Cisco Systems 12406 series, 12006 series manual LED Label Color Function

Page 46

Chapter 1 Product Overview

Power Subsystems

Three LEDs on the faceplate to provide status information. Table 1-7summarizes the function of these indicators.

Table 1-7

DC-input PEM LED Indicators

 

 

 

 

LED Label

 

Color

Function

 

 

 

 

OUTPUT OK

 

Green

PEM is operating normally in a powered-on

 

 

 

condition.

 

 

 

 

INPUT OK

 

Green

DC power is present at the PEM input and

 

 

 

within the specified limits.

 

 

 

 

MISWIRE

 

Amber

Indicates input is wired backward at the PDU

 

 

 

input.

 

 

 

 

Each PEM weighs 10.5 pounds (4.76 kg), and can deliver up to 1400 W at –48 VDC.

Only a DC power source that complies with the safety extra-low voltage (SELV) requirements in UL1950, CSA 950, EN 60950, and IEC950 can be connected to a PEM.

Cisco 12006 and Cisco 12406 routers with a DC PDU and DC-input power entry modules (PEMs) require an external DC circuit breaker for each DC power source:

Original series Cisco 12006 and Cisco 12406 router input power shall not draw more than 45A max. @ 40.5VDC form each DC power source.

Enhanced series Cisco 12006 and Cisco 12406 router input power shall not draw more than 60A max. @ 40.5VDC from each DC power source.

This circuit breaker should protect against short-circuit and overcurrent faults in accordance with United States National Electrical Code NFPA 70 (United States), Canadian Electrical Code, part I, CSA C22.1 (Canada), and IEC 364 (other countries).

Note Cisco Systems recommends that you install an uninterruptable power source (UPS) as a safeguard against power loss.

 

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

1-46

OL-11497-03

Image 46
Contents Product Overview IntroductionProduct Description Cisco 12006 and Cisco 12406 router Front View Product Overview Product Description Product Overview Product Description Cisco 12006 and Cisco 12406 router Rear View Chassis Physical and Functional DescriptionRP and Line Card Slots Alarm Card Slots Switch Fabric Card SlotsChassis Backplane Power CoolingMultigigabit Crossbar Switch Fabric Switch Fabric Card TypesNonredundant and Redundant System Configurations Switch Fabric Switching Capacity and Router Type Switch Fabric RedundancyPower-Up/Down Control Maintenance BusDevice Discovery Environmental Monitoring and Alarms DiagnosticsCode Download Route Processors Route Processor FunctionsRoute Processor Types Gigabit Route ProcessorProduct Overview Route Processors GRP Layout GRP Memory Components Type Size Quantity Description LocationSram Reset AUX Coll RX Link MII System Status LEDsSoft Reset Switch GRP Alphanumeric LED Displays Partial FaceplatePcmcia Slots Asynchronous Serial PortsEthernet Port Performance Route Processor Performance Route Processor Front ViewProduct Overview Route Processors PRP Horizontal Orientation PRP Memory Components SdramSdram Flash Disk Size Product Number Soft Reset Switch Flash Disk Slots Ethernet PortsLine Cards 10 Sample Line Cards Alarm Cards AlarmClock and Scheduler Card and Switch Fabric Card Status Alarm Output FunctionAlarm Card Status Power Source Monitoring Power SubsystemsAlarm Relay Contact Connector AC Power Subsystem AC PDU12 AC Power Distribution Unit AC-Input Power Supply 13 AC-Input Power SupplyProduct Overview Power Subsystems DC Power Subsystem LED Label Function State Description14 DC Power Distribution Unit Power a DC-Input Power Entry Module16 DC-Input Power Entry Module LED Label Color Function Power Distribution Blower ModuleTop view Air Filters 18 Air Filter LocationsCable-Management System 19 Chassis Cable-Management System Technical Specifications Field-Replaceable Units