Chapter 1 Product Overview
Blower Module
Power Distribution
The router chassis backplane distributes
All cards have multiple
+2.5 VDC, +3.3 VDC, +5 VDC, and other voltages as required by the line card. The
Power for the blower module is supplied directly from the backplane through a connector in the PDU that passes DC voltage from the backplane to the blower module. An blower module controller card in the blower module converts
Caution To ensure that the chassis configuration complies with the required power budgets, use the
Blower Module
Cisco 12006 and Cisco 12406 routers are equipped with a blower module to distribute air within the chassis. The blower module is located on the rear of the chassis. (See Figure
Caution Exhaust from other equipment vented directly into the router air inlet may cause overheating.
The front, back, and sides of the router must remain unobstructed to ensure adequate air flow and prevent overheating inside the chassis. Allow sufficient air flow by maintaining 6 inches (15.24 cm) of clearance at both the inlet and exhaust openings on the chassis.
|
| Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide |
|
|
|
|
| ||
|
|
| ||
|
|
|