Cisco Systems 12006 series, 12406 series manual Air Filters, Air Filter Locations

Page 49

Chapter 1 Product Overview

Blower Module

OK—Left LED; Green. When on, this LED indicates that the blower module is operating normally. This LED should come on as soon as the blower module is installed and receives power from the backplane connector.

FAIL—Right LED; Red. The red LED should remain off during normal operation. If the red LED is on, the system has detected a fan failure or other fault in the blower module. Replace the existing blower module with a spare.

Air Filters

Cisco 12006 and Cisco 12406 routers are equipped with two user-serviceable air filters. (See Figure 1-18.)

Figure 1-18 Air Filter Locations

AUX

CISCO 12000 SERIES

GIGABIT SWITCH ROUTER

57678

 

 

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

 

 

 

 

 

 

OL-11497-03

 

 

1-49

 

 

 

Image 49
Contents Introduction Product OverviewProduct Description Cisco 12006 and Cisco 12406 router Front View Product Overview Product Description Product Overview Product Description Cisco 12006 and Cisco 12406 router Rear View Chassis Physical and Functional DescriptionRP and Line Card Slots Alarm Card Slots Switch Fabric Card SlotsChassis Backplane Cooling PowerSwitch Fabric Card Types Multigigabit Crossbar Switch FabricNonredundant and Redundant System Configurations Switch Fabric Redundancy Switch Fabric Switching Capacity and Router TypePower-Up/Down Control Maintenance BusDevice Discovery Environmental Monitoring and Alarms DiagnosticsCode Download Route Processor Functions Route ProcessorsGigabit Route Processor Route Processor TypesProduct Overview Route Processors GRP Layout Type Size Quantity Description Location GRP Memory ComponentsSram System Status LEDs Reset AUX Coll RX Link MIIGRP Alphanumeric LED Displays Partial Faceplate Soft Reset SwitchAsynchronous Serial Ports Pcmcia SlotsEthernet Port Performance Route Processor Front View Performance Route ProcessorProduct Overview Route Processors PRP Horizontal Orientation Sdram PRP Memory ComponentsSdram Flash Disk Size Product Number Soft Reset Switch Ethernet Ports Flash Disk SlotsLine Cards 10 Sample Line Cards Alarm Alarm CardsClock and Scheduler Card and Switch Fabric Card Status Alarm Output FunctionAlarm Card Status Power Source Monitoring Power SubsystemsAlarm Relay Contact Connector AC PDU AC Power Subsystem12 AC Power Distribution Unit 13 AC-Input Power Supply AC-Input Power SupplyProduct Overview Power Subsystems LED Label Function State Description DC Power Subsystem14 DC Power Distribution Unit DC-Input Power Entry Module Power a16 DC-Input Power Entry Module LED Label Color Function Blower Module Power DistributionTop view 18 Air Filter Locations Air FiltersCable-Management System 19 Chassis Cable-Management System Field-Replaceable Units Technical Specifications