Cabletron Systems SmartCell 6A000 manual 8000, 5000

Page 53

Switch Administration

Traffic Management

SmartCell 6A000 user data cells are classified according to the state of a cell loss priority (CLP) bit in the header of each cell. A CLP 1 cell has a lower priority than a CLP 0 cell, and is discarded first. Source traffic descriptors can specify CLP 0 cell traffic, CLP 1 cell traffic, or the aggregate CLP 0+1 traffic.

Use the trafficdescriptor commands to view, create, and delete traffic descriptors.

For example, enter the show trafficdescriptor command to view all currently defined traffic descriptors.

SmartCell ZX# show trafficdescriptor

 

 

 

 

 

TD# Traff

Desc

QoS

Peak Cell Rate

Sust Cell Rate

Max Burst

Size

Aal

VC

Type

Type

 

(Kb/s)

(Kb/s)

(Kb)

 

Type

Type

 

 

 

CLP_0 CLP_0+1

CLP_0 CLP_0+1

CLP_0 CLP_0+1

 

 

============================================================================

1

UBR

8

4

0

34

0

0

0

0

5

PVC

2

NRTVBR

2

1

0

1372

0

0

0

0

5

PVC

3

CBR

3

1

500

1000

0

0

0

0

3

PVC

4162

UBR

8

0

0

138889

0

0

0

0

5

SVC

7632

UBR

8

0

0

138889

0

0

0

0

5

SVC

7661

UBR

8

0

0

138889

0

0

0

0

5

SVC

7983

UBR

8

0

0

138889

0

0

0

0

5

SVC

8046

UBR

8

0

0

138889

0

0

0

0

5

SVC

11642 UBR

8

0

0

138889

0

0

0

0

5

SVC

SmartCell ZX#

 

 

 

 

 

 

 

 

 

 

The Descriptor Type parameter in the example above corresponds to the traffic descriptor types defined in the UNI3.0/UNI3.1specification. Descriptor types are specified numerically and are as follows:

1 = No Traffic Descriptor

2 = Traffic Descriptor with no CLP and no SCR

3 = Traffic Descriptor with CLP, no Tagging, and no SCR

4 = Traffic Descriptor with CLP, Tagging, and no SCR

5 = Traffic Descriptor with no CLP and SCR

6 = Traffic Descriptor with CLP, no Tagging, and SCR

7 = Traffic Descriptor with CLP, Tagging, and SCR

8 = Traffic Descriptor with CLP and best effort

PVCs can use user-defined traffic descriptors. For instance, if a video link over a PVC requires a constant data flow of 5000 kb/s and a peak cell rate of 8000 kb/s, create a traffic descriptor for CBR traffic that specifies 5000 as the sustained cell rate and 8000 as the peak cell rate.

SmartCell ZX # add trafficdescriptor

 

TrafficType(UBR)

: CBR

TrafficDescriptorType(8)

: 3

PCRCLP01(0)

: 8000

PCRCLP0(0)

:

SCRCLP01(0)

: 5000

SCRCLP0(0)

:

MBSCLP01(0)

: 10000

MBSCLP0(0)

:

QOSClass(1)

:

AALType(5)

:

SmartCell ZX #

 

SmartCell 6A000 User Guide 4-19

Image 53
Contents Order number Part number 04-0045-01 Rev. a SmartCell 6A000 User GuideIi SmartCell 6A000 User Guide FCC Class a Notice Declaration of Conformity Addendum Safety Information Class 1 Laser Transceivers Fiber Optic Protective Caps Regulatory Compliance Summary Safety Revision History Table of Contents Troubleshooting Acronyms Index Table of Contents Xii SmartCell 6A000 User Guide List of Figures List of Figures Xiv SmartCell 6A000 User Guide List of Tables List of Tables Xvi SmartCell 6A000 User Guide Introduction Introduction SmartCell 6A000 User Guide Unpacking the Switch Switch Installation and SetupInspecting the Switch Check Accessory Carton Contents6A000-04 and 6A000-02 front panels Mbps STS-3c/STM-1 UTP5, 4 Ports Installing the SwitchInstalling the Switch Installing the SmartCell 6A000 Adapters provided for connecting to the switch Configuring the Switch6A000 console and network connections Console Commands Using the ConsoleEnter Adding and ModifyingClient UNIATMAddress 390000000000000000001441800020d414418000 Console HelpServerAddress 390000000000000000001441800020d414418001 Creating AN IP Over ATM Vlan IP Over ATM and LaneIpatmarp ATM Addressing for IP over ATMSmartCell ZX # add wellknownaddress Creating AN Emulated LANELANType802.3 The default Ethernet is used ATM Addressing for LAN Emulation Elan1 ELANs Across Multiple SwitchesSwitch Clients Path /backdir/config-1 Switch AdministrationBacking UP and Restoring Switch Configuration Path server.ima Upgrading Operating SoftwareUsing the df Command to Recover Setting UP RoutesUnsuccessful Update Creating Iisp Routes Iisp RoutingSmartCell ZX # show netprefix a4 ATMAdress 39000000000000000000144780 SW2s netprefixATMAdress 39000000000000000000144180 SW1s netprefix Iisp Routes Among Multiple SwitchesATMAdress 39000000000000000000141500 SW3s netprefix Iisp routes between multiple switches Default Iisp RoutesIisp Routes and Network Topology For example, create a default Iisp route from port B1Routing Loops 112255 112244UNI Routes SigConfig and PortAutoDetect with Iisp RoutingIisp Metrics and Load Sharing UNIATMAddress 440000000000000000001441800030E514418000IP Routing To see the route, enter the show route command on SW2 Logs and AlarmsViewing and Filtering Messages How Log Messages and Alarm Messages DifferLog Message System Console Setting UP PVC ConnectionsPoint-to-Point PVCs Connecting to Local Client Through Point-to-Point PVC100 10.1.1.0Point-to-Multipoint PVCs Show vccmask Non-zero VPIsSmartCell ZX # show portconfig a1 SmartCell ZX # set portconfig a1Traffic Descriptors Traffic Management5000 8000Call Admission Control Policy # set cacparams Class of Service QueuesPortNumberALL Port ID Queue EFCI, EPD, and RM Thresholds Class of Service Queue Allocation GuidelinesSmartCell ZX # show switchtrafficcongestion Traffic Management Logprint off command TroubleshootingTroubleshooting IP Over ATM Troubleshooting LAN Emulation Global Congestion Troubleshooting CongestionDiagnosing Congestion Port Congestion Troubleshooting TroubleshootingCongestion Troubleshooting Congestion Front Panel Appendix a Features and SpecificationsHardware Components Figure A-1 Front panel CPU ModuleInput/Output Port Modules Switch Modules MSM and ESMModule TypeCharacteristics Figure A-3 Group and port identifiers Port NumberingSwitch Module FeaturesSignaling and Routing 3 I/O ModulesLAN Servers and Clients Connection ManagementManagement ATM Forum LAN Emulation LanePhysical Specifications SpecificationsTechnical Specifications Standards Specifications ATM Port SpecificationsRJ-45 DB-25 Pin Color Description CPU Serial Port Pin-Out DescriptionsTable A-11 RJ-45 to DB-25 Adapter Modem Adapter Appendix A-12 SmartCell 6A000 User Guide Internet MIB Hierarchy Appendix B Smartcell 6A000 and SnmpFigure B-1 Internet MIB Hierarchy Zeitnet Proprietary MIBFigure B-2 ZeitNet Private MIBs Interpreting the Object IdentifierProprietary MIB Functions Client for Snmp Management Console Commands That Affect the AgentMIB Exceptions Non-ConformanceNot Supported SmartCell 6A000 User Guide Appendix B-7 Page Electronic Services FAX ServiceAppendix C Technical Support Telephone AssistanceRepair Services Hardware WarrantySoftware Warranty Appendix D Acronyms Can CACCBR CcittDTE DCCDVT NETFifo FCSFTP IeeeIP/ATM IOMIPX ITU-TSSLeselan LESLIS LLCNFS NetbeuiNIC NLSPMD PDUPMP PPDSAR SaalSAR-PDU SBETCP TaxiTDM TftpVCI VCCVCL VlanAcronyms Appendix D-12 SmartCell 6A000 User Guide Index Add wellknownaddress command 3-6 AddressSetting up routes Vlan Index SmartCell 6A000 User Guide