Chapter 1 Product Overview
Multigigabit Crossbar Switch Fabric
Switch Fabric Switching Capacity and Router Type
The Cisco 12006 Router is based on a
Cisco 12006 Router can be identified by the Cisco identification labels on the switch fabric cards (SFCs and CSCs): The CSC is labeled
The Cisco 12406 Router is based on a
Note You cannot mix
Switch Fabric Redundancy
Equipping the router with two CSCs provides data path, scheduler, and reference clock redundancy. The interfaces between the line cards and the switch fabric are monitored constantly. If the router detects a loss of synchronization (LOS), it automatically activates the data paths of the redundant CSC, and data flows across the redundant path. The switch to the redundant CSC occurs within 0.5 second, with little or no loss of data.
| Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide |