting to the Management PortSetting the IP Address Getting StartedAccessing the Command Line Interface Remotely Verifying the InstallationSYSconsole set-ip SYSconsole ping 192.1.1.1Command Conventions Using the Command Line InterfaceCommand Line Help Getting Command Parameter HelpUsing Command Wildcards Getting Command Group HelpSYSconsole ping 129.1.1.7 ? Connectivity matrix Retrieving Command HistorySYSconsoleget-co Nonexistent Command Command Line ErrorsSYSconsole pin Command ‘pin’ not found Incorrect Number of ParametersConsole Commands Configuring, Modifying, and Monitoring the UnitCompletes command Help-kbdBanner LoginClear LogoutSet-passwd Sys-stat System CommandsCold-reset Warm-resetGet-stst-level Set-stst-levelSet-tftp-srvr Get-tftp-srvrSet-tftp-mode Get-tftp-modeIP Configuration IP CommandsGet-ip Get-ip-cfgSet-ip Setting an IP addressSet-ip-cfg IP broadcast SYSconsoleConfiguring a Gateway Erasing an IP ConfigurationBootp Configuration Get-arp-tbl Address Resolution Protocol ARPDel-arp-entry Add-arp-entryDisplaying the Port Configuration Port configurationGet-arp-stats Get-port-cfg dport pipe allSet-port-cfg Setting the port configurationSet-port-state Get-fctrl Setting the flow controlSet-fctrl Setting the EtherChannel Configuration Getting the EtherChannel ConfigurationEtherChannel Get-ec-tblPort Priority Deleting the EtherChannel Configuration del-ecSet Port Priority Get Port Priority Modifying the Switch PolicyVlan Priority Get-priority-port-cfgHow the STP Topology Stabilizes Spanning Tree Protocol STPSpanning Tree Parameters Selecting a Designated Switch/BridgeRoot Bridge Manually Designating a Root BridgeSpanning Tree Commands Using STP to Manage Redundant LinksTopology Change Notification Bpdu Spanning Tree and Vlan restrictionsViewing Bridge Parameters Configuring the BridgeGet-st-bcfg Max Age set-br-maxageSetting Port Configuration Viewing the Port ConfigurationHello Time set-br-hellot Get-st-pcfgSet-prt-prio 4 Priority was changed for port SYSconsole Set-prt-enb port-number enabledisableSet-prt-pcost dport pathcost Aging Configuration Switching CommandsLearning Table Get-lt-ageGet-lt-16 Get-lt-entryFind-lt-addr Adding Static Entries Deleting EntriesSetting the VBC mode Viewing the VBC ModeVirtual Broadcast Domain Creating VBC DomainsGet-vbc-tbl Viewing VBC MatrixGet-vbc-matrix Deleting a VBC Virtual NetworkingDel-vbc-domain Del-vbc-domain runnvram domainidSetting the Vlan Mode Viewing the Vlan ModeSYSconsoleset-vlan-mode run tag Set run Vlan mode tag OK Important ConsiderationsViewing the Isvlan Mode Inter-Switch Vlan or IsvlanTag Field Format Principles of IsvlanServer Port Setting a Tagged PortRemoving a Tagged Port Creating a Server PortRemoving a Server Port Viewing Vlan ConfigurationCreating a Vlan Get-vlan-entry Deleting a VlanDel-vlan Viewing the Management Tag Vlan ManagementModifying the Management Tag Deleting the Management from a VlanPhysical configuration schema VLAN, Server-port, Example of ConfigurationVlan Server Port ConfigurationApplication Creating a Vlan with Port ManagementPayroll Vlan Configuration Vlan ConfigurationFinance Vlan Configuration Checking the ConfigurationPing Commands Utilities CommandsPort mirroring PingSaving the Configuration Setting the Monitoring PortMonitoring with monitor Stopping MonitoringErasing the Nvram configuration Viewing the Nvram ConfigurationSetting the Frame Generator Frame GeneratorNBase-Xyplex Snmp Support Snmp basic configurationStopping the Frame Generation Setting the Read or Write Community Snmp Community String CommandsViewing the Community String Get-commViewing the Authentication Trap Status Setting Authentication TrapsSetting the Authentication Trap Snmp TrapsGet-traps Example Configuring the Trap StationsAdd-trap Statistics Clearing the Switch CountersGetting Collisions on a Port Clr-cntGetting Rmon Statistics Group for a Port Rmon StatisticsGetting the Packet Size Distribution Getting the Management Counters Page Trouble Shooting Mailservice@mrv.com Commands Quick Reference ARP Commands Ping CommandsEtherChannel Commands Snmp CommandsVirtual LAN Commands Switching Database CommandsSwitching Statistics Commands Port Configuration CommandsPort Monitoring Spanning Tree Commands Page Snmp System Default ValuesPage Download Procedure Client Mode Appendix B Firmware Download Using TftpDownload Procedure Server mode ∙ set-tftp-mode client Tftp Recovery Breaking into the BootROMCompatibility Appendix C Technical SpecificationsStandards Compliance

NH2025-10 specifications

The IBM NH2025-10 is a powerful and versatile network appliance designed to meet the growing demands of modern IT infrastructures. It serves as a cornerstone for businesses seeking to enhance their networking capabilities, streamline operations, and leverage advanced technologies. Built with a focus on reliability and performance, the NH2025-10 packs a wide range of features that cater to various use cases, from data centers to enterprise environments.

At the heart of the NH2025-10 is its robust hardware architecture, which integrates high-speed processors and ample memory resources. This combination ensures that the device can handle significant data throughput, making it an ideal solution for organizations that require fast and efficient data processing. Its state-of-the-art virtualization capabilities enable multi-tenancy, allowing organizations to run multiple applications and services seamlessly.

One standout feature of the NH2025-10 is its advanced security framework. It incorporates tools for threat detection and mitigation, firewall protection, and secure access controls. These features work in tandem to provide a fortified network environment, critical for safeguarding sensitive data. With an intuitive user interface, administrators can easily configure and manage security policies, ensuring compliance with industry regulations.

The NH2025-10 also supports cutting-edge networking technologies, including Software-Defined Networking (SDN) and Network Function Virtualization (NFV). These technologies enhance flexibility and scalability, allowing businesses to adapt their networks as requirements evolve without substantial hardware upgrades. The integration of machine learning algorithms further optimizes network performance, offering predictive analytics that can preemptively address potential issues.

In terms of connectivity, the device is equipped with multiple ports, including 10 Gigabit Ethernet and support for various media types, ensuring compatibility with existing infrastructure. This flexibility makes integration straightforward, allowing organizations to derive maximum value from their investments while minimizing disruption to ongoing operations.

Moreover, the NH2025-10 is designed with energy efficiency in mind. Its innovative thermal management ensures optimal performance with reduced power consumption, aiding organizations in their sustainability efforts.

Overall, the IBM NH2025-10 stands as a comprehensive solution for entities looking to elevate their networking strategies. Its combination of advanced features, security protocols, and adaptive technologies positions it as a vital asset in today's increasingly digital landscape.