CHAPTER 2: INSTALLATION

9.Press down firmly on the back of the BRIM until the pins slide all the way into the connector holes.

Note: Make sure that the standoffs align with the standoff screw holes.

10. Reinstall the coverplate/faceplate screws and standoff screws.

Note: Faceplate and support post screws are provided both on the hub and in the BRIM package.

The BRIM-F6 requires a special 24 pin ribbon connector in addition to the standard 96 pin BRIM connector. This ribbon connector allows the BRIM-F6 to use in-line filtering functionality.

To install the BRIM-F6 ribbon cable:

1.Insert one ribbon cable connector into the ribbon cable jack on the BRIM. (See Figure 2-4.)

Caution: The ribbon cable connector only fits into the ribbon cable jack one way. Fit the tab on the connector into the groove in the jack for correct cable orientation.

2.Press down on the connector until the clips on the jack snap into a vertical locked position.

3.Insert the remaining ribbon cable connector into the ribbon cable jack in the hub.

4.Press down on the connector until the clips on the jack snap into a vertical locked position.

After returning the cover, returning power to your device, and reconnecting to the network, your BRIM-F6 is now ready for operation.

Page 2-8

BRIM-F6 User’s Guide

Image 16
Contents BRIM-F6 USER’S Guide Page Contents Page Chapter Introduction Using This Manual Getting HelpBRIM-F6 Overview BRIM-F6 FeaturesBRIM-F6 Overview Related Documentation Chapter Installation Unpacking the Brim and the FPIMsInstalling the FPIMs Fpim ScrewsInstalling the BRIM-F6 Installing the BRIM-F6Installing a BRIM-F6 into a MIM Brim Tab Installing a BRIM-F6 into a Hub BRIM-F6 User’s Guide Chapter Using Lanview TWR Twisted Ring Chapter Specifications Fiber Optic InterfaceMultimode Receiver Signal Detect Single Mode Specifications Single Mode ReceiverUnshielded Twisted Pair Receiver Signal Detect Cable Specifications Shielded Twisted Pair Transmitter SpecificationsMultimode Fiber Twisted Pair Pinout Configuration Twisted Pair Cable LengthSafety EnvironmentAppendix a Basic Fddi Networks BRIM-F6 User’s Guide A-1Appendix a Basic Fddi Networks Reliability BRIM-F6 User’s Guide A-3Figure A-2. Wrapping a Broken Ring Ansi Standard X3T9.5 BRIM-F6 User’s Guide A-5Figure A-4. Token and Frame Formats BRIM-F6 User’s Guide A-7 Fddi StationFddi Connection Rules Fddi Devices BRIM-F6 User’s Guide A-9Figure A-7. Valid Station Configurations Figure A-8. Duplex Fiber Optic Receptacles and Connectors BRIM-F6 User’s Guide A-11A-12 BRIM-F6 User’s Guide A-13 Bypass State Operational StateFigure A-10. Fddi Devices Design Considerations For Fddi Networks BRIM-F6 User’s Guide A-15Bandwidth Figure A-11. Physical Device Connections BRIM-F6 User’s Guide A-17