LEDs | Features |
DIMM 4B DIMM 4A
DIMM 3B DIMM 3A
DIMM 2B DIMM 2A
DIMM 1B DIMM 1A
DIMM 4D
DIMM 4C
DIMM 3D
DIMM 3C
DIMM 2D
DIMM 2C
DIMM 1D
DIMM 1C
L
Figure 6: LEDs on the riser card
LED s A, B and C are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server has been opened.
If the server has been powered off
The LEDs have the following meaning:
LED | Anzeige | Bedeutung | ||
|
|
|
| |
A - CSS | yellow | indicates a prefailure | ||
(Customer Self |
|
|
| |
| yellow flashing | indicates a failure | ||
Service) | ||||
|
| |||
|
|
| ||
B - GEL | orange | indicates a prefailure | ||
(Global Error |
|
|
| |
| orange | indicates a failure. Reasons for a failure | ||
LED) | ||||
flashing | may be: | |||
|
| |||
|
|
| - overheating of one of the sensors | |
|
|
| - sensor defect | |
|
|
| - fan defect | |
|
|
| - CPU error | |
|
|
| - voltage incorrect | |
|
|
| - Software detected an error | |
|
|
| ||
C - Identification | blue | server is identified via ServerView | ||
|
|
|
|
26 | Technical Manual | D2529 (TX300 S4) |