Cabletron Systems BRIM-F6 manual Figure A-8. Duplex Fiber Optic Receptacles and Connectors

Page 37

FDDI Devices

FDDI devices physically attach to the ring using Fixed Shroud Duplex (FSD) media interface connectors. The X3T9.5 Physical Layer, PMD standard defines four connector types (see Figure A-7). These connectors provide proper trunk fiber alignment for each of the valid configurations.

Types A, B, and M provide precision connection (i.e., mechanical keying to assure proper connection to Primary-In and Primary-Out fibers). Types A and B allows dual attachment to the primary and secondary data paths of the main ring. Type M allows for single attachment stations, at a concentrator end of the SAS lobe.

The Type S connector has a wide, centrally located, keyway provides non- precision connection (i.e., for SAS lobe attachment).

FDDI RECEPTACLES

FDDI CONNECTORS

PRIMARY IN

SECONDARY OUT

 

TYPE A

Type A

Dual

DUAL

 

 

Attachment

 

 

ATTACHMENT

SECONDARY IN

PRIMARY OUT

TYPE B

 

IN

OUT

 

 

TYPE M

Single

 

 

SINGLE

 

 

ATTACHMENT

 

 

Attachment

IN

OUT

 

TYPE S

Type B

Type M

Type S

Figure A-8. Duplex Fiber Optic Receptacles and Connectors

BRIM-F6 User’s Guide

Page A-11

Image 37
Contents BRIM-F6 USER’S Guide Page Contents Page Chapter Introduction Getting Help Using This ManualBRIM-F6 Overview BRIM-F6 FeaturesBRIM-F6 Overview Related Documentation Unpacking the Brim and the FPIMs Chapter InstallationFpim Screws Installing the FPIMsInstalling the BRIM-F6 Installing the BRIM-F6Installing a BRIM-F6 into a MIM Brim Tab Installing a BRIM-F6 into a Hub BRIM-F6 User’s Guide Chapter Using Lanview TWR Twisted Ring Fiber Optic Interface Chapter SpecificationsMultimode Receiver Signal Detect Single Mode Receiver Single Mode SpecificationsUnshielded Twisted Pair Receiver Signal Detect Shielded Twisted Pair Transmitter Specifications Cable SpecificationsMultimode Fiber Twisted Pair Cable Length Twisted Pair Pinout ConfigurationEnvironment SafetyBRIM-F6 User’s Guide A-1 Appendix a Basic Fddi NetworksAppendix a Basic Fddi Networks BRIM-F6 User’s Guide A-3 ReliabilityFigure A-2. Wrapping a Broken Ring BRIM-F6 User’s Guide A-5 Ansi Standard X3T9.5Figure A-4. Token and Frame Formats Fddi Station BRIM-F6 User’s Guide A-7Fddi Connection Rules BRIM-F6 User’s Guide A-9 Fddi DevicesFigure A-7. Valid Station Configurations BRIM-F6 User’s Guide A-11 Figure A-8. Duplex Fiber Optic Receptacles and ConnectorsA-12 Bypass State Operational State BRIM-F6 User’s Guide A-13Figure A-10. Fddi Devices BRIM-F6 User’s Guide A-15 Design Considerations For Fddi NetworksBandwidth BRIM-F6 User’s Guide A-17 Figure A-11. Physical Device Connections