Cisco Systems OL-16447-01 manual Power-Supply Module LEDs, Switch Power-Supply LEDs

Page 19

Chapter 1 Product Overview

Front Panel

Table 1-3

System LED (continued)

 

 

 

Color

 

System Status

 

 

 

Green

 

System is operating normally.

 

 

 

Amber

 

System is receiving power but is not functioning properly.

 

 

 

1. POST = power-on self-test.

Power-Supply Module LEDs

The power-supply module LEDs show whether power-supply modules 1 and 2 are receiving power.

Figure 1-7 Switch Power-Supply LEDs

1

4

2

3

280935

1

AC-power-supply LEDs

3

PSU 2 (power supply 2) LED

 

 

 

 

2

PSU 1 (power supply 1) LED

4

DC-power-supply LEDs

 

 

 

 

The Cisco ME 3400E-24TS-M and the Cisco ME 3400EG-12CS-M have power-supply module LEDs labeled PSU 1 and PSU 2. See Figure 1-7.

Table 1-4

PSU 1 and PSU 2 Power-Supply LEDs

 

 

Color

System Status

 

 

Off

Power-supply module (1 or 2) is either not installed or not producing power.

 

 

Green

Power-supply module (1 or 2) is installed and producing power in an acceptable range.

 

The fans are operating normally.

 

 

Red

Power-supply module (1 or 2) is not producing power in an acceptable range, or a fan has

 

failed.

 

 

Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide

 

OL-16447-01

1-9

 

 

 

Image 19
Contents Text Part Number OL-16447-01 Americas HeadquartersPage N T E N T S Installing the Switch Rack-Mounting Link Status IP Settings C-2 Purpose AudienceViii Related PublicationsObtaining Documentation and Submitting a Service Request OL-16447-01 Switch Models Setting Up the SwitchFront Panel Switch Model DescriptionCisco ME 3400EG-12CS-M Front Panel Alarm Input Port AC- and DC-Power Input ConnectorsSFP Modules Management Port10/100 Fast Ethernet Ports Dual-Purpose PortsPart Number Description SFP Module Patch CableLEDs UNIs, NNIs, and ENIsColor System Status Switch LED PanelsSwitch Power-Supply LEDs Power-Supply Module LEDsEthernet Management Port LED LED Color Meaning Alarm LEDsPort LEDs Dual-Purpose Port LEDsRear Panel Power-supply slot Ground connection11 Cisco ME 3400EG-2CS-A Rear Panel Power Supply FeaturesManagement Options FansNetwork Configurations OL-16447-01 Switch Installation Switch Installation Switch Installation Installation Guidelines Installing the Switch Verifying Switch OperationPowering Off the Switch Rack-Mounting Removing Screws from the SwitchRack-Mounting Brackets Attaching Brackets to the SwitchAttaching Brackets for 19-Inch Racks Attaching Brackets for 19-Inch, 23-Inch, and 24-Inch Racks Attaching Brackets for 23-Inch Racks Attaching Brackets for 24-Inch Racks Attaching Brackets for Etsi Racks Mounting in a Rack Mounting in a RackAttaching Brackets for Wall-Mounting Wall-MountingMounting the Switch on a Wall Cisco ME 3400EG-12CS-M Cisco ME 3400E-24TS-M Cisco ME 3400EG-2CS-A Installing SFP Modules Installing and Removing SFP ModulesTable- or Shelf-Mounting 16 SFP Module with a Bale-Clasp Latch Removing SFP Modules Inserting and Removing the SFP Module Patch CableRemoving the SFP Module Patch Cable Connecting to the 10/100 and 10/100/1000 Ports21 Connecting to an Ethernet Port 22 Connecting to a Fiber-Optic SFP Module Port Connecting to Fiber-Optic SFP Modules23 Connecting to a 1000BASE-T SFP Module Connecting to 1000BASE-T SFP ModulesWhere to Go Next Connecting to Dual-Purpose PortsProduct Overview Power-Supply Module DescriptionModel number Description PSU OK LED Handle-Side DescriptionPSU OK DC-Power-Supply Module Power-Supply Module InstallationConnector-Side Description AC-Power-Supply ModuleTools and Equipment Installation GuidelinesAC-1 PSU-1 AC-2 PSU-2 Installing an AC-Power-Supply ModuleAC-Power Supply and Power-Cord Retainer in a Switch Removing AC-Power-Supply ModulesInstalling a DC-Power-Supply Module Grounding the Switch Preparing for InstallationRemove the ground screw from the switch rear panel 12 Attaching the Ground Lug and Wire Assembly Installing the DC-Power-Supply Module in the SwitchStatement Wiring the DC-Input Power Source15 Terminal Block Plug 18 Inserting Wires in the Terminal Block Plug 21 Inserting the Terminal Block in the Block Header 22 DC-Power Terminal Block With Two Feeds Removing the DC-Power-Supply ModulePower Supply Settings OL-16447-01 Switch Post Results Diagnosing ProblemsEthernet and Fiber Cables Switch LEDsSwitch Connections Bad or Damaged CableSpanning Tree Loops SFP Module Port IssuesPort and Interface Settings Ping the End DeviceAutonegotiation and NICs Clearing the Switch IP Address and ConfigurationSwitch Performance Speed, Duplex, and AutonegotiationSerial Number Location on the Cisco ME 3400E-24TS-M Finding the Switch Serial NumberOL-16447-01 SFP Module 32 to 131F 0 to 55C 32 to 140F 0 to 60C Environmental Ranges32 to 149F 0 to 65C With 1 Power-Supply With 2 Power-Supply SFP Module Modules32 to 149 F 0 to 65C AC-Power Requirements Physical DimensionsDC-Power Requirements Physical Dimensions Power Specifications Physical SpecificationsPower Specifications OL-16447-01 10/100 Connector SpecificationsFigure B-2 Fiber-Optic SFP Module LC Connector SFP Module ConnectorsFigure B-3 10/100/1000 Port Pinouts 10/100 Ethernet Management PortBandwidth SFP Module Wavelength nanometers Fiber Type Cables and AdaptersSFP Module Cables Core Modal1000BASE-SX TP3 Cable PinoutsDSR DTR CTS RTS Console Port Adapter PinoutsSwitch Console RJ-45-to-DB-25 Port DTE Starting the Terminal-Emulation Software Accessing the CLI Through the Console PortIP Settings Entering the Initial Configuration InformationCompleting the Setup Program Enter an enable secret password, and press Return These choices appear Numerics IN-2 IN-3 IN-4 IN-5 IN-6