Using the Summary Tab

Use the Summary tab to view the status of the power, fans, and temperature sensors simultaneously. (See Figure 5-8.)

The Summary tab has the following fields:

Power

A green check indicates that at least one power source is connected and functioning properly.

A red check indicates that the power supply AC is disconnected.

Fans

A green check indicates that at least one fan is present and functions properly.

A red check indicates a fan failure.

Sensors

A green check indicates that the system temperature is at an acceptable level.

A red check indicates a high-temperature warning.

Using the Power Supplies Tab

Use the Power Supplies tab to view the operating status of the power supplies. (See Figure 5-9.)

Figure 5-9 Health Status Power Supplies Window

Using the Fans Tab

Use the Fans tab to view the operating status of the fans. (See Figure 5-10.)

Figure 5-10 Health Status Fans Window

Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide

 

OL-10853-01

5-5

 

 

 

Image 57
Contents Text Part Number OL-10853-01 Corporate HeadquartersPage Iii N T E N T SLatency Managing the Switch Chassis and Management Interface A-1 Audience PrefaceOrganization Chapter Title DescriptionConventions Convention DescriptionViii Warnung Wichtige Sicherheitshinweise Bewaar Deze InstructiesAviso Instruções Importantes DE Segurança Avvertenza Importanti Istruzioni Sulla SicurezzaPage Xii GEM Disse AnvisningerXiii Obtaining Documentation Related DocumentationCisco.com XivDocumentation Feedback You can access international Cisco websites at this URLCisco Product Security Overview Product Documentation DVD Ordering DocumentationReporting Security Problems in Cisco Products Product Alerts and Field NoticesXvi Obtaining Technical Assistance Cisco Technical Support & Documentation WebsiteXvii Definitions of Service Request Severity Submitting a Service RequestObtaining Additional Publications and Information XviiiXix OL-10853-01 Product Overview Introduction to SwitchesSwitch Components Switch ConnectorsPower Supply Bay System FeaturesPower Supply Module LEDsHigh Availability ScalabilityAdministrative Features OL-10853-01 Preparation for Installation SafetySite Requirements Temperature HumidityAltitude Dust and Particles CorrosionElectromagnetic and Radio Frequency Interference Power Source Interruptions Shock and VibrationPreventing Electrostatic Discharge Damage Air Flow Power RequirementsTask No Planning Activity Verified By Time Date Site Preparation ChecklistInstalling the Switches Pre-installation Instructions Rack-Mounting the Switch Rack-Mounting the SwitchesPlace the switch on a secure, clean surface RequirementsInstalling the Switch with One Person Holding Bracket Inside of Rack Installing the Switch with Two People Configuring Basic Connectivity Obtaining an IP AddressFollowing sections appear in this section Obtaining a Static IP Address for Ethernet Management Enter the configure command to enter the configuration mode Enter the enable commandSFS-7000Dconfig#interface mgmt-ethernet SFS-7000Dconfig#address-option staticPowering Up the Chassis Connecting the 10/100 Ethernet Management PortSave the configuration to preserve it between reboots SFS-7000D#copy running-config startup-configConnecting Network Devices To connect InfiniBand devices, follow these steps Connecting InfiniBand Devices13 InfiniBand Cable with Pinch Connector Managing the System Connecting Ethernet Management DevicesInstalling the Switches Managing the System OL-10853-01 Power Supply Modules Installing Field Replaceable UnitsLocating the Power Supply Unit Failed Power Supply ModulesRemoving a Filler Panel from the Switch Installing a Power Supply ModuleRemoving the Power Supply from the Switch Pull the unit from the bay Removing Power Supply ModulesLEDs Managing the SwitchChassis Status LEDs Color Indication Bi-color chassis status LED Power Supply LEDs InfiniBand Port LEDs2describes the InfiniBand Port LED operation Managing the System with Element Manager Power Supply and Fan LEDs LocationUsing the Summary Tab Using the Power Supplies TabUsing the Fans Tab Displaying Power Supply Information Using the Sensors TabSFS-7000P#show power-supply Displaying System InformationDisplaying Sensor Information Displaying Fan InformationOL-10853-01 About Diagnostic Tests Hardware Diagnostic TestsLED Tests Self-TestsRunning Card Self-Test SFS-7000P#show diagnostic cardRunning Chassis Self-Test SFS-7000Pconfig#diag chassis test standardSFS-7000P-1#show diag post Running Fan Self-TestSFS-7000P#show diagnostic fan Enter the diag fan id commandReboot the chassis when the self-test is complete Running Power Supply TestsDiag Fru-error Diag FanRunning a LED Test on the Power Supply Running a Self-Test on a Power SupplyStart the test Displaying Hardware Errors EnableMore sysloghwiflog Power supply DC fail error Error Number DescriptionPower supply fan fail error Power supply I2C communication errorOL-10853-01 Specifications and Compliance Certifications SpecificationChassis and Management Interface Category Specification Electrical SpecificationsAcronym Expansion Acronyms and AbbreviationsAppendix B Acronyms and Abbreviations IN-5 D EIN-6 IN-7 Nonvolatile memoryIN-8 IN-9 IN-10