Cabletron Systems 9H42X-XX manual Configuring Duplex Modes

Page 106

Bridging

To delete an address:

1.Click to highlight the address entry in the Address Entry panel that you wish to delete from the filtering database.

2.Click on .

Clearing All Permanent, Static, or Dynamic Entries

To erase all Permanent, Static, or Dynamic entries from the Filtering Database,

click on the associated button in the upper portion of the window.

Configuring Duplex Modes

WARNING

Any standard Ethernet interface on a 9H42x-xx module which is connected to another end station — i.e., another bridge interface — will support Duplex Mode operation. (Ethernet interfaces connected to repeaters will not support this mode.) Enabling Full Duplex mode on an interface allows the interface to receive and transmit packets at the same time, effectively doubling the available bandwidth (and, therefore, the wire speed) on the selected interface. Interfaces which are not set to Full Duplex mode must receive and transmit separately, waiting for one activity to be completed before the other is begun.

For standard Ethernet interfaces, Full Duplex should only be enabled on an interface that has a connection to a single destination address at the other end of the connection (i.e., it is not a segment with an attached repeater cascading the connection to multiple destination addresses).

Full Duplex mode disables the collision detection circuitry at the interface, so that both Transmit and Receive wires can be used simultaneously. With a single destination address at the other end of the connection (for example, if the connection was to a full duplex interface on another switching module, or if a single file server was connected to the full duplex switch port), this essentially doubles the available bandwidth from 10 Mbit/sec to 20 Mbit/sec. Note that the interface at the other end of the connection must also have Full Duplex enabled at the attached interface.

Full Duplex mode must be disabled if the interface is communicating with multiple destinations simultaneously (i.e., if a repeater is cascaded from the interface), since Ethernet relies on Collision Sense for proper operation.

You can configure the duplex mode for each appropriate interface via the Duplex Modes window accessible from both the Module View and Bridge Status window Bridge menus, and via the Port Configuration window accessible from both the Module View and Bridge Status window Port menus. From the Bridge menus, a single window allows you to both display and set the configuration of each

Configuring Duplex Modes

5-25

Image 106
Contents Cabletron Systems Virus Disclaimer Page Restricted Rights Notice Page Contents Chapter Statistics Chapter BridgingIndex Contents Viii Introduction Introduction Using the 9H42x-xx User’s Guide Software Conventions Related ManualsCommon 9H42x-xx Window Fields Location Device NameIP Address MAC AddressUsing On-line Help Using ButtonsGetting Help 9H42x-xx Firmware Getting Help from Cabletron Systems’ Global Call CenterIntroduction 9H42x-xx Firmware 9H42x-xx Module View From an individual device iconViewing Module Information From the MMAC-Plus Chassis ViewUp Time Front Panel InformationConnection Status Port StatusFirmware Boot PromMenu Structure TimeH42x-xx Module View Menu Structure Device MenuPort Status Menu Utilities MenuHelp Menu Bridge MenuPort Status Displays Port MenuSelecting a Port Status View StatusLoad ErrorsMapping Type Chassis Manager WindowSpeed Port Status Color CodesViewing the Device Type Chassis Manager Window To view the Chassis Manager windowUpTime Viewing I/F Summary InformationIndex Interface Performance Statistics/Bar Graphs DescriptionSta Raw CountsRate Viewing Interface Detail AddressNon-Unicast ErrorUnicast DiscardedPackets Transmitted Transmit only Using the Find Source Address FeatureMaking Sense of Detail Statistics Managing the Module Configuring PortsConfiguring Standard Ethernet Ports Standard ModeFull Duplex Configuring Fast Ethernet Ports Fast Ethernet ConfigurationPort Type Current Operational ModeDesired Operational Mode Link StateAdvertised Abilities Remote CapabilitiesSetting the Desired Operational Mode Setting the Device Date and Time 10. Edit Time WindowEnabling and Disabling Ports 11. Edit Date WindowTo enable or disable bridging for an individual interface 9H42x-xx Module View Managing the Module Alarm Configuration About Rmon Alarms and EventsBasic Alarm Configuration Alarm ConfigurationAccessing the Basic Alarm Configuration Window Rmon Basic Alarm Configuration WindowPort Number Viewing Alarm StatusKilobits Total Errors Broadcasts/Multicasts If NumberRising Threshold Log/TrapPolling Interval Rising ActionCreating and Editing a Basic Alarm Alarm Configuration Alarm Configuration Disabling a Basic Alarm Viewing the Basic Alarm LogAlarm Configuration Advanced Alarm Configuration Accessing the Rmon Advanced Alarm/Event ListAlarm Configuration Such as the Hosts component, not present, or Creating and Editing an Advanced Alarm Rmon Create/Edit Alarms WindowAlarm Configuration Alarm Configuration Alarm Configuration Table index.lengthin bytes.instancein decimal format Alarm Configuration Creating and Editing an Event Rmon Create/Edit Events Window Alarm Configuration Adding Actions to an Event Rmon Create/Edit Actions Window Or deleted use the button to update the table at any time Deleting an Alarm, Event, or Action Viewing an Advanced Alarm Event LogHow Rising and Falling Thresholds Work Event Accessing the Statistics Windows StatisticsTot. Errors Rmon StatisticsPackets ProblemsBytes Drop EventsFrame Size Bytes Packets Viewing Total, Delta, and Accumulated Statistics Interface Statistics Printing StatisticsInterface Statistics Window Unicast Bridging Bridging BasicsAn Overview of Bridge Management More on Transparent BridgingBridge Status Window Spanning Tree State Bridge Address Interface TypeInterface Speed Enabling and Disabling Individual Interfaces Enabling and Disabling All Installed InterfacesEnabling and Disabling Bridging From the Bridge Status windowBridge Statistics Performance GraphsForwarded Green Xmitted Blue Total Errors RedFiltered Magenta Configuring the Bridge Performance GraphsUsing Source Addressing Altering the Ageing TimeBridge Spanning Tree Viewing Spanning Tree Parameters Bridge Spanning Tree WindowRoot Bridge Bridge-level ParametersBridge Priority Root CostHello Time Forwarding DelayProtocol Max AgePort-specific Parameters Topology Changing Bridge Spanning Tree ParametersDesignated Port Changing Bridge PriorityChanging Hello Time Changing the Spanning Tree Algorithm Protocol TypeChanging Max Age Time Changing Port Priority Changing Forwarding Delay TimeChanging Path Cost Filtering Database Dynamic, or LearnedFiltering Database Window Capacity ListNumber Ageing TimeReceive Port Configuring the Filtering DatabaseSource Port Port FilteringChanging the Type of Entry Changing the Receive PortChanging the Port Filtering Action Adding or Deleting Individual EntriesConfiguring Duplex Modes Clearing All Permanent, Static, or Dynamic EntriesTo access the Duplex Modes window Bridging Bridging Configuring Duplex Modes Index NumericsIndex-2 Index-3 Index Index-4

9H42X-XX specifications

Cabletron Systems 9H42X-XX is an advanced networking device recognized for its robust performance and reliability in various enterprise environments. Designed to meet the growing demands of data communication, this model serves as a vital component of network infrastructure, offering a myriad of features and technologies.

One of the standout characteristics of the 9H42X-XX is its high-speed data processing capabilities. Equipped with multiple Gigabit Ethernet ports, it ensures rapid data transfer rates, making it ideal for bandwidth-intensive applications. This model supports both IPv4 and IPv6 addressing, ensuring compatibility with modern networking standards and future-proofing the investment for organizations transitioning to newer technologies.

The 9H42X-XX excels in flexibility and scalability, accommodating a range of networking topologies. Its modular design allows for the addition of different interface cards, catering to specific networking requirements such as VoIP, video streaming, and cloud services. This adaptiveness is crucial for organizations that must optimize their network as needs evolve over time.

Security is a primary consideration in the design of the 9H42X-XX. With built-in firewall capabilities and support for advanced encryption protocols, data integrity and confidentiality are ensured. Furthermore, the device offers robust access control features, allowing organizations to define user permissions and protect sensitive information from unauthorized access.

Another important feature is the comprehensive management options available with the 9H42X-XX. It provides a user-friendly interface for network administrators to monitor traffic, configure settings, and troubleshoot issues. This ease of management contributes to reduced downtimes and better overall network efficiency.

Additionally, the Cabletron Systems 9H42X-XX is known for its durability and performance consistency in varying environmental conditions. This resilience makes it suitable for both indoor and outdoor deployments, further extending its usability across different types of organizations.

In summary, the Cabletron Systems 9H42X-XX is a versatile networking solution that combines high-speed connectivity, security features, and ease of management within its robust architecture. Its adaptability and technical specifications position it as a reliable choice for enterprises looking to upgrade their network infrastructure and accommodate future growth.