Cisco Systems 15454-ML-4FC= Installation Procedures, Installing a card in an ONS

Page 4

Installation Procedures

Installation Procedures

Use this section if you are installing the FC_MR-4 card for the first time. After you become familiar with ONS 15454 SONET/SDH card installation and boot up, use this section as a reference. For information about fiber optic cable installation, see the Cisco ONS 15454 SDH Reference Manual, the Cisco ONS 15454 SDH Procedure Guide, the Cisco ONS 15454 Reference Manual, or the Cisco ONS 15454 Procedure Guide.

Warning Hazardous voltage or energy may be present on the backplane when the system is operating. Use caution when servicing.

Caution Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454 SONET/SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf assembly and ensure the shelf assembly is properly grounded.

FC_MR-4 cards have electrical plugs that plug into electrical connectors on the shelf assembly backplane. When the ejectors are fully closed, the card plugs into the shelf assembly backplane. Figure 2 shows general card installation. The example shows the installation in an ONS 15454. The procedure in an ONS 15454 SDH is identical.

Figure 2 Installing a card in an ONS 15454

Installing Cisco ONS 15454 SONET/SDH FC_MR-4 Cards

4

78-16233-01

 

 

Image 4
Contents Installing Cisco ONS 15454 SONET/SDH FCMR-4 Cards FCMR-4 Card Description1shows the FCMR-4 faceplate and block diagram FCMR-4 Port-Level Indicators FCMR-4 Card-Level IndicatorsFCMR-4 Card Specifications Installation Procedures Installing a card in an ONSProcedure Install the FCMR-4 Card Related DocumentationObtaining Documentation Documentation FeedbackCisco.com Ordering DocumentationCisco TAC Website Obtaining Technical AssistanceOpening a TAC Case Obtaining Additional Publications and Information TAC Case Priority DefinitionsObtaining Additional Publications and Information