Installation Procedures
Installation Procedures
Use this section if you are installing the FC_MR-4 card for the first time. After you become familiar with ONS 15454 SONET/SDH card installation and boot up, use this section as a reference. For information about fiber optic cable installation, see the Cisco ONS 15454 SDH Reference Manual, the Cisco ONS 15454 SDH Procedure Guide, the Cisco ONS 15454 Reference Manual, or the Cisco ONS 15454 Procedure Guide.
Warning Hazardous voltage or energy may be present on the backplane when the system is operating. Use caution when servicing.
Caution Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454 SONET/SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf assembly and ensure the shelf assembly is properly grounded.
FC_MR-4 cards have electrical plugs that plug into electrical connectors on the shelf assembly backplane. When the ejectors are fully closed, the card plugs into the shelf assembly backplane. Figure 2 shows general card installation. The example shows the installation in an ONS 15454. The procedure in an ONS 15454 SDH is identical.
Figure 2 Installing a card in an ONS 15454
Installing Cisco ONS 15454 SONET/SDH FC_MR-4 Cards