Cabletron Systems 3H08-04 Diagnostic Results, Troubleshooting, If the Module Fails to Power Up

Page 29

Diagnostic results

For both types of tests, normal operation is indicated when generated packets are received back (after looping) without errors. For remote loopback tests, the ATX creates LLC Type 1 test packets for LANs and PPP echo-request packets for WANs and UARTs.

To start both types of loopback tests, use the NMS. When you use the NMS for these tests, the results are reported back to the NMS.

5.4 DIAGNOSTIC RESULTS

ATX diagnostic results are indicated in two ways: by looking at the front panel LEDs (which are explained later in this chapter) or by reading NMS trap messages. Both power-up and loopback diagnostics produce traps, which are sent to the NMS and may be logged for future reference. Although you might find it more convenient to just watch the LEDs, in most cases traps provide more information. There are no LEDs for the loopback tests–the results of these tests must be observed (i.e., accurate packet transmission) or read using an NMS (i.e., examine traps).

5.5 TROUBLESHOOTING

5.5.1 If the Module Fails to Power Up

If the FE Switch Modules fail to power up when the ATX is on and functioning properly:

1.Check the status of ports using Local Console Manager.

2.Reset the switch module and watch the power-up sequence again.

3.If the sequence is still abnormal:

a.Remove the interface module by unscrewing the two retaining screws on the module front panel.

b.Carefully, but firmly, press down on all socketed components.

c.Re-install the module. Make sure the module is properly seated and tighten the retaining screws.

d.Reset the ATX and observe the power-up sequence.

4.If it is still abnormal, contact Cabletron Systems Technical Support.

FE Switch Module User Guide

Page 5-3

Image 29
Contents User Guide Fast Ethernet Switch ModulePage FE Switch Module User Guide FCC Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Contents Contents FastNET ATX Chapter IntroductionUsing this Manual Overview 3H02-04 FE Switch Module3 Offline Button ConnectorsLEDs 3H08-04 Front Panel 3H08-04 FE Switch ModuleDocument Conventions Getting Help Related ManualsFE Switch Module User Guide POWER-UP LED Sequence Chapter Connecting to the NetworkConnecting the 3H02-04 FE Switch Module Connecting to a Network3H08-04 Front Panel Connections Connecting the 3H08-04 FE Switch ModuleFE Switch Module User Guide Chapter Configuring Local Console Manager Commands Connecting the Local Console ManagerChapter Monitoring Displaying Switch Module Port StatusMonitoring Displaying Switch Module Port Status Monitoring FE Switch Module User Guide POWER-UP Results Chapter Diagnostics and TroubleshootingPOWER-UP Tests Diagnostics and Troubleshooting Operational DiagnosticsIf the Module Fails to Power Up Diagnostic ResultsTroubleshooting Connectivity Problems Chapter ADDING/SWAPPING Modules Unpacking the Switch ModuleAdding a Switch Module Swapping a Switch Module Swapping a Switch Module FE Switch Module User Guide TCP/IP IPX Appendix a Technical Specifications3H02-04 RJ45 for UTP 3H08-04 ST for Fiber Optics Appendix B Cables TYPES/CONNECTORSCable Specifications Fast Ethernet PIN Assignments About RJ45 ConnectorsFast Ethernet Pin Assignments Crossover Wiring for the 3H02-045 Definitions Straight-Through Wiring for the 3H02-04Limitations & Restrictions Index Index Index-2 FE Switch Module User Guide