IBM 4SB, 9TX, 9TS, 9QX, 9QS, 900, 4SA, 42P, 42X, 200, 42E, 42S, 4QS, 4QX manual Line cords, Power cables

Page 173

Height

43 mm (1.7 in.)

 

 

Width

192 mm (7.5 in.)

 

 

Depth

221 mm (8.7 in.)

 

 

Weight

1.6 kg (3.5 lbs)

 

 

Operating temperatures

10° C–35° C (50° F–95° F) at 0–914 m (0–3000 ft)

 

10° C–32 ° C (50° F–90° F° ) at 914–2133 m (3000–7000 ft)

 

 

Operating humidity

8–80% (non-condensing)

 

 

Rated voltage

100–120 V ac, 30 A, single-phase

 

200–240 V ac, 30 A, single-phase

 

200–240 V ac, 32 A, single-phase

 

200–240 V ac, 30 A, single-phase

 

380–415 V ac, 32 A, single-phase

 

 

Rated frequency

50–60 Hz

 

 

Maximum power rating

4800-6000 VA

 

 

Power inlet

One fixed line cord

 

 

Power outlets

Three IEC 320-C19 outlets rated at 16 A (VDE) / 20 A

 

(UL/CSA)

 

 

Line cords

The 2.5 m (8.2 ft) fixed line cord on the Rack PDU determines the connectivity of the Rack PDU. The following table contains a list of the line cords that you can use with the Rack PDU:

Power Source

Line cord rating

Plug type

Line cord

part #

 

 

 

 

 

 

 

100-127 V ac, 30 A, single-phase

127 V, 30 A

NEMA L5-30P

24P6846

 

 

 

 

200-240 V ac, 30 A, single-phase

250 V, 30 A

NEMA L6-30P

24P6847

 

 

 

 

200-240 V ac, 32 A, single-phase

250 V, 32 A

IEC 309-2P + Gnd

24P6848

 

 

 

 

200-240 V ac, 30 A, three-phase

250 V, 30 A

NEMA L21-30P

24P6844

 

 

 

 

380-415 V ac, 32 A, three-phase

415 V, 32 A

IEC 309-3P + N + Gnd

24P6845

 

 

 

 

Power cables

The Rack PDU comes with three power cables, that you use to connect to other M/PDU family devices, as listed in the following table:

NetBAY Power Distribution Units 165

Image 173
Contents IBM Page IBM Page Related publications About this supplementFor information about See publication Contents Related service information General checkout IBM PC Server/Enterprise rack enclosuresPower checkout Powering off the rack Hardware Maintenance Manual IBM PC Server/Enterprise Racks Locations FeaturesIBM PC Server expansion rack models Server selector unit Server selector consoleConnections Power distribution unitCooling fan Remove the power distribution unit from the cabinetSingle latch rail tray Sliding traysDual latch rail tray Sliding railsKeyboard tray Parts listing Type 9306 19-inch Models 9QS, 9TS and 9QX, 9TX FRU FRU Rack Enclosure Kits Type Miscellaneous Parts Kit 07H0057 This parts listing is for Models 4QS and 4QX Parts listing Type 9306 24-inch Models 4QS, 4QXNew Zealand 14F1558 South America, India 14F1557 Denmark Rack Enclosure Kits 24-inch Type Hardware Maintenance Manual IBM PC Server/Enterprise Racks Side panel Type 9306 ModelSelector switch in monitor compartment Selector switch locationsSelector switch between side panels Tiered switch configuration Selector switch cable connectionsSingle selector switch Selector switch environmentPower Distribution vertical installation Blank bezel Fixed shelf Keyboard tray Removing the existing flat panel monitor stand Installing a flat panel monitor rack mount kitRemoving the cable cover, hinge cover, and stand cover Removing the existing monitor stand from the monitor Installing the new monitor standInstalling the hinges on the flat panel monitor Installing the flat panel monitor in the keyboard tray Storing the power supply and routing cables Starting the system Configuring the selector switchSwitching among servers Type of Symbol Meaning Advanced selector switch functionsScanning the servers Displaying version information and device settingsSetting a scan pattern Saving Hardware ConfigurationResetting the mouse and keyboard Assigning Unique Names to Servers Magic Centralofc SALES-C SALES-B SALES-A Downtown Foreign Changing menu attributesHardware Maintenance Manual IBM PC Server/Enterprise Racks Changing the status flag attributes Setting Effect on Menu or Window Appearance ResolutionAssi ning specific device types Setting Values and Effect on Flag AppearanceResetting the selector switch Making connections under power Parts Listing Type 9306 Model Index Rack Enclosure Type 9306 Model 12J4484 Hardware Maintenance Manual IBM PC Server/Enterprise Racks Side Panel Type 9306 Model 900/910Perforated Doors model Installing the new door on a model 900 rack cabinet Selector switch locations Selector switch between side panels Selector switch cable connections Selector switch environment Power Distribution UnitPower Distribution installation Blank bezel Fixed shelf Keyboard tray Removing the existing flat panel monitor stand Installing a flat panel monitor rack mount kitRemoving the cable cover, hinge cover, and stand cover Installing the new monitor stand Installing the hinges on the flat panel monitor Installing the flat panel monitor in the keyboard tray Storing the power supply and routing cables Starting the system Configuring the selector switchSwitching among servers Advanced selector switch functions Bios Type 9306 Model 900/910 Magic Centralofc SALES-C SALES-B SALES-A Downtown Foreign Type 9306 Model 900/910 F10 Enter Available menu attributes Row Making connections under power Resetting the selector switchParts listing Type 9306 Model 900/910 Index Rack Enclosure Type 9306 Model 900/910 12J4473 Hardware Maintenance Manual IBM PC Server/Enterprise Racks Features Primary Rack Model 42P Extension Rack Model Primary Rack 42S Removing and installing the side panels Removing and installing panelsRemoving the rack side panels Removing and installing the top 6U side panelsRemoving the top 6U side panels from the rack cabinet DoorsTo remove a door Front and rear doors Models 42P, 42X, 4SA, 4SBRemoving a rear door from the rack cabinet Rear door Models 42S, 42ERemoving a front door from the rack cabinet Front door Models 42S, 42ERemoving the top 6U portion of the rack cabinet Removing and installing the top 6U portion of the rackAttaching rack cabinets in a suite Installing the stabilizer bracketTrim piece Threaded standoff Bolt and washer Installing L-channel support rails to rack mounting brackets On the rail marked R, loosen the four screws c2d Loosely insert one M5 screw c1dinto each rail Installing a server Installing a large server Installing a large serverInstalling a small server Installing a small serverTo install a fixed shelf To install a keyboard tray Monitor shelf To install a monitor shelfInstalling a flat panel monitor rack mount kit Removing the cable cover, hinge cover, and stand cover Installing the new monitor stand Installing the hinges on the flat panel monitor Installing the flat panel monitor in the keyboard tray Storing the power supply and routing cables Blank filler panel To install a blank filler panel Parts listing Type 9308 Model 42P Leveling foot wrench All models 05N4927 FRU Hardware Maintenance Manual IBM PC Server/Enterprise Racks NetBAY3 enclosure Foot pads CastersFront cover Rear panel Device side rails Stacking NetBAY3 enclosures NetBAY3 enclosure Hardware Maintenance Manual IBM PC Server/Enterprise Racks Parts Listing NetBAY3 Hardware Maintenance Manual IBM PC Server/Enterprise Racks NetBAY3E enclosure Front cover NetBAY3E enclosure Device side rails Stacking NetBAY3E enclosures Parts listing NetBAY3E Hardware Maintenance Manual IBM PC Server/Enterprise Racks IBM NetBAY console switch 1x4 Console Switch 2x8 Console Switch Tool requirements Installing a console switch in a monitor shelf SpecificationsInstallation overview Monitor shelf Console switch Rear compartment Installing a console switch vertically in a rack Console switch Vertical mounting bracket Hardware Maintenance Manual IBM PC Server/Enterprise Racks Clip Nuts Cage Installing a console switch horizontally in a rack4 5 6 3 Parts listing NetBAY Console Switch Hardware Maintenance Manual IBM PC Server/Enterprise Racks NetBAY rack Power Distribution Unit introduction NetBAY Power Distribution UnitsInstalling devices vertically Installing the Rack PDU on the vertical mounting plate Installing a single device horizontally Installing the mounting brackets for a single device Installing two devices horizontally Installing the mounting brackets for two devices Cabling your PDUs Installing two Rack PDUs and the blank filler panelStatement Cabling instructions for vertical-mount PDUs Connecting and routing the line cordCabling instructions for horizontal-mount PDUs Connecting and routing other power cables to the outletsConnecting and routing the line cord Connecting and routing other power cables to the outlets Circuit breaker Rack PDU specificationsLength Cable rating Plug type Power cablesLine cords NetBAY front-end Power Distribution Unit introductionInstalling a single device vertically Hardware Maintenance Manual IBM PC Server/Enterprise Racks Installing the vertical mounting plate Routing the fixed line cord and power cables Installing two devices verticallyNetBAY Power Distribution Units Installing the Rack PDU on the vertical mounting plate Routing the fixed line cords Rack PDU specifications Line cords Power cablesNetBAY server dual-cord Power Distribution Unit introduction Tool requirements Installing the Rack PDU on the vertical mounting plate Installing a single device horizontally Installing the Rack PDU and blank filler panel Installing two devices horizontally Installing the mounting brackets for two devices Installing the Rack PDUs and the blank filler panel Hardware Maintenance Manual IBM PC Server/Enterprise Racks Connecting and routing the line cor s Cabling instructions for horizontal-mount PDUs Connecting and routing the line cords Connecting and routing other power cables to the outlets Transfer time Power cables Parts listing Power Distribution Units Hardware Maintenance Manual IBM PC Server/Enterprise Racks Safety information Related service informationPerigo Related service information Hardware Maintenance Manual IBM PC Server/Enterprise Racks Related service information Vorsicht Pericolo Hardware Maintenance Manual IBM PC Server/Enterprise Racks Peligro Safety notice multi-lingual translationsSafety inspection guide Handling electrostatic discharge-sensitive devices Grounding requirements Problem determination tipsRelated service information Send us your comments IBM TrademarksHardware Maintenance Manual IBM PC Server/Enterprise Racks Page 0410K2658