Front and rear doors – Models 42P, 42X, 4SA, 4SB

To remove a door:

1.Unlock the door and open it fully.

2. Grasp the door 1 firmly with both hands and lift it upwards until it is fully off of the hinges 2 .

Notes:

1.Reverse this procedure to reinstall front and rear doors.

2.The top hinge pin is longer than the bottom; engage it first when you reinstall doors.

88Hardware Maintenance Manual: IBM PC Server/Enterprise Racks

Image 96
Contents IBM Page IBM Page About this supplement Related publicationsFor information about See publication Contents Related service information IBM PC Server/Enterprise rack enclosures General checkoutPower checkout Powering off the rack Hardware Maintenance Manual IBM PC Server/Enterprise Racks Features IBM PC Server expansion rack modelsLocations Server selector console Server selector unitPower distribution unit ConnectionsRemove the power distribution unit from the cabinet Cooling fanSliding trays Single latch rail traySliding rails Dual latch rail trayKeyboard tray Parts listing Type 9306 19-inch Models 9QS, 9TS and 9QX, 9TX FRU FRU Rack Enclosure Kits Type Miscellaneous Parts Kit 07H0057 Parts listing Type 9306 24-inch Models 4QS, 4QX This parts listing is for Models 4QS and 4QXNew Zealand 14F1558 South America, India 14F1557 Denmark Rack Enclosure Kits 24-inch Type Hardware Maintenance Manual IBM PC Server/Enterprise Racks Type 9306 Model Side panelSelector switch locations Selector switch in monitor compartmentSelector switch between side panels Selector switch cable connections Tiered switch configurationSelector switch environment Single selector switchPower Distribution vertical installation Blank bezel Fixed shelf Keyboard tray Installing a flat panel monitor rack mount kit Removing the existing flat panel monitor standRemoving the cable cover, hinge cover, and stand cover Installing the new monitor stand Removing the existing monitor stand from the monitorInstalling the hinges on the flat panel monitor Installing the flat panel monitor in the keyboard tray Storing the power supply and routing cables Configuring the selector switch Starting the systemSwitching among servers Advanced selector switch functions Type of Symbol MeaningDisplaying version information and device settings Scanning the serversSaving Hardware Configuration Resetting the mouse and keyboardSetting a scan pattern Assigning Unique Names to Servers Changing menu attributes Magic Centralofc SALES-C SALES-B SALES-A Downtown ForeignHardware Maintenance Manual IBM PC Server/Enterprise Racks Setting Effect on Menu or Window Appearance Resolution Changing the status flag attributesSetting Values and Effect on Flag Appearance Assi ning specific device typesResetting the selector switch Making connections under power Parts Listing Type 9306 Model Index Rack Enclosure Type 9306 Model 12J4484 Hardware Maintenance Manual IBM PC Server/Enterprise Racks Type 9306 Model 900/910 Side PanelPerforated Doors model Installing the new door on a model 900 rack cabinet Selector switch locations Selector switch between side panels Selector switch cable connections Power Distribution Unit Selector switch environmentPower Distribution installation Blank bezel Fixed shelf Keyboard tray Installing a flat panel monitor rack mount kit Removing the existing flat panel monitor standRemoving the cable cover, hinge cover, and stand cover Installing the new monitor stand Installing the hinges on the flat panel monitor Installing the flat panel monitor in the keyboard tray Storing the power supply and routing cables Configuring the selector switch Starting the systemSwitching among servers Advanced selector switch functions Bios Type 9306 Model 900/910 Magic Centralofc SALES-C SALES-B SALES-A Downtown Foreign Type 9306 Model 900/910 F10 Enter Available menu attributes Row Resetting the selector switch Making connections under powerParts listing Type 9306 Model 900/910 Index Rack Enclosure Type 9306 Model 900/910 12J4473 Hardware Maintenance Manual IBM PC Server/Enterprise Racks Features Primary Rack Model 42P Extension Rack Model Primary Rack 42S Removing and installing panels Removing and installing the side panelsRemoving and installing the top 6U side panels Removing the rack side panelsDoors Removing the top 6U side panels from the rack cabinetFront and rear doors Models 42P, 42X, 4SA, 4SB To remove a doorRear door Models 42S, 42E Removing a rear door from the rack cabinetFront door Models 42S, 42E Removing a front door from the rack cabinetRemoving and installing the top 6U portion of the rack Removing the top 6U portion of the rack cabinetInstalling the stabilizer bracket Attaching rack cabinets in a suiteTrim piece Threaded standoff Bolt and washer Installing L-channel support rails to rack mounting brackets On the rail marked R, loosen the four screws c2d Loosely insert one M5 screw c1dinto each rail Installing a server Installing a large server Installing a large serverInstalling a small server Installing a small serverTo install a fixed shelf To install a keyboard tray To install a monitor shelf Monitor shelfInstalling a flat panel monitor rack mount kit Removing the cable cover, hinge cover, and stand cover Installing the new monitor stand Installing the hinges on the flat panel monitor Installing the flat panel monitor in the keyboard tray Storing the power supply and routing cables Blank filler panel To install a blank filler panel Parts listing Type 9308 Model 42P Leveling foot wrench All models 05N4927 FRU Hardware Maintenance Manual IBM PC Server/Enterprise Racks NetBAY3 enclosure Casters Foot padsFront cover Rear panel Device side rails Stacking NetBAY3 enclosures NetBAY3 enclosure Hardware Maintenance Manual IBM PC Server/Enterprise Racks Parts Listing NetBAY3 Hardware Maintenance Manual IBM PC Server/Enterprise Racks NetBAY3E enclosure Front cover NetBAY3E enclosure Device side rails Stacking NetBAY3E enclosures Parts listing NetBAY3E Hardware Maintenance Manual IBM PC Server/Enterprise Racks IBM NetBAY console switch 1x4 Console Switch 2x8 Console Switch Tool requirements Specifications Installation overviewInstalling a console switch in a monitor shelf Monitor shelf Console switch Rear compartment Installing a console switch vertically in a rack Console switch Vertical mounting bracket Hardware Maintenance Manual IBM PC Server/Enterprise Racks Installing a console switch horizontally in a rack Clip Nuts Cage4 5 6 3 Parts listing NetBAY Console Switch Hardware Maintenance Manual IBM PC Server/Enterprise Racks NetBAY Power Distribution Units NetBAY rack Power Distribution Unit introductionInstalling devices vertically Installing the Rack PDU on the vertical mounting plate Installing a single device horizontally Installing the mounting brackets for a single device Installing two devices horizontally Installing the mounting brackets for two devices Installing two Rack PDUs and the blank filler panel Cabling your PDUsStatement Connecting and routing the line cord Cabling instructions for vertical-mount PDUsConnecting and routing other power cables to the outlets Cabling instructions for horizontal-mount PDUsConnecting and routing the line cord Connecting and routing other power cables to the outlets Rack PDU specifications Circuit breakerPower cables Length Cable rating Plug typeNetBAY front-end Power Distribution Unit introduction Line cordsInstalling a single device vertically Hardware Maintenance Manual IBM PC Server/Enterprise Racks Installing the vertical mounting plate Installing two devices vertically Routing the fixed line cord and power cablesNetBAY Power Distribution Units Installing the Rack PDU on the vertical mounting plate Routing the fixed line cords Rack PDU specifications Power cables Line cordsNetBAY server dual-cord Power Distribution Unit introduction Tool requirements Installing the Rack PDU on the vertical mounting plate Installing a single device horizontally Installing the Rack PDU and blank filler panel Installing two devices horizontally Installing the mounting brackets for two devices Installing the Rack PDUs and the blank filler panel Hardware Maintenance Manual IBM PC Server/Enterprise Racks Connecting and routing the line cor s Cabling instructions for horizontal-mount PDUs Connecting and routing the line cords Connecting and routing other power cables to the outlets Transfer time Power cables Parts listing Power Distribution Units Hardware Maintenance Manual IBM PC Server/Enterprise Racks Related service information Safety informationPerigo Related service information Hardware Maintenance Manual IBM PC Server/Enterprise Racks Related service information Vorsicht Pericolo Hardware Maintenance Manual IBM PC Server/Enterprise Racks Safety notice multi-lingual translations PeligroSafety inspection guide Handling electrostatic discharge-sensitive devices Problem determination tips Grounding requirementsRelated service information Send us your comments Trademarks IBMHardware Maintenance Manual IBM PC Server/Enterprise Racks Page 0410K2658