Cisco Systems VG224 Wall-Mounting the Chassis, Attaching the Brackets for Wall-Mounting

Page 9

Chapter 3 Installing the Cisco VG224 Voice Gateway

Wall-Mounting the Chassis

Wall-Mounting the Chassis

The following warning applies only when the unit is wall-mounted:

Warning This unit is intended to be mounted on a wall. Please read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system. Statement 248

Caution You can wall-mount the unit with either the right or left side facing up; however, the front and rear panels must be vertical.

Note For information about obtaining the chassis guard, refer to field notice number 28655, VG224 Chassis Guard - Safety Regulation, at http://www-tac.cisco.com/Support_Library/field_alerts/fn28655.html.

To wall-mount the chassis, follow this procedure:

Step 1 Attach the short leg of one bracket to the chassis, as shown in Figure 3-7, using two 6-32 x 1/4 slotted hex screws (provided). Be sure to use a plastic washer (provided) with each screw; the narrow end of the washer must fit into the bracket slot, facing the chassis.

Caution Be sure to use the correct screws and plastic washers for this mounting option. (See Table 3-1 on page 3-6.)

Figure 3-7 Attaching the Brackets for Wall-Mounting

88843

Step 2 Attach the second bracket to the opposite side of the chassis.

Step 3 Attach the router to the wall using the brackets previously attached and attachment hardware that you provide as follows:

You can install a starter screw in the wall, and hook the bracket keyhole over the screw. This holds the unit in place for easy installation of the attachment screws.

Attach both brackets to the wall.

Cisco VG224 Voice Gateway Hardware Installation Guide

 

OL-5006-04

3-9

 

 

 

Image 9
Contents Installing the Cisco VG224 Voice Gateway Maintaining Safety with Electricity Safety RecommendationsGeneral Safety Practices Safety TipsPreventing Electrostatic Discharge Damage Site LogInstallation Checklist Keeping Track-ChecklistUnpacking and Inspection Mounting Tools and Equipment Rack-Mounting the Chassis Mounting Screws Rack-mounting Wall-mounting Attaching the Brackets 19-Inch Rack Installation-Front Panel ForwardStatement Installing the Cisco VG224 Voice Gateway in a RackAttaching the Brackets for Wall-Mounting Wall-Mounting the Chassis8shows the orientation required for installation Installing the Ground Connection Bench-Top InstallationCrimping a Ground Lug onto the Ground Wire 10 NEBS-Compliant Chassis Ground Connection Using Ground Lug Connecting Cables 120 VAC, 15A 240 VAC, 10A international StatementNebs Tests Results Connected To Cable LAN and Power CablesConnecting the Console Port to a PC or an Ascii Terminal Connecting the Input PowerConnecting the Auxiliary Port to a Modem Color or Type Connected To Cable Voice Cables14 Analog Voice Connection Connecting to a Modem Ports, Connectors, and PinoutsConnecting to a Remote PC Cisco VG224 Port Port Color Connector/Cable Interface ToConnecting Backup Power Connecting to a Remote Ascii TerminalConnecting a Backup Battery to a DC-Powered Cisco VG224 Pin Number Descriptions 15 Connecting a Battery Backup to a DC-Powered Cisco VG224UPS Connecting a UPS to an AC-Powered Cisco VG224OL-5006-04