Cisco Systems OL-6157-01 manual Symptom Possible Cause Resolution, B-5 through

Page 50

Chapter 3 Troubleshooting

Diagnosing Common Problems

Table 3-1 Common Connectivity Problems and Their Solutions

Symptom

Possible Cause

Resolution

 

 

 

No connectivity to 10/100 ports

Incorrect or bad cable.

 

or 10/100/1000 port.

 

 

 

These are the results of no link at

 

 

both ends:

 

 

• Cable not properly installed

• Remove and reconnect cable

 

 

to switch and PC. Wait 30

 

between switch and PC.

 

seconds for port status LED

 

 

 

 

on switch to turn green.

 

• A crossover cable was used

• To identify a crossover

 

when a straight-through was

cable, see Figure B-12 on

 

required, or vice-versa.

page B-9.

 

• The cable is wired

• Verify that the cable is wired

 

incorrectly.

correctly. See Figure B-6 on

 

 

page B-5through

 

 

Figure B-9 on page B-6for

 

 

the correct pinouts of 10/100

 

 

cables. For the proper

 

 

application of crossover and

 

 

straight-through cables, see

 

 

the “Cable and Adapter

 

 

Specifications” section on

 

 

page B-5.

 

 

• Replace it with a tested good

 

 

cable.

 

• STP is checking for possible

• Wait 30 seconds for port

 

network loops.

status LED to turn green.

 

 

 

No connectivity to

An SFP module was installed in

Remove the SFP module, and

100BASE-FX port.

the switch at power on.

reboot the switch.

 

Note The SFP module slots

Note See the “Connecting to

 

and the 100BASE-FX

an SFP Module” section

 

port cannot both be used

on page 2-12and the

 

at the same time. If an

Cisco Small

 

SFP module is installed

Form-Factor Pluggable

 

when the switch is

Modules Installation

 

powered on, the

Notes (order number

 

100BASE-FX port is

DOC-7815160=) for

 

disabled.

procedures on removing

 

 

an SFP module.

 

 

 

Catalyst 2940 Switch Hardware Installation Guide

3-2

OL-6157-01

 

 

Image 50
Contents Catalyst 2940 Switch Hardware Installation Guide Corporate HeadquartersCatalyst 2940 Switch Hardware Installation Guide N T E N T S Installation Accessing the CLI Through the Console Port D-2 Contents Catalyst 2940 Hardware Installation Guide Conventions AudiencePurpose Bewaar Deze Instructies Warnung Wichtige SicherheitshinweiseAvvertenza Importanti Istruzioni Sulla Sicurezza Aviso Instruções Importantes DE SegurançaOL-6157-01 GEM Disse Anvisninger Xii Related Publications Documentation CD-ROM Obtaining DocumentationCisco.com Ordering DocumentationCisco TAC Website Opening a TAC Case Obtaining Technical AssistanceDocumentation Feedback Obtaining Additional Publications and Information TAC Case Priority DefinitionsXvii Xviii Setting up the Switch FeaturesFront-Panel Description 10/100 Ethernet ports 100BASE-FX port SFP module slot10/100/1000 Port Port Numbering10/100 Ports Port or Slot type Catalyst 2940-8TT-S Catalyst 2940-8TF-SType Cisco Part Number 100BASE-FX PortSFP Module Slot 62.5/125 micron 50/125 micron Micron Single-mode SFP ModulesMicron Cable Guard LEDsMode LED Port Mode Description Color System StatusPort Mode Color Meaning Power Connector Rear-Panel DescriptionConsole Port Security SlotsManagement Options OL-6157-01 Installation Preparing for InstallationChapter Installation Guidelines Verifying Package ContentsVerifying Switch Operation Installing the Switch on a Desk With Mounting Screws Installing the SwitchInstalling the Switch on a Desk Without Mounting Screws Installing the Mounting Screws on Top of a Desk Installing the Switch Under a Desk Mounting the Switch on Top of a DeskInstalling the Mounting Screws Under a Desk Installing the Switch on a Wall Mounting the Switch Under a DeskThis Side Switch Screw Slides on this way Connecting to an SFP Module Installing the Switch Magnet MountConnecting to an SFP Module Port Connecting to 10/100 Ports and the 10/100/1000 Port Connecting to a 10/100 PortConnecting to the 100BASE-FX Port 10 Connecting to a 100BASE-FX Port11 Connecting to an SFP Module Port Where to Go Next Chapter Diagnosing Common Problems Understanding Post ResultsSymptom Possible Cause Resolution B-5 throughNo connectivity to SFP Poor performance or excessive System LED is amber OL-6157-01 Environmental Ranges Power RequirementsPhysical Dimensions SFP module Fiber-Port Power Levels 100BASE-FX port Slot1Safety Table A-3 Catalyst 2940 Switch Agency Approvals OL-6157-01 Connectors and Cables Connector SpecificationsFigure B-2 10/100 RJ-45 Pinouts Connecting to 10BASE-T and 100BASE-TX Devices 10/100/1000 PortsFigure B-4 MT-RJ Connector Cable and Adapter Specifications Two Twisted-Pair Cable PinoutsFour Twisted-Pair Cable Pinouts for 10/100 Ports TD+Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports TPOConnecting to a PC Cable and Adapter PinoutsIdentifying a Rollover Cable OL-6157-01 Configuring the Switch with the CLI-Based Setup Program Methods for Accessing the CLIAccessing the CLI Through the Console Port Taking Out What You NeedConnecting to a Power Source Connecting to the Console PortFigure C-3 Connecting a Switch to a PC Starting the Terminal Emulation SoftwareEntering the Initial Configuration Information IP SettingsCompleting the Setup Program These choices appear CLI Numerics IN-2 IN-3 IN-4 IN-5 IN-6