IBM 1116 manual Default

Page 87

This light sequence in

 

advanced troubleshooting

 

mode:

Corresponds to this setting:

 

 

 

 

 

 

 

 

 

 

 

For entry and standard models, Parallel Mode 1 is set to On, the factory

 

 

 

 

 

default.

 

 

 

 

 

This setting disables the pull-up resistors on the parallel port signals. It is

 

 

 

 

 

useful for computers that have open collector outputs on the parallel port

 

 

 

 

 

signals.

 

 

 

 

 

• Press the operator panel button with a double button press to scroll to

 

 

 

 

 

the next menu item, Parallel Mode 2.

 

 

 

 

 

• Turn off the printer to exit the advanced troubleshooting mode.

For entry and standard models, Parallel Mode 2 is set to On, the factory default.

This setting determines if the parallel port data is sampled on the leading or trailing edge of strobe. If Parallel Mode 2 is set to On, the parallel port data is sampled on the leading edge of strobe. The parallel port data is sampled on the trailing edge of strobe if Parallel Mode 2 is set to Off.

• Press the operator panel button with a brief button press to scroll through the settings (On, Off). To turn off this setting, press the operator panel button with a long button press to select and save the Off setting. As the setting is saved, all operator panel lights remain on for approximately 2 seconds

Press the operator panel button with a double button press to scroll to the next menu item, Parallel Strobe Adjust.

Turn off the printer to exit the advanced troubleshooting mode.

83

Argecy Computer Corporation 248-324-1800

Image 87
Contents User’s Reference Argecy Computer Corporation User’s Reference Argecy Computer Corporation Table of contents Loading labels Iii Argecy Computer Corporation About your printer Printer overviewUse this feature When you want to Operator panel has 6 lights and 1 operator panel button Using the operator panelArgecy Computer Corporation From a Macintosh computer Canceling a print jobFrom the printer operator panel From a Windows computerPrinting from a Windows environment Setting up a print jobArgecy Computer Corporation Printing from a Macintosh computer Choosing the right print media Media types and sizes Media Size Weight CapacityPrinter media sources Argecy Computer Corporation Tray Loading paperArgecy Computer Corporation Manual feed Argecy Computer Corporation Optional tray Corner bucklers Argecy Computer Corporation Loading transparencies Argecy Computer Corporation Manual feed Argecy Computer Corporation Loading envelopes Manual feed Argecy Computer Corporation Loading labels Argecy Computer Corporation Manual feed Argecy Computer Corporation Loading card stock Manual feed Argecy Computer Corporation Printing on both sides of the paper Short Edge means the pages are bound along the short edge Conserving supplies Removing the old print cartridge Replacing the print cartridgeInstalling the new print cartridge Fuser Clearing jams Remove the print cartridge it may be warm Argecy Computer Corporation Argecy Computer Corporation Reinstall the tray and resume printing Understandinglightsthe operator panel Argecy Computer Corporation Secondary error code Toner low Argecy Computer Corporation What this light sequence means Argecy Computer Corporation Argecy Computer Corporation Printer is flushing corrupted print data Argecy Computer Corporation Argecy Computer Corporation Print the other side of your duplex print job Argecy Computer Corporation Argecy Computer Corporation Printer flash memory is full Argecy Computer Corporation Printer memory is full Printer has received a page that is too complex to print Toner is low and the toner alarm is set to on Argecy Computer Corporation Argecy Computer Corporation Printer has a service error and printing has stopped Problem What to do Solving print quality problemsCartridge Printer or the computer Loading Paper From the special function menu, select Hex Trace mode to Using the special function menu Resetting user defaultsEnter the special function menu Restoring factory defaultsUsing Hex Trace mode Advanced troubleshooting mode Using print quality test pagesAdvanced troubleshooting Argecy Computer Corporation Factory default Argecy Computer Corporation Default Argecy Computer Corporation USB NPA Mode is set to Auto, the factory default Auto CRLF/LFCR is set to Off, the factory default Setting up the network printer Connect the hardware Print a network setupEnvironments we support Requirements Configure and printPrint Server TCP/IP Setup Utility Set the IP address, netmask and gatewayTroubleshooting InstallationStatic ARP entry and telnet Print to a queue on a Windows NT server Set up to printSet up IP printing on Windows NT 4.0/2000 Part 1 Install printer drivers and TCP/IP network supportPart 2 Create a Network Port Set up IP printing on Windows 95/98/Me Part 2 Create a Network Port Part 1 Installing printer drivers and TCP/IP network support Install a shared printer on a Windows NT 4.0/2000 serverPart 3 Sharing the printer on the network Part 2 Creating a Network PortSetting up clients point and print Install a shared printer on network clientsSetting up clients peer-to-peer Novell NetWare Nprinter in IntraNetWare NDS Choosing NPRINTER/RPRINTER or PserverAdvantages of using Pserver in NDS Disadvantage of using Pserver in NDSPserver in IntraNetWare NDS Rprinter vs. Pserver in NetWare Rprinter in NetWarePserver in NetWare Creating a desktop printer icon Finding the default AppleTalk nameAppleTalk Queue-based printingChanging the printer name Changing the zoneQuickDraw GX environment Updating printer hardwareLaserWriter 8 environment prior to LaserWriter LaserWriter 8 environment LaserWriter 8.4.1 and laterNormal conditions Print server light patternsError conditions Trademarks Edition noticeSafety information Industry Canada compliance statement Electronic emission noticesJapanese Vcci notice United Kingdom Telecommunications Act German acoustics statementAvis de conformité aux normes d’Industrie Canada European Community EC directives conformityLaser notice Dhcp Index113 114 Argecy Computer Corporation Part Number 53P9570